TECHNICAL DOCUMENTATION
SSP 262 Natural gas an alternative fuel for motor vehicles

This PDF is currently unavailable.
Read document text
Service TrainingSelf-study programme 262Natural gas - an alternative fuel for motor vehiclesDesign and functionWithin the process of reducing harmful emissions caused by traffic in built-up cities and the rising costs of petrol and diesel fuel, more emphasis is being placed on natural gas as an alternative power source to drive motor vehicles. Gas as a power source to drive vehicles is not a modern invention. It has a long history. Even the first internal combustion engine - the patent for which was applied for by Nikolaus Otto in 1876 was developed in the Deutz AG gas engine factory. Within the scope of further motor vehicle engine development, gas technology, as well as other drive concepts, was always a source upon which engineers could fall back on - mostly in times of emergency. This lead to vehicles being equipped with storage tanks, in which town gas or a mixture of propane/butane was filled, or the gas was generated directly in gas generators from wood or anthracite while the vehicle was in motion.In this day and age, Volkswagen offers the Golf BI FUEL as a series production vehicle with bivalent natural gas drive (vehicle can be driven with natural gas or petrol). The Transporter ’91 ➤ can be equipped with a retrofit option for bivalent natural gas powered operation. Please note that there will be country-specific differences with regards to legal requirements. With this self-study programme we would like to introduce you to the special features of the bivalent natural gas drive system for Volkswagen vehicles (centred around the framework conditions in Germany).S262_012NEWWarning NoteThe self-study programme represents the design and function of new developments! The contents will not be updated.For instructions on testing, adjusting and repairs, please refer to the relevant service literature.2At a glanceIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Natural gas. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Natural gas compared with other fuels. . . . . . . . . . . . . . . . . . . . . . . . . 8 Supply of natural gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Comparison and laws affecting its use . . . . . . . . . . . . . . . . . . . . . . . . . 14Engine technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16The Transporter ‘91 ➤ bivalent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 The Golf BI FUEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Natural gas storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20The different methods of storing natural gas fuel. . . . . . . . . . . . . . . . 20 The gas tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 The tank test intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Natural gas components in Golf BI FUEL . . . . . . . . . . . . . . . 26Overview of components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Natural gas supply in Golf BI FUEL . . . . . . . . . . . . . . . . . . . . 28System overview of natural gas supply . . . . . . . . . . . . . . . . . . . . . . . . 28 Flow chart of natural gas supply system . . . . . . . . . . . . . . . . . . . . . . 30 High pressure side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 From high pressure to low pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 The low pressure side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 The technical safety concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Engine management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54The system overview of sensors and actuators . . . . . . . . . . . . . . . . . The system functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The function chart, Transporter ‘91 ➤ bivalent . . . . . . . . . . . . . . . . . The function chart, Golf BI FUEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 56 62 64Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66The legal requirements in Germany . . . . . . . . . . . . . . . . . . . . . . . . . . 66 The diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Associated special tools and workshop equipment . . . . . . . . . . . . . . 70Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Explanation of highlighted termsTest your knowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 763IntroductionNatural gasAt the start of the 90s, public interest was centred more and more around motor vehicle traffic as the main cause of pollution and excessive noise in built-up cities. Only terms such as “summer smog” and “acid rain” are referred to. For the emissions of gas components nitrogen oxide (NOx), hydrocarbons (HC), carbon monoxide (CO), carbon dioxide (CO2) and soot particles, strict limit values were established. The use of alternative fuels, such as natural gas, makes an effective contribution towards improving the environmental situation. Natural gas is created under similar conditions to that of oil and is produced as a by-product of oil extraction. It is also found in single geological deposits. It is lighter than air and mixes well with the air. It burns “softly”. As a flammable gas, natural gas is the most environmentally compatible fossil energy source. It comprises in essence of 80 - 99 % methane (CH4). The rest is built up of carbon dioxide, nitrogen oxide and low value hydrocarbon additions. The lower the carbon content of an energy source, the lower the carbon related emissions, such as carbon dioxide, carbon monoxide and soot particles. Natural gas can be used as a fuel directly in internal combustion engines without any chemical changes necessary. In this way, there is a considerable saving in costs compared to the measures necessary in processing oil to petrol and diesel. However, it may be necessary to clean or dry the natural gas depending on the source from which is was extracted. The availability of natural gas resources is greater than that of mineral oil. This way there is a means of interchanging the exclusive dependence on oil. For reasons of safety, the odourless natural gas is supplemented with strong smelling additives in Germany. This makes it possible to detect natural gas by smell even in the smallest of quantities.S262_0254Number of gas powered vehicles The number of gas powered vehicles was calculated using international natural gas powered vehicle statistics, as of the second half of 2003.Number of gas powered vehicles world-wide approx. 2,837,000S262_054The number of vehicles world-wide is currently about 665 million. Approx. 2.8 million of these are registered as natural gas powered vehicles. The leading countries here are those with high natural gas deposits, such as Argentina with approx. 951,000 gas powered vehicles.In Europe, Italy is way ahead of other countries with 434,000 vehicles, thanks to a good natural gas infrastructure. In Germany, currently about 20,000 vehicles run on natural gas. Half of these are Volkswagen models which were specially converted for this purpose.5IntroductionRaw natural gas The term natural gas includes all gaseous hydrocarbon compounds that originate from the earth and are flammable. Like oil and coal, natural gas belongs to the group of natural, flammable organic raw materials. The main element of natural gas is methane – a chemical composition of hydrocarbon and hydrogen. It can be used in engines without further processing. The number of natural gas deposits that were created over millions of years and are stored by natural means are enormous by comparison. If the current amount extracted per year is maintained, the world-wide reserves of natural gas known to man will last 2 and a half times longer than the oil reserves. Due to the fact that sources can be found all over the world, the dependence on individual countries for supply is low.Countries that supply natural gas to Germany 19 % Holland 35 % Russia 5 % Denmark/Great Britain20 % NorwayOwn supply 21 %S262_055Do not confuse natural gas with: LPG (Liquefied Petroleum