TECHNICAL DOCUMENTATION
SSP 295 Diagnosis with VAS 5051, VAS 5052 and VAS 5053

This PDF is currently unavailable.
Read document text
Service TrainingSelf-study Programme 295Diagnosis with VAS 5051, VAS 5052 and VAS 5053Procedures and FunctionThere are constantly new innovations in vehicles. Simple tools are not suitable for diagnosis on these vehicles, therefore increasingly complex diagnosis systems are required. Diagnosis in Volkswagen and Audi vehicles was originally performed with the V.A.G 1550 tester and has been further developed with the V.A.G 1551 and V.A.G 1552 testers.However, today’s vehicles have electronic equipment that requires extensive diagnosis functions. This self-study program should help you use the VAS 5051 vehicle diagnosis, measuring and information system, the VAS 5052 vehicle diagnosis and service information system and the VAS 5053 vehicle diagnosis system properly in the service core process and the diagnosis process.S295_001This self-study program looks at innovations in diagnosis systems. Please refer to the operating manuals for the latest information on use of these diagnosis systems. The screenshots are examples and may differ from the screen content of the diagnosis systems. The number of screenshots has been reduced to the essential for reasons of clarity.NEWImportant NoteThe self-study programme shows the design and function of new developments. The contents will not be updated.For current testing, adjustment and repair instructions, refer to the relevant service literature.2ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Diagnosis Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Vehicle Self-diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Measuring Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Guided Fault Finding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Guided Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78Time Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Online Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Remote Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Emissions Testing Station . . . . . . . . . . . . . . . . . . . . . . . . . . 90Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Test Yourself . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 983IntroductionCore Service Activities in Networked DealershipsThe intermeshing of core service activities and all networking components ensures trouble-free procedures.Appointment preparation Thanks to the current expansion of the Volkswagen Audi workshop system VAWS to the second module in the service core process, staff handling appointments will be able to prepare orders in full. An order can then be opened quickly when the vehicle is received without the help of the service assistant.qMaking appointments When appointments are made, all customer, vehicle and replacement vehicle data should be entered. The order data is then assigned manually and automatically to the respective work areas and required diagnosis and measuring equipment. Staff qualifications are also taken into consideration.q q qqRecognised work items from the ELSA are listed Prices are imported from PASS Packages are automatically set in order Required parts are automatically checked for availability in the parts warehouse and any orders are made Any further additions to the order are enteredReceipt of vehicle The service assistant receiving/ handing over the vehicle has all relevant data on his PC screen. If unexpected problems or questions arise, the service assistant can forward all new information and data straight to the workshop, to the spare parts department and to the dealership organisation. Querying the fault memory with the VAS 5052 and VAS 5053 allows the necessary repair work to be assessed in case of a complaint.Creating an order The customer order is created on a blank order sheet in the DMS and is forwarded to ELSA. ELSA ensures display and selection of the order and forwards it to the asanetwork. From there, the tasks are forwarded to the workshop equipment. After the order has been processed, feedback is sent to ELSA and DMS. This rules out the risk of losing information.4Post-processing During post-processing by the call centre, you can access the system-supported appointment management again. All questions are sorted out with the customer, his remarks can easily be recorded. The customer and vehicle data can be recorded completely from the first to the last customer contact.Return of the vehicle/bill The return of the vehicle/billing also benefits from the networking as all order data is transferred back to VAUDIS. Diagnosis and repair protocols, displays and the order text are available to the service assistant. All customer questions can be answered directly and clearly. The bill is itemised and clear.Creating repair and service orders The precise preliminary work allows fast and reliable completion of the order. At the beginning of the order, the mechanic is informed which special tools and which spare parts are required. The observation of all agreements and order points ensure customer satisfaction. The VAS tester is used to carry out the repair, for example, the “Guided Fault Finding”, the service work and the “Guided Functions”.Quality control / preparation of the vehicle return It follows on immediately from the repair and service creation. In the networked dealership, the repair procedure can be referred to after the final check. In future, it will be possible for the service assistant to check the order status on the progress monitor.S295_0025IntroductionThe Diagnosis, Testing and Information System VAS 5051, the Diagnosis and Service Information System VAS 5052 