Gas), also known as auto gas or liquid gas; comprises mostly of propane and butane. It is created as a by-product of petrol production and is therefore directly dependent on the oil reserves.6Qualities of natural gas Natural gas deposits can be found, for example, in the north of Germany, in the Netherlands, in the North Sea, in Norway and in Russia (a main producer and supplier to Germany). Different qualities of natural gas are offered depending on the natural gas supplier. With an increase in the network of natural gas suppliers, a mixture of the individual qualities will be offered as a composite gas. Qualities of natural gas in Germany: The difference in quality is based on the calorific value of the natural gas. Depending on the calorific value, a differentiation is made between H gas (high) and L gas (low). The different calorific values of H gas and L gas result in different fuel consumption figures.Monthly average figures for purposes of orientation regarding different gas qualities North Sea H gas Calorific value Methane [kWh/m3] 11.1 87.1 10.9 2.5 0.5 (CH4) [Vol. %] (C2H6) (C3H8) [Vol. %] (C4H10) (N2) [Vol. %] Russia H gas 10.0 97.8 1.3 0.8 0.1 Germany L gas 8.9 86.8 6.7 2.7 1.0 Germany (Uelzen) L gas 8.2 79.8 1.8 17.6 0.8Ethane Propane ButaneNitrogenCarbon dioxide (CO2) [Vol. %]North SeaGermany (Uelzen)RussiaGermanyS262_0567IntroductionNatural gas compared to other fuelsExhaust emissions The chart shown below shows the reduction of exhaust gas emissions for a light commercial vehicle in comparison between a natural gas and petrol powered engine. Reduction in emissions with natural gas operation Emissions test on light commercial vehicle with 2.5 l/85 kW petrol engine in European driving cycle.Relative harmful emissions (%)CO Carbon monoxideNOx Nitrogen oxides PetrolHC HydrocarbonsCO2 Carbon dioxideNatural gasS262_016a8Comparison of non-limited emissions The chart below shows the reduction in exhaust gas emissions for non-limited exhaust gas components, using a light commercial vehicle as an example, with diesel, petrol and natural gas operation compared against each other.Relative harmful emissions (%)BTXFormaldehyde DieselAromaticsPAKOlefineNMOG PetrolBenzoldehydeNatural gasS262_017aNon-limited exhaust gas components are:BTX - Benzene, toluol and xylene Aromatic carbon compounds, solvents Formaldehyde Disinfectant, pungent smelling gas Aromatics Benzol compoundsPAK Polycyclic aromatic hydrocarbons Olefin - Unsaturated, chain-like hydrocarbons NMOG - No methane organic gases. The sum of all hydrocarbons, excluding aromatic compounds. Benzoldehyde - Short lived by-products of aromatic compounds9IntroductionObservations regarding the economy The costs play a decisive role in the acceptance and spread of natural gas powered vehicles. Significant criteria for procurement of a natural gas powered vehicle are: – More environmentally friendly system compared to diesel or petrol engines – The amortisation period for the additional price on procurement – The fuel costs – Reduced road taxes – Local financial benefits from gas suppliers – Local exclusion from restricted access zones where traffic causes smog, for example – The tank filling station network The cost of buying a natural gas powered vehicle is higher than that of a similar vehicle with petrol or diesel engine. To calculate the amortisation period, an average additional price of 2,500 Euro was used, with consideration given to the possible promotion schemes. The advantage in price comes from the lower fuel costs with natural gas operation.Amortisation period of natural gas system compared with petrol versionA price advantage of 5.90 Euro/100 km was used in the example.Amortisation period (years) 43Price advantage 5.90 Euro/100 km15,000 km/year 2 30,000 km/year 1S262_0205.00 10.00 EuroPrice advantage - natural gas/petrolDepending on the annual mileage, amortisation periods of under 2 years up to a maximum of 4 years are calculated.10Amortisation period of natural gas system compared with diesel version A price advantage of 3.20 Euro/100 km was used in the example.Comparison with a diesel version results in a longer amortisation period due to the lower price difference (diesel/natural gas).On the diesel version, the amortisation period is between 3 and 7 years, depending on the annual mileage.Amortisation period (years) 9 8Price advantage 3.20 Euro/100 km7 6 5 4 3 2 1 2.50 3.50 4.50 Euro 30,000 km/year 15,000 km/yearS262_021Price advantage - natural gas/dieselThe amortisation period is shortened if: • the difference in fuel prices (natural gas to petrol/diesel) rises, • the annual mileage increases, • the purchase price for a natural gas powered vehicle drops.11IntroductionThe supply of natural gasNatural gas filling station network in Germany At the start of 2004, the natural gas filling station network comprised of over 400 stations. By the year 2007, there will be approx. 1000 natural gas filling stations. A list of the natural gas filling stations in Germany - in order of area code - can be called up by fax. The first number of the respective area code must be placed at the end of the fax number when doing this. Example: Dusseldorf area code 4....) Fax number: 0190- 516 169 6284EuropeS262_019aThere are natural gas filling stations in almost all European countries. A filling station network has been started in the north of Spain. With the exception of Italy, the same standardised filling connection (as that used in Germany) is used in all other countries. If travelling in Italy, it is advisable to carry an adapter in the vehicle.S262_121Adapter for Italian filling connectionFurther information, including addresses of natural gas filling stations, can be obtained by calling (0180 2 23 45 00) at the local rate, at any time day or night. This information and more can be found on the internet at www.erdgasfahrzeuge.de and www.gibgas.de.12RefuellingFilling connection on vehicleThe procedure for refuelling is based on the TK15 type of tank coupling.NozzleRefuelling is as simple, safe and fast as for other types of fuel. 1st step: Take nozzle out of pump and set lightly on the filling connection of the vehicle; 2nd step: Filling lever on nozzle should be turned 180° in clockwise direction; When doing this, the nozzle is locked on the filling connection at the same time to allow the refuelling process to commence; 3rd step: Refuel by pressing the start button on the pump; When the maximum tank pressure is reached the refuelling process is stopped. Refuelling can be stopped at any time by pressing the stop button on the pump; 4th step: Once refuelling has been stopped, turn back filling lever 180° in anti-clockwise direction. This results in nozzle and gas line pressure being reduced automatically by means of ventilation, and the lock is released; 5th step: Remove nozzle from filling connection of vehicle and place back in pump;4th step 1st step2nd step3rd step5th stepS262_033The weight of natural gas is calculated directly in relation to the volume and therefore the amount filled is shown in kilograms. One kilogram of natural gas has a volume of approx. 