and the Diagnosis System VAS 5053 in the service core processCreating repair and service orders A large part of the repair work involves diagnosing faults. The diagnosis is supported by the ELSA as well as the systems VAS 5051, VAS 5052 and VAS 5053. They can be used in all networked workstations and provide direct access to the latest literature (e.g. HST/TPL) as well as support from the manufacturer (e.g. SVM/Telediagnosis).Networking overviewEmissions testing control unitData flow in the workshopqqqqDuring diagnosis, all customer and vehicle data is forwarded to the connected equipment e.g. VAS 5051, VAS 5052, V.A.G 1813 and can automatically be called up at any workstation. During a repair, technical problem solutions can be checked or additional information can be called up on a daily basis on the VW ServiceNet® or Audi-ServiceNet®. Connecting to the network allows functions like: - Software updates for control units - Secret and component protection (GeKo) - Software version management (SVM) - Transferring diagnosis protocols - Telediagnosis - Software-supported procedures - and many other future functions The ELSA electronic service information system is available with the latest data.*6Data exchange between the sales areas and the workshopqqVAS 5051B VAS 5052 VAS 5053qqData on the workshop capacity for making/ preparing the appointment Data on the making/preparing the appointment and creating the order in the workshop area: customer, vehicle and appointment data Feedback on the latest repair data from the workshop via the progress monitor: The service assistant is informed about the repair progress and can intervene in the current process if necessary. Data return from the workshop to the dialog transfer for the quality control and the invoicing: The data on necessary work time and work positions as well as the spare parts required are is made available.Data flow between the workshop and the spare parts serviceq**S295_003The spare parts service is integrated in the service process from appointment preparation: In the service support process, the spare parts competence centres ensure that the parts flow is trouble-free in both directions.* Progress monitor ** System-supported appointment management7Diagnosis SystemsThe Vehicle Diagnosis, Testing and Information System VAS 5051EquipmentCable hanger VAS 5051/39ADiagnosis cablesDiagnosis unit VAS 5051Okipage 14ex printer VAS 5051/47 220V VAS 5051/48 110VS295_004Test equipment trolley VAS 5051/10Please refer to the latest equipment catalogue for the exact content.8VAS 5051 The Diagnosis, Testing and Information System VAS 5051 is a PC-based test unit and has the following modes:q q q q q q qVehicle self-diagnosis OBD (on-board diagnosis) Test Instruments Guided fault finding Guided functions Administration ApplicationsVAS 5051Diagnosis, Testing and Information System Version -GB- / V07.00.0018/06/2004 Vehicle self-diagnosis OBD Test Instruments Guided Fault Finding Guided FunctionsApplications PrintAdministrationVAS 5051S295_0069Diagnosis SystemsThe Vehicle Diagnosis, Testing and Information System VAS 5051BNew diagnosis unit Follow-up unit for VAS 5051 with additional functions and higher speedEquipmentDiagnosis unit VAS 5051BTest equipment trolley VAS 5051/9S295_007Please refer to the latest equipment catalogue for the exact content.10VAS 5051B The VAS 5051B vehicle diagnosis, testing and information system has the following modes:q q q q q q q qPropertiesq q qVehicle self-diagnosis OBD (on-board diagnosis) Test Instruments Guided fault finding Guided functions Administration Applications Elsa Win (not included)qCompatibility with existing units Use of existing trolleys and measuring leads Full network capability Same operating system as previous unitsVAS 5051Diagnosis, Testing and Information System Version -GB- / V07.00.0018/06/2004Elsa Win Vehicle self-diagnosis OBD Test Instruments Guided fault finding Guided functionsApplicationsAdministrationPrintS295_008New technical features in the VAS 5051B Vehicle Diagnosis, Testing and Information Systemq q q q15” display “Elsa Win” compatible Modern processor performance Expansion options via standard interfaces, e.g. USB printerq qBattery operation approx. 3 hours DSO measurement with a sampling rate of 40MHz with single-channel measurement 20MHz for two-channel measurement11Diagnosis SystemsVehicle Diagnosis and Service Information System VAS 5052EquipmentCarrying caseMains lead for base stationVAS 5052Base station with integrated power supplyTouchscreen penS295_009Headset VAS 5052/8Diagnosis lead VAS 5052/3Test adapter VAS5052/4Please refer to the latest equipment catalogue for the exact content.12VAS 5052 The VAS 5051B vehicle diagnosis and service information system has the following modes:q q q q q q qDescription The VAS 5052 has been updated using the basic CD V06.00.00. If necessary, the data for the operating modes “Guided Fault Finding” and “Guided Functions” can be installed. The measuring information is recorded using external units and subsequent manual input. The guided fault finding can thus be used above all for mobile diagnosis and test drives.Vehicle self-diagnosis OBD (on-board diagnosis) Guided fault finding Guided functions Elsa Win Administration ApplicationsVAS 5052Vehicle diagnosis and service information system Version -GB- / V07.00.00 18/06/2004Elsa Win Vehicle Self-diagnosis OBDGuided Fault Finding Guided FunctionsApplicationsAdministrationPrintS295_010All new information and the complete functions are only available when the unit is used on the dealership network.13Diagnosis SystemsVAS 5053 Vehicle Diagnosis SystemNew diagnosis unit Compact for vehicle receipt, vehicle service and mobile use.EquipmentBase station for VAS 5053Power supply for VAS 5053 VAS 5053S295_011Diagnosis lead for VAS 5053Please refer to the latest equipment catalogue for the exact content.14VAS 5053 The VAS 5053 vehicle diagnosis system has the modes:q q q q qVehicle self-diagnosis OBD Guided functions Administration ApplicationsVAS 5053 Vehicle Diagnosis System Version -GB- 07.00.0018/06/2004Vehicle self-diagnosis OBDGuided functionsApplicationsAdministrationPrintS295_012Technical data for vehicle diagnosis system VAS 5053q q q q6.5” TFT colour display “Elsa Win” compatible Modern processor performance Interfaces on tester: 1 x USB, 1 x LAN, PC-CARD, Compact UpdateqqInterfaces on the base station: 2 x USB 1 x LAN Power supply connection Battery operation approx. 