6.2 litres.13IntroductionComparison and laws affecting the use of gasThe following compares the advantages and disadvantages of using natural gas as a fuel:Advantages: • A cheap and little used source of energy for those who travel regularly • Low mineral oil tax rate fixed until the end of 2020 across Germany • Promoted in varying degrees regionally by communities and natural gas suppliers (e. g. by loans, refuelling vouchers or contribution towards conversion costs) • Harmful emissions considerably lower than petrol and diesel fuel • Combustion results almost completely in water • Can be used in conventional petrol engines without chemical change • Well suited for bivalent use • High resistance to knocking • No change in insurance • Deposits of natural gas will last considerably longer than raw oil • No loss through vaporisation when refuelling • Lighter than air, evaporates upwards • Environmentally friendly thanks to low harmful emissions • Burns more “softly” • Emissions almost completely free of particulatesDisadvantages: • Compared with petrol operation, a reduction in engine performance if optimised petrol engine is kept • Special installation, safety and monitoring regulations have to observed due to the high pressure tanks • The additional fuel volume for bivalent operation must be accommodated on the vehicle • The natural gas tanks made from steel are an additional load on the vehicle, whereby plastic tanks do not cause this problem • Currently, the filling station network in Germany is not very dense, though as of 2004 there are more than 400 stations • Higher purchase price • Special inspections (vehicle/technical testing) of natural gas tanks necessary at additional cost every 3 to 10 years, depending on design • Low range if vehicle is powered by gasS262_01414Legal requirements currently applicable in Germany The StVZO (road traffic and vehicle registration act) applies in Germany for registration, periodical testing and vehicle modification measures. For gas powered vehicles, there are additional regulations ...– with regards to motor vehicle emissions The use of natural gas helps to reduce the negative impact on the environment from exhaust gas emissions, which are controlled by strict regulations. As of 01.01.2000, emissions have to fulfil the EU III standard. Once the EU IV standard comes into force in 2005, there will be an even greater restriction on emissions. Until then, tax benefits can be gained for vehicles that already fulfil the EU IV emissions standard. A vehicle that has been converted for use with natural gas is also entitled to these tax benefits until 2005, providing it fulfils the EU III/D4 standard.– with regards to natural gas The following guidelines apply for conversion, testing, operation and registration of natural gas powered vehicles. Guideline 757 of the VdTÜV (association of vehicle and technical testing centres) EN13423 Handling of natural gas powered vehicles ECE-R110 ECE-R115 Safety data sheet G609 from the DVGW (German organisation for gas and water trades) GSG (law on equipment safety) Pressurised container regulations Further information regarding legal requirements can be found in the chapter entitled “Glossary”.The legal requirements currently applicable in Germany are being revised by the Federal Ministry of Transport, Construction and Housing. Among other things, the revision is designed to establish the following two points: – Maximum period of use for natural gas tank: 20 years – Natural gas system to be inspected every 36 months for suitability by natural gas vehicle specialist The final version of the revised legal requirements was unavailable at the time of publication.Work on the high pressure side of the natural gas system should only be carried out by trained specialists with special certificate of trade proficiency.15Engine technologyThe Transporter ‘91 ➤ bivalentThe Transporter ‘91 ➤ with petrol engine 2.5 l/85 kW (engine code AET) can be converted for bivalent operation with a natural gas system. Bivalent operation means that the vehicle can be run on petrol and also natural gas. Bivalent operation is made possible by conversion of the components specific to natural gas in addition to the components for petrol operation. Changing over from one type of fuel to the other is either automatic or via an operating mode changeover switch, which is actuated by the driver. Combustion chamber and ignition system stay as standard on the bivalent version. Adaptations are made, with regards to the fuel used, in the engine management system, the maps and the lambda probes. Unlike the Golf BI FUEL, an additional control unit is installed on this type of vehicle for natural gas operation. Bivalent steel tanks are used to store the natural gas on the Transporter ‘91 ➤.S262_05716Technical data: Transporter ‘91 ➤ bivalent Engine code Capacity Engine type Valves per cylinder Bore Stroke Compression ratio Engine management Maximum output: Petrol Natural gas (H gas) Maximum torque: Petrol Natural gas (H gas) Fuel Exhaust gas treatment Emissions standard: Petrol Natural gas (H gas) AET 2.5 l 5-cylinder in-line engine 2 81.0 mm 95.5 mm 10.0 : 1 Petrol: Simos 5S Natural gas: Metatron 85 kW at 4500 rpm 78 kW at 4500 rpm 200 Nm at 2200 rpm 190 Nm at 3300 rpm Petrol with 95 RON / natural gas Exhaust gas recirculation; catalytic converter EU III commercial vehicles EU III commercial vehiclesComparison between petrol and natural gas: Transporter ‘91 ➤ bivalent Output TorquePetrol PetrolH gasOutput kWH gasTorque NmEngine speed (rpm)Engine speed (rpm)S262_038S262_03917Engine technologyThe Golf BI FUELThis vehicle is offered exclusively with the 2.0 l/85 kW engine (engine code BEH). In the Golf BI FUEL, only one Motronic control unit is installed for both modes of bivalent operation and there are optimised maps for each mode. The relevant maps and functions for petrol or natural gas operation are selected depending on the mode of operation.Natural gas has a knock resistance of 130 RON. RON (Research Octane Number) means: knock resistance determined in trials. This high resistance to knocking means that natural gas burns softer than petrol. The engine noise is pleasant and quieter.S262_044a18Technical data: Golf BI FUEL Engine code Capacity Engine type Valves per cylinder Bore Stroke Compression ratio Maximum output: Petrol Natural gas (H gas) Maximum torque: Petrol Natural gas (H gas) Engine management Fuel Exhaust gas treatment Emissions standard: Petrol Natural gas (H gas) BEH 2.0 l 4-cylinder in-line engine 2 82.5 mm 92.8 mm 10.5 : 1 85 kW at 5250 rpm 75 kW at 5500 rpm 175 Nm at 3250 rpm 151 Nm at 3750 rpm Motronic ME 7.1.1 (G) Petrol with 95 RON / natural gas Exhaust gas recirculation; catalytic converter EU IV EU III/D4Comparison between petrol and natural gas: Golf BI FUEL Output TorquePetrolPetrolOutput kWH gasH gasEngine speed (rpm)Engine speed (rpm)S262_042S262_043Torque Nm19Natural gas storageThe different methods of storing natural gas fuelNatural gas can be stored in two different ways: • CNG storage (Compressed Natural Gas) • LNG storage (Liquefied Natural Gas)CNG storage In order to make a sufficient quantity available for natural gas operation, the natural gas is compressed to a maximum of 200 bar with this method. Special pressurised gas containers are required for this type of storage. This is favoured by Volkswagen.LNG storage Since natural gas is always in a gaseous state, it is cooled down considerably with this method. The natural gas turns into a liquid at a temperature of minus 161 °C and can be stored in this state. For storage and transportation, special cooling tanks are required. This type of storage is used mainly for purposes of natural gas distribution.Space requirement and weight of different fuels In order to attain the same range with different types of fuel, the tank volumes must be different. The diagram below shows the required tank volume (blue) and the weight of the tank (yellow) for the different types of fuel.Steel tankCFRP tank (carbon fibre reinforced plastic)Petrol Diesel LPG Natural gasS262_085Weight in kilogramsTank volume in litresLNG should not be confused with LPG (Liquefied Petroleum Gas), also known as auto gas or fluid gas. LPG becomes liquefied at a pressure of 5 to 10 bar. It can be stored in a similar way to petrol at a pressure of 10 to 20 bar.20The natural gas tankAt Volkswagen, two different types of natural gas tanks are used for storage of CNG: • Steel tanks • CFRP natural gas tanks (carbon fibre reinforced plastic)Steel tanks In the Transporter ‘91 ➤ bivalent, two steel tanks of the same sort are used. These are sturdy and cheap but relatively heavy. A steel tank weighs approx. 80 kilograms and has a volume of approx. 80 litres. An 80 litre tank volume of natural gas equates to a weight of approx. 12.9 kilograms.Steel tanks in the Transporter ‘91 ➤ bivalentS262_05821Natural gas storageCFRP natural gas tanks (carbon fibre reinforced plastic tank) In the Golf BI FUEL, two different types of natural gas tanks made from carbon fibre reinforced plastic are installed. These two natural gas tanks have a total capacity of 74 litres and together they weigh 34 kilograms. A 74 litre tank volume of natural gas weighs 11.9 kilograms. The natural gas tanks of the Golf BI FUEL are installed in the luggage compartment. A separate cover protects the natural gas tanks from external influences and damage.Due to the large amount of space required for the gas tank, the Golf BI FUEL is only available as an estate.CFRP natural gas tank in the Golf BI FUELS262_048Extract from pressurised container regulations: The natural gas tanks should only be installed and covered to a degree that enables periodical inspections to be carried out without difficulty and without the need for tools.22The natural gas tank in the Golf BI FUELProtective capSteel tensioning strapsThermal safety deviceValve for tank shutoffS262_073Aluminium connecting flangePolyethylene base structure Carbon fibre reinforced epoxi-resin layersPolystryrol PolycarbonateThe natural gas tank of the Golf BI FUEL comprises of a polyethylene base structure, which is surrounded by several carbon fibre reinforced epoxi-resin layers. There are aluminium connecting flanges on both ends of the tank as a means of mounting the thermal safety device and the tank shutoff valve.To protect the ends of the natural gas tank there are protective caps. These protective caps comprise of a polycarbonate outer skin and a polystyrol inner layer. The natural gas tanks are attached in the vehicle by two steel tensioning straps.The thermal safety device is part of the natural gas tank and should not be removed.23Natural gas storageThe tank inspection intervalsThe natural gas tanks should only be filled if their period of certification is still valid. Once the period expires, filling is only permissible after an inspection has been carried out. For this reason, the natural gas tanks must be checked at regular intervals by an approved body (vehicle or technical inspectorate). Test certificates for natural gas tanks The pressurised container regulations require the natural gas tanks to be marked clearly.Transporter ‘91 ➤ bivalent Stamped test certificates on steel tanks •TÜ 12• 04/98 • 03 • 08Number and identification code of test station Month/year of first test Year of first periodical inspection Year of second periodical inspectionS262_050In this example, the inspections are carried out every five years. A new test certificate is stamped on the tank each time an inspection is carried out. Seal on gas filling connection • 12 • 04/2008 Number of testing station Month/year of periodical inspectionS262_036Year and month of inspectionAll periodical inspections must be carried out in the same month as the first inspection. The first inspection is carried out prior to initial filling by the manufacturer. For all periodical inspections thereafter, the vehicle owner/vehicle operator is responsible.24Golf BI FUEL Information on fuel tank flap On the inside of the fuel tank flap on the Golf BI FUEL there are warning notices. In addition to the normal data, the following natural gas relevant details can be found: • Quality of natural gas, medium (H/L gas) • Maximum fill pressure, 200 bar • Date next safety inspection of natural gas tank is due, example here shows month 05/year 2006Next month: 05S262_072Next year: 2006Natural gas tank information The natural gas tanks of the Golf BI FUEL feature data plates. All natural gas relevant details can be gleaned from the adjacent data plate. The natural gas relevant details are: • Date of first visual inspection, month 05 - year 2003 • Operating pressure at 15 °C, 20 MPa equates to 200 bar • Test pressure, 33 MPa equates to 330 bar • Operating temperature, –40 °C to +65 °C • Date of last use month 05 - year 2023 • Filling medium, natural gas (CNG)S262_086The legal requirements currently applicable in Germany are being revised by the Federal Ministry of Transport, Construction and Housing. Among other things, the revision is designed to determine the following two points: – Maximum period of use for natural gas tank: 20 years – Natural gas system to be inspected every 36 months for suitability by natural gas vehicle specialist The final version of the revised legal requirements was unavailable at the time of publication. 25Natural gas components in Golf BI FUELOverview of componentsThis component overview is based on the Golf BI FUEL system and shows all the parts required for gas operation.Filling connection with non-return valve and filterHigh pressure natural gas lineSensor for tank pressure (high pressure side)Gas pressure regulator with high pressure valve for gas operationLow pressure natural gas lineSensor for gas fuel rail (low pressure side) Gas fuel rail with gas inlet valves26Non-return valve (natural gas tank I only)Solder sealValve for tank shutoff Flow rate limiterNatural gas tankThermal safety deviceNatural gas tank I Natural gas tank IIOperating mode switchDash panel insertMotronic control unitS262_00127Natural gas supply in Golf BI FUELSystem overview of natural gas supplyFlow diagram of natural gas relevant components for high and low pressure sideGas pressure regulator with high pressure valve for gas operation High pressure natural gas line Filling connection with cap, non-return valve and filter and filter Sensor for tank pressure (high pressure side)Gas-tight sleeveFilterNon-return valveValve for tank shutoffSafety device Natural gas tankPressure relief valveHigh pressure side – Filling connection with cover cap, non-return valve and filter – Gas-tight sleeve for pressure line within vehicle – Natural gas tank – Non-return valve – Valve for tank shutoff with: • Electromagnetic shutoff valve • Mechanical shutoff valve • Solder seal • Flow rate limiter – – – – Thermal safety device High pressure natural gas line Sensor for tank pressure Gas pressure regulator with • High pressure valve for gas operation • Filter • Two pressure reduction stages • Pressure relief valve28The interface between the high and low pressure side is provided by the gas pressure regulator.Low pressure natural gas lineSensor for gas fuel rail (low pressure side) Pressure reduction stage 1 and 2Gas fuel railGas inlet valvesS262_028Low pressure side – Gas pressure regulator – Flexible low pressure natural gas line – Gas fuel rail – Sensor for gas fuel rail – Gas inlet valves29Natural gas supply in Golf BI FUELFlow chart of natural gas supply systemIn the flow chart below, all of the components of the natural gas system can be seen. On the following pages, the individual components of the natural gas system are described in detail.Flow chartThe flow chart shows the direction of flow and the parts as symbols. All components are shown in the rest state.Natural gas tank II 200 barSafety device 13 barNatural gas tank I9 bar18 bar Safety device Gas fuel rail with gas inlet valves N366 – N369S262_110Filling connection with non-return valveGas pressure regulator, 2 stageKey 1 - High pressure natural gas line 2 - Low pressure natural gas line N361 - Valve 1 for tank shutoff N362 - Valve 2 for tank shutoff N372 - High pressure valve for gas mode30The high pressure sideFilling connection, type NGV-1 (NGV - Natural Gas Vehicle) It can be found on the rear right of the vehicle. It is covered by a retractable cover. A particulate filter and a non-return valve are integrated in the filling connection. The filter is maintenance-free. It cleans itself when pressure is released in the tank supply line to the nozzle.S262_059High pressure natural gas line The high pressure natural gas line is made of stainless steel and is designed for pressures above 200 bar. It joins the filling connection with the tank and this in turn with the gas pressure regulator. It is routed firmly along the body.Double clamping ring connection “loose”S262_080aTo ensure good gas-tight properties, the individual elements are joined together with a double clamping ring