3 hoursSoftware installation The installation or update of the software is performed using the VAS 5051B, VAS 5052 or a standard PC together with the included USB cable.VAS 5051B VAS 5053VAS 5052S295_13715Diagnosis SystemsAccessories for communication with the vehicle systemsVarious diagnosis leads are required to communicate with the systems (control units) installed in the vehicle.Diagnosis leads VAS 5051/5A and 6A The diagnosis leads VAS 5051/5A and 6A for the VAS 5051 allow diagnosis via diagnosis CAN (Controller Area Network) and the US standard J1850. They replace the previous diagnosis leads VAS 5051/1 (EU) and VAS 5051/5 (USA). Connector colour: Lead length: grey 3 m (5A) and 5 m (6A)S295_013Only the diagnosis leads VAS 5051/5A and 6A are suitable for diagnosis on vehicles with Diagnosis Controller Area Network. When the diagnosis lead VAS 5051/5A is used, the voltage for the VAS 5051 is supplied via the diagnosis connector in the vehicle (vehicle battery) if it is not connected to the 230V mains.Diagnosis lead VAS 5052/3 The diagnosis lead VAS 5052/5A for the VAS 5052 allows diagnosis via diagnosis CAN (Controller Area Network) and the US standard J1850. If the VAS 5052 not connected to the base station, the voltage supply via the diagnosis connection in the vehicle (vehicle battery). Connector colour: Length: blue 5mS295_01416K-lead adapter VAS 6017B The new K-lead adapter VAS 6017B is required for the Audi A4 2001 , Audi A4 2005 and the Audi A6 July 2001 to exchange data with all control units that are connected to the diagnosis connector T16 via various K-leads or CAN data bus lines. It should be plugged in before the respective diagnosis line. It is reverse compatible and replaces the previous K-lead adapter VAS 6017A. The yellow LED illuminates while the control unit is addressed.S295_015As soon as the control unit responds, the yellow LED and the corresponding green LED (K1 and K2) illuminates. (See also SSP 254 Audi A4 ‘01 - Technology)Test adapter VAS 5052/4 The test adapter is used to check the VAS 5052/3 diagnosis lead and the tester interface. When the self-test is carried out, the test adapter VAS 5052/4 needs to be connected to the VAS 5052/3 diagnosis lead to test the VAS 5052/3 diagnosis lead. The self-test is required if no diagnosis communication is possible. It is called up via the “Administration” menu item on the VAS 5052 and asks you to connect the test adapter during the program procedure. The further procedure appears as a mask on the screen.S295_01617Diagnosis SystemsThe Software StructureThe software required for the diagnosis systems is split between two CDs. Basic CDs The basic CDs contain the operating system and the procedure software as well as the software for the operating modes:q q q q q q qSelf-Diagnosis OBD Test Instruments Administration Applications Guided Fault Finding (only procedure) Guided Functions (only procedure)Basic CD VAS 5051The basic CDs cover all brands and provide a platform for all brands. They are required to run the brand CDs and need to be installed first.Basic CD VAS 5052Once the basic CD has been installed, the number of the software version before the point is changed. A compatible brand CD has to be installed next so that the “Guided Fault Finding” and “Guided Functions” modes are available again.Basic CD VAS 5053 Standard laptop for transferring the update to VAS 5053The basic CDs for the diagnosis systems VAS 5051, VAS 5052 and VAS 5053 are different and only work with the respective diagnosis systems they are intended for. Incorrect use can lead to the equipment not functioning.Workshop server18Brand CDs The brand CDs include the data for the modes:q qGuided fault finding Guided functions They are brand-specific and cannot run without a basic CD.Audi brand CD VAS 5051Seat brand CDVAS 5051B Skoda brand CDVAS 5052 Volkswagen brand CD Brand-specific update CDs VAS 5053S295_017Since 1 July 2004, it has been possible in Germany to download updates of brandspecific functions and new versions. There are therefore no more brand and update CDs.Online update: Basic data Brand data Update data19Operating modesOverviewThe diagnosis functions of the VAS diagnosis units are subdivided into individual modes. Operation in the individual modes is identical with all systems. VAS 5051 modesq q q q q q qVAS 5051B modesq q q q q q q qVehicle Self-Diagnosis OBD (on-board diagnosis) Test Instruments Guided Fault Finding Guided Functions Administration ApplicationsVehicle Self-Diagnosis OBD (on-board diagnosis) Test Instruments Guided Fault Finding Guided Functions Administration Applications ELSA Win (not included)VAS 5051 Vehicle Diagnosis, Testing and Information System Version -GB- / V07.00.0018/06/2004Vehicle Self-Diagnosis OBD Test Instruments Guided Fault Finding Guided FunctionsVAS 5051B Vehicle Diagnosis, Testing and Information System Version -GB- / V07.00.0018/06/2004Elsa Win Vehicle Self-Diagnosis