connection. The high pressure natural gas line is routed on the underside parallel to the petrol line.Stainless steel pipeFront clamp ringRear Union nut clamp ring“tightened”S262_080bThe natural gas components installed on the inside of the vehicle must be equipped with a gastight sleeve.31Natural gas supply in Golf BI FUELValve 1 and 2 for tank shutoff N361 and N362 A tank shutoff valve is screwed into the right end of each natural gas tank. When facing the direction of normal travel, the tank shutoff valve 1 N361 is installed on the rear gas tank (natural gas tank I). Tank shutoff valve 2 N362 can be found on the front natural gas tank (natural gas tank II).S262_073aNatural gas tankValve for tank shutoffPurpose The tank shutoff valves regulate the supply of natural gas within the vehicle. With the components listed as follows, they each form a safety device: • • • • • Electromagnetic shutoff valve Solder seal Mechanical shutoff valve Non-return valve (natural gas tank I only) Flow rate limiterTank shutoff valve in removed stateElectromagnetic shutoff valve (solenoid)Flow rate limiterS262_089Solder seal Non-return valve Mechanical shutoff valveThe tank shutoff valves have a tapered thread and must therefore not be reinstalled once unscrewed. If a tank shutoff valve is loosened, it must be replaced with a new one.32Diagram showing flow of tank shutoff valves 1 and 2 The adjacent chart shows the direction of flow and all of the components of the tank shutoff valve as symbols. Both tank shutoff valves have the same design. 1 2 3 4 5 Mechanical shutoff valve Flow rate limiter Solder seal Electromagnetic shutoff valve Non-return valve (natural gas tank I only)To engineTo gas tankFrom filling connectionS262_090Mechanical shutoff valve The mechanical shutoff valve is highlighted in the adjacent diagram. The natural gas tank can be sealed gas-tight with an open-jaw spanner via the mechanical shutoff valve. For reasons of safety, the connection of the solder seal is not sealed even when the shutoff valve is closed.Mechanical shutoff valveS262_091If there is a smell of gas or repair measures are necessary, the mechanical shutoff valve must be closed.33Natural gas supply in Golf BI FUELFlow rate limiter The flow rate limiter (restriction in flow) is a safety valve and can be found on tank shutoff valve 1. It prevents accidental and rapid outlet of natural gas from the tank in the event of damage to the natural gas lines. The flow rate limiter is adjusted by the spring so that it closes at a pressure difference of 2 bar.Flow rate limiter “open” SpringFrom gas tankS262_071aSquare guide Ball sealSeal seatFunction If the natural gas line is torn away or starts leaking, the pressure in the natural gas line will drop within a short space of time by 2 bar. This sudden drop of pressure results in the pressure in the natural gas tank rising considerably above the pressure difference of 2 bar and pushes the ball seal into the seal seat via the square guide. The natural gas tank is thereby sealed and no more natural gas can escape.Flow rate limiter “closed” SpringFrom gas tankS262_071bSquare guide Ball sealSeal seatAfter repair work to a damaged natural gas line has been carried out, a closed flow rate limiter can be opened again by replenishing the natural gas system.34Solder seal The solder seal is also installed in the tank shutoff valve. It prevents the natural gas tank from bursting as a result of an excessive increase in pressure caused by fire. The solder seal is installed so that a direct discharge is possible at any time.From gas tankS262_096Solder sealFunction The melting point of the solder in the seal is approx. 110 °C. If the solder seal reaches a temperature of approx. 110 °C as a result of a fire, it will begin to melt. The solder seal is housed in the porous pressure chamber. The natural gas can escape from the natural gas tank via the discharge holes and flare off in a controlled manner.Discharge opening Pressure chamber Connection SolderS262_069Sealing pinThis thereby prevents the natural gas tank from bursting as a result of excessive pressure.During normal operation, the porous pressure chamber prevents the solder from draining away by the application of gas pressure.35Natural gas supply in Golf BI FUELElectromechanical shutoff valve The electromechanical shutoff valve is highlighted in the adjacent diagram. It consists of an electromagnetic valve with a solenoid and a mechanical valve. The electromagnetic valve is closed when not energised and completely seals the natural gas tank.Mechanical valveSolenoid Electromagnetic valveS262_092Function The electromagnetic shutoff valves open if the ignition is switched on (term. 15). To do this, the Motronic control unit J220 actuates relay 1 for shutoff valve J651. If the electromagnetic shutoff valves are open, the complete high pressure side is subjected to pressure. Effects of signal failure If the electromagnetic shutoff valves are not actuated or are defective, natural gas operation is not possible.Electrical circuit diagram(earth)S262_093If a crash signal is triggered, the electromagnetic shutoff valves are closed automatically.36Electromagnetic shutoff valve when tank is being filled The adjacent picture shows the direction of natural gas flow in colour during replenishment. When the vehicle is being replenished, the fuel is filled into the natural gas system of the Golf BI FUEL at a pressure of 200 bar. The mechanical valve in the electromagnetic shutoff valve is opened mechanically against spring pressure by the pressure of the natural gas during replenishment. The gas flows into the natural gas tank. Once a pressure of 200 bar is reached in the gas tank, the mechanical valve closes again under spring pressure.Mechanical valve To gas tankDirection of flow when fillingS262_094Electromagnetic shutoff valve opened electrically In order that natural gas can be made available to the engine for natural gas operation, the electromagnetic shutoff valve has to be actuated. Once the solenoid is energised, the electromagnetic valve opens and gas finds its way from the natural gas tank to the engine.To engine From gas tankSolenoidS262_09537Natural gas supply in Golf BI FUELNon-return valve The non-return valve prevents accidental back flow of natural gas in the lines and to the outside via the filling connection. Two non-return valves are installed in the Golf BI FUEL. One non-return valve can be found directly on the filling connection. The second non-return valve can be found on tank shutoff valve 1 (natural gas tank I).Seal seatSpringValve “open” During replenishment, the gas is filled from the pump at high pressure and this forces the ball seal off the seal seat against spring pressure. Gas finds its way into the tank.S262_061aBall sealSeal seatSpringValve “closed” If pressure is missing at the left of the ball seal when replenishment is complete, spring pressure and internal tank pressure push the ball seal back into the seal seat. Back-flow of the gas is thereby prevented.S262_061bBall sealTo reach the high demands on safety, guideline 757 of the VdTÜV (association of vehicle/ technical testing stations) prescribes the installation of two non-return valves between the filling connection and the natural gas tank.38Thermal safety device To increase safety in the event of a fire, there is an additional thermal safety device on the left end side of each natural gas tank in the Golf BI FUEL. This thermal safety device comprises of a housing into which a tube - a so-called cuvette is screwed. This tube is filled with a special fluid. After a certain time, the fluid expands at a predetermined temperature by a prescribed value.Safety deviceNatural gas tankS262_073bFunction In the event of a fire, the fluid in the cuvette expands so much from the build up of heat that the cuvette ejects at a temperature of 110 °C after approx. seven seconds. Once the cuvette ejects, the seal is opened. Gas can escape from the natural gas tank via the overflow channel, the ejected cuvette and the discharge openings. The natural gas can flare off into the open in a controlled manner. This thereby prevents the natural gas tank from bursting.Overflow channelDischarge openingHousing Seal CuvetteS262_068The thermal safety device should not be loosened. It is part of the natural gas tank and can only be renewed by the manufacturer of the natural gas tank.39Natural gas supply in Golf BI FUELGas pressure regulator The gas pressure regulator of the Golf BI FUEL is housed on the front right longitudinal member in the wheel housing. It features a plastic cover as a means of protection against water splashes and stone chips.Gas pressure regulatorPurpose The gas pressure regulator reduces natural gas pressure in two stages from a maximum 200 bar to approx. 9 bar. It thereby separates the high pressure side from the low pressure side.Shown without plastic cover around gas pressure regulatorS262_064Design The gas pressure regulator is another form of safety device and features the components listed as follows: • • • • • • • Engine coolant connections Filter Sensor for tank pressure, G400 1st pressure reduction stage 2nd pressure reduction stage High pressure valve for gas mode, N372 Pressure relief valveConnection high pressure sideSensor for tank pressureHigh pressure valve for gas operationEngine coolant connectionConnection low pressure side Filter Pressure relief valveS262_007Up to the gas pressure regulator in the natural gas tank there could be a maximum pressure of 200 bar.40Engine coolant connections The gas pressure regulator reduces pressure on the high pressure side from a maximum 200 bar to approx. 9 bar on the low pressure side. This reduction in pressure occurs by means of expansion of the natural gas. The results in a rapid drop in temperature that could ice up the gas pressure regulator. Purpose The gas pressure regulator is connected to the small coolant circuit via the engine coolant connections. By means of these connections, the temperature of the gas pressure regulator is maintained at engine operating temperature, i. e. approx. 100 °C. Icing up is thereby prevented.Engine coolant connectionsS262_112Filter Installed in the gas pressure regulator is a maintenance-free filter on the high pressure side. This serves as a means of filtering out any contaminants in the natural gas to prevent damage occurring to the sensitive components on the low pressure side.FilterS262_11141Natural gas supply in Golf BI FUELSensor for tank pressure G400 The sensor for tank pressure is fitted to the gas pressure regulator. Purpose The sensor for tank pressure calculates the gas pressure on the high pressure side directly before the first pressure reduction stage. The Motronic control unit requires the signal from the tank pressure sensor in order to actuate the natural gas fuel gauge G411 in the dash panel insert. The signal is still needed in order to change over to natural gas operation.S262_064aPressure regulatorDesign The tank pressure sensor comprises of: • Housing with pressure connection • Sensor element (steel membrane and expansion test strip) • Electronics system • Electrical connectionTank pressure sensorElectrical connection Electronics systemEffects of signal failure If there is no signal from the tank pressure sensor at the Motronic control unit or if the sensor is defective, gas operation is not possible.Expansion test strip Steel membraneHousing with press. connectionS262_09742Function Gas pressure on the high pressure side makes its way to the sensor element via the pressure connection on the tank pressure sensor. The sensor element comprises of a steel membrane, on which the expansion test strip is located. A change in pressure alters the bending radius of the steel membrane and thereby also the expansion test strip. This results in a change in the resistance value of the expansion test strip. As pressure rises, the resistance value drops and voltage increases. The electronics system is supplied with 5 volts of power. The electronics system calculates a voltage signal from the current resistance value and transmits this to the Motronic control unit.Voltage pressure chartVoltage signal [V]S262_098Gas pressure [bar]At a pressure of below 13 bar, the Motronic control unit switches automatically to petrol mode.43Natural gas supply in Golf BI FUELFrom high pressure to low pressureThe pressure of the natural gas on the low pressure side must be approx. 9 bar. In order to maintain a pressure of 9 bar as constant as possible, the natural gas pressure must be reduced from a maximum 200 bar in two stages. This drop in pressure occurs in the two reduction stages in the gas pressure regulator. To do this, the high pressure valve for gas mode N372 must be open.1st pressure reduction stage In the 1st pressure reduction stage, the gas expands (arrow) against stage 1 spring pressure. Gas pressure is reduced from a maximum 200 bar to 13 bar. The gas, now reduced in pressure, makes its way to the 2nd pressure reduction stage via the overflow channel.Connection High pressure side1. Pressure reduction stageFilterPressure stage 1Spring pressure stage 1S262_049aOverflow channelPressure relief valve (closed)Tank pressure up to maximum 200 bar 1. Pressure reduction stage to 13 bar 2. Pressure reduction stage to 9 bar44High pressure valve for gas mode N372 (open) Electrical connection2nd pressure reduction stageSpring pressure stage 2In the 2nd pressure reduction stage, the gas expands (arrow) against stage 2 spring pressure. At the connection on the low pressure side, the natural gas is reduced from 13 bar to approx. 9 bar and is made available to the gas fuel rail. The pressure in the gas fuel rail can be between 8.0 and 9.5 bar.Connection low pressure sidePressure stage 22nd pressure reduction stageS262_049 S262_049cOverflow channel45Natural gas supply in Golf BI FUELHigh pressure valve for gas mode N372 The high pressure valve for gas mode is an electromagnetic shutoff valve. It is installed directly on the gas pressure regulator and comprises of a solenoid and a valve. The high pressure valve for gas mode is closed when not energised and controls the supply of gas to the engine.Function When ignition is switched on (term. 15), the Motronic control unit (J220) actuates the high pressure valve (N372) via relay 1 of the shutoff valve (J651) to facilitate opening. Effects of signal failure If the high pressure valve for gas mode is not actuated or is defective, natural gas operation is not possible.Electrical circuit diagramS262_114(earth)High pressure valve “closed”Tank pressure ready (maximum 200 bar)SolenoidS262_078aFilter High pressure valve “closed” Engine coolant circuit connectionsS262_078The valve is closed automatically when a crash signal is triggered.46The low pressure sidePressure relief valve The pressure relief valve is integrated in the 1st pressure reduction stage and increases safety in the gas system. It operates purely mechanically by means of the pressure relief valve spring. The pressure relief valve spring is set to a pressure of 18 bar. At a pressure of 18 bar in the 1st pressure reduction stage, the spring washer of the pressure relief valve is pushed back against spring pressure. The pressure relief valve opens and natural gas escapes to the open. In this way, damage to the gas pressure regulator and to the low pressure side is avoided.1st press. reduction stageGas escapes to the openS262_079S262_079aSpring of pressure relief valvePressure relief valve “open”Tank pressure up to maximum 200 bar 1. Pressure reduction stage 18 bar47Natural gas supply in Golf BI FUELLow pressure natural gas line The low pressure side starts directly after the 2nd pressure reduction stage in the gas pressure regulator. Natural gas pressure is approx. 9 bar. Due to the low pressure, a flexible low pressure gas line (steel flex line) is installed from the gas pressure regulator to the gas fuel rail. The movement of the engine brought about by load changes is compensated for by the flexible low pressure natural gas line.S262_009Gas inlet valvesGas fuel rail The gas fuel rail is also installed on the intake manifold of the engine. The four gas inlet valves N366 to N369 and a gas fuel rail sensor G401 are installed on the gas fuel rail. Similar to the common rail system on a diesel engine, the gas is distributed to the inlet valves via a “gas fuel rail” or “gas rail”.S262_010Gas fuel railSensor for gas fuel rail48Gas inlet valves N366 to N369 The natural gas enters the inlet port sequentially and selectively of the respective cylinder via an electronically controlled gas inlet valve at a pressure of approx. 9 bar. The design and function of the gas inlet valve is essentially the same as an electromagnetic petrol injector valve. There is an electrical connection and a magnetic coil in the valve housing. The valve group is formed by the valve body and the valve needle that passes through it with solenoid armature attached. The valve is closed when the magnetic coil is not energised. The coil spring and gas pressure on the low pressure side push the valve needle in the seat of the valve outlet seal. When the magnetic coil is energised, a magnetic field is generated. The solenoid armature is thereby pulled up and this lifts the valve needle off its seat. The injector is opened. Natural gas makes its way into the combustion chamber via the inlet port.Gas inlet valve Gas fuel rail connection Magnetic coil Coil spring InjectorSeal seatS262_076Electrical connectionSolenoid armature with valve needle49Natural gas supply in Golf BI FUELSensor for gas fuel rail G401 The gas fuel rail sensor is screwed into the righthand side on the end of the gas fuel rail.Gas fuel railPurpose The gas fuel rail sensor determines the current gas pressure in the gas fuel rail. The Motronic control unit requires the signal from the gas fuel rail sensor in order to determine the period of gas inlet at the valves and also to make any necessary adjustments.S262_062SensorDesign The gas fuel rail sensor comprises of: • Housing with pressure connection • Sensor element (steel membrane and expansion test strip) • Electronics system • Electrical connectionElectrical connection Electronics systemExpansion test strip Steel membraneHousing with press. connectionS262_099The basic design and function of the gas fuel rail sensor G401 is identical with that of the tank pressure sensor G400.50Function The sensor element is supplied with +5 volts of power and comprises of a steel membrane to which expansion test strips are attached. The resistance value of the expansion test strips drops as gas pressure rises. The resistance value is picked up by the electronics system and is sent to the Motronic control unit as a voltage figure.Effects of signal failure If the gas fuel rail sensor is defective or if the voltage figure is not between 3.0 volts and 4.5 volts, the Motronic control unit switches automatically to petrol mode.Voltage pressure chartVoltage signal [V]S262_113Gas pressure [bar]51Natural gas supply in Golf BI FUELThe technical safety conceptIn order to assure a high level of operating safety on natural gas powered vehicles, the natural gas is given an additive (odorised). In this way, even the slightest of leaks in the natural gas system can be detected by sense of smell. The natural gas system of the Golf BI FUEL was developed with emphasis on crash safety and operating safety. Therefore, the Golf BI FUEL fulfils the technical safety demands, for example, currently valid for a tail end crash. Operating safety of the Golf BI FUEL is assured by the components listed as follows and their functions. 7 An electromechanical shutoff valve (1 per tank) closes: on changeover to petrol mode, in the event of power failure, engine stop or a crash. 8 A flow rate limiter (1 per tank) prevents sudden dumping of the tank in the event of pipe breakage.1 2 1 Non-return valves in the filling connection and on the tank shutoff valve (natural gas tank I) prevent back-flow of gas via the tank valve. 2 A gas-tight sleeve surrounds the gas lines routed within the vehicle. The sleeve breaths downwards to the outside. 3 The gas lines are made from stainless steel. 4 All threaded connections feature double clamping ring connections. 5 One solder seal and … 6 one thermal safety device per tank prevent excessive pressure increase in the event of a fire and thereby bursting of the tank. 1 34 5 7 8 9 6Work on the high pressure side of the natural gas system should only be carried out by trained specialists with special certificate of trade proficiency.529 The natural gas tanks must be inspected regularly by a GSG specialist (Gerätesicherheitsgesetz - German equipment safety regulations) in line with regulations concerning pressurised containers. 10 An electromechanical shutoff valve on the pressure regulator closes: on changeover to petrol mode, in the event of power failure, engine stop or a crash.11 A flexible gas line on the low pressure side prevents cracks from vibrations. 12 The gas inlet valves only open when they have been actuated by the engine control unit. 13 A pressure relief valve on the gas pressure regulator protects the low pressure side.101112 13S262_02853Engine managementThe system overview of sensors and actuatorsSensor for tank pressure G400Sensor for gas fuel rail G401Operating mode switch E382Engine speed sender G28Hall sender G40Air mass meter G70 Intake air temperature sender G42Coolant temperature sender G62Lambda probe G39 Lambda probe after catalytic converter G130Diagnosis connectionAccelerator pedal position sender G79 Accelerator pedal position sender 2 G18554Motronic control unit J220Valve 1 and 2 for tank shutoff N361 and N362High pressure valve for gas mode N372CAN power train data busRelay 1 for shutoff valve J651Dash panel insertGas inlet valves 1 to 4 N366 to N369Fuel pump shutoff relay J333Natural gas fuel gauge G411Natural gas mode control lamp K192S262_06055Engine managementThe system functionsOperating mode switch E382 The operating mode switch can be used to change between natural gas and petrol operation. If the operating conditions as follows are fulfilled, the Motronic control unit J220 switches over to natural gas operation: • Operating mode switch in position “GAS” • Natural gas pressure on high pressure side greater than 13 bar • Engine speed greater than 2000 rpm • Engine in overrun • Coolant temperature greater than 20 °CElectrical circuit diagram The operating mode switch is supplied with power from terminal 15. The double contact is closed in the “GAS” position. Control lamp 2 for natural gas operation K235 lights up. The control lamp shows only the driver intention and not whether gas operation is actually active. The switch illumination bulb L156 is supplied with power from the switches and instruments illumination regulator E20. Effects of signal failure If the operating mode switch is defective, or if the Motronic control unit receives no signal, natural gas operation is not possible.(earth)S262_024S262_10156Dash panel insert Housed in the dash panel insert are the displays for natural gas operation: • Natural gas mode control lamp K192 • Natural gas fuel gauge G411 The control lamp for natural gas mode K192 has two functions: 1. It only lights up in active gas mode. 2. It flashes if active gas mode is not possible.The natural gas fuel gauge G411 has eight display segments that light up depending on the fill pressure of the gas tank. If the gas tank is more than 90 % filled, all eight segments will light up. No segments are lit below 10 %. The natural gas fuel gauge is always active when ignition is switched on.Natural gas mode control lamp K192 Natural gas fuel gauge G411S262_023Electrical circuit diagram The Motronic control unit J220 sends information for actuation of the • natural gas mode control lamp K192 and • natural gas fuel gauge G411 via the CAN power train data bus to the databus diagnosis inferface J533 in the dash panel insert.CAN power train data busS262_10257Engine managementRelay 1 for shutoff valve J651 Relay -1- for the shutoff valve is installed on the additional relay carrier above the relay board. Actuation The relay is actuated by the Motronic control unit J220 when ignition (term. 15) is switched on.(earth)S262_103Function If relay -1- for the shutoff valve is actuated, the relay passes voltage from terminal 15 via a fuse to the tank shutoff valves N361/N362 and to the high pressure valve for gas mode N372. In this operating condition, the prerequisites for natural gas operation are fulfilled. All natural gas components are made ready for gas operation. The Motronic control unit has not yet switched over to active natural gas operation.If a crash signal is triggered, relay -1- for the shutoff valve is no longer actuated by the engine control unit.58Fuel pump shutoff relay J333 The fuel pump shutoff relay is installed on the additional relay carrier above the relay board. Actuation The relay is actuated by the Motronic control unit J220 if changeover to natural gas operation is selected. To changeover to active natural gas operation, the following conditions have to be met. • Ignition (term. 15) switched on • Natural gas pressure on high pressure side greater than 13 bar • Operating mode switch in position “GAS” • Engine in overrun • Engine speed greater than 2000 rpm • Coolant temperature greater than 20 °C(earth)S262_104Function If the fuel pump shutoff relay is actuated, the relay interrupts power supply between the fuel pump relay J17 and the fuel pump G6. In this operating condition, all prerequisites for active natural gas operation are fulfilled. The Motronic control unit has switched over to active natural gas operation. The engine is being run on natural gas.If a crash signal is triggered, the fuel pump relays J17 and J333 are no longer actuated by the Motronic control unit.59Engine managementEngine startThe engine is always started in petrol mode. In this way, the gas pressure regulator is warmed with engine coolant and there is no danger of it icing up. Changing over into gas mode can take up to 60 seconds after a cold start. Changing over to active natural gas operation The Motronic control unit J220 switches over to active gas mode once the following prerequisites have been fulfilled:• Ignition (term. 15) switched on (relay 1 for shutoff valve J651 is actuated by the Motronic control unit J220) • Operating mode changeover switch in position “GAS” • Sensor for tank pressure G400 Natural gas pressure greater than 13 bar• Coolant temperature sender G62 Engine coolant temperature greater than 20 °C • Engine speed sender G28 Engine speed greater than 2000 rpm • Accelerator pedal position sender G79 Load detection, subsequently idling speed detection (overrun)Once these conditions have been met, the Motronic control unit actuates the fuel pump shutoff relay J333. At the same time, the gas inlet valves N366 to N369 are actuated. Changing back into petrol mode is possible at any time.Function cycle“ON”S262_105If the engine cannot be started in petrol mode due to an empty fuel tank, an emergency start can be carried out. The emergency start can be carried out up to five times in natural gas mode. An engine start in gas mode is not possible thereafter.60Motronic control unit J220 The Motronic control unit is installed in the plenum chamber. Stored in the Motronic control unit is a separate map for both petrol operation and natural gas operation. By the application of two maps, it was possible to adapt the control unit to the respective requirements of the different types of fuel, as appropriate. If natural gas mode is not possible, the Motronic control unit switches to petrol mode automatically.S262_022Lambda control For complete combustion, a petrol engine requires, in theory, a mixture of 14.7 kg of air and 1 kg of fuel (petrol). In the case of complete combustion, the air figure is λ (lambda) = 1. In natural gas mode λ = 1 with an air to natural gas ratio of 5.41 : 1 [kg]. Function The lambda probe monitors the mixture composition in natural gas mode as well. If the value measured by the lambda probe exceeds λ = 1, the mixture is too lean. The Motronic control unit extends the inlet period and thereby enrichens the mixture. Effects of signal failure In the event of failure or a defective lambda probe, natural gas operation continues in emergency running mode.S262_106Lambda 1Lambda 161Engine managementThe function chart, Transporter ‘91 ➤ bivalentE382 - Operating mode changeover switch for petrol/ gas mode F60 - Idling switch G28 - Engine speed sender G39 - Lambda probe G40 - Hall sender G62 - Coolant temperature sender G69 - Throttle valve potentiometer G71 - Intake manifold pressure sender G88 - Throttle valve positioner potentiometerG400 G401 G411 G412 J16 J338 J361 J651 J653 J664-Tank pressure sensor Gas fuel rail sensor Gas fuel gauge Coolant temperature sender of natural gas Power supply relay Throttle valve module Simos control unit Relay 1 for shutoff valve Bivalent operation control unit 1 Relay box for gas mode62S262_053K192 N30 … N33 N83 N364 N366 … N370 V60 Z19 -Natural gas mode control lamp Injectors for cylinders 1 to 4 Injector for cylinder 5 Gas pressure regulator shutoff valve Gas inlet valves for cylinders 1 to 5 Throttle valve positioner Lambda probe heatingNatural gas relevant components are shown in bolder colours in the chart.= Positive = Earth63Engine managementThe function chart, Golf BI FUELCAN power train data busA D/term.15 E20 E382 G6 G186 G187 G188 G400 G401 G411 J17 J220 J234-Battery Ignition switch/ignition ON Switches and instruments illumination regulator Operating mode changeover switch for petrol/ gas mode Fuel pump Throttle valve drive for electric throttle Throttle valve drive angle sender 1 for electric throttle Throttle valve drive angle sender 2 for electric throttle Tank pressure sensor Gas fuel rail sensor Gas fuel gauge Fuel pump relay Motronic control unit Airbag control unitJ333 J338 J533 J651 K192 K235 L156 N30 … N33 N156 N261 N361 N362 N366 … N369 N372 TK -Fuel pump shutoff relay Throttle valve module Data bus diagnosis interface Relay 1 for shutoff valve Natural gas mode control lamp Natural gas mode control lamp 2 Switch illumination bulb Injectors for cylinders 1 to 4 Variable intake manifold changeover valve Variable intake manifold changeover valve 2 Tank shutoff valve 1 Tank shutoff valve 2 Gas inlet valves 1 to 4 High pressure valve for gas mode Door contact64S262_032E45 F F36 F47 G28 G39 G40 G61 G62 G66 G70 G79 G130 G185 J271 J299 CCS switch Brake light switch Clutch pedal switch Brake pedal switch Engine speed sender Lambda probe Hall sender Knock sensor 1 Coolant temperature sender Knock sensor 2 Air mass meter Accelerator pedal position sender Lambda probe after catalytic converter Accelerator pedal position sender 2 Motronic power supply relay Relay for secondary air pump Term.31 N70 N79 N80 N127 N291 N292 P Q V101 Earth Ignition coil 1 with final output stage Heater element for crankcase breather Activated charcoal filter system solenoid valve 1 Ignition coil 2 with final output stage Ignition coil 3 with final output stage Ignition coil 4 with final output stage Spark plug connector Spark plug Motor for secondary air pumpNatural gas relevant components have bolder colours in the chart. = Positive = Earth65ServiceThe legal requirements in GermanyIn Germany, the following requirements must be fulfilled: Certificate of trade proficiency All service, maintenance and repair work on the high pressure side of the natural gas system should only be carried out by trained personnel with a special certificate of trade proficiency.To achieve a sufficient standard of trade proficiency, a course of training must be completed that meets guideline 757 of the VdTÜV (association of technical and vehicle testing stations).This training is offered by Volkswagen via the relevant sales centres as a training package “Specialist training for natural gas powered vehicles”.Note on lock carrierWarning! natural gas vehicle!be The natural gas system should only nnel. serviced by correctly trained persoS262_082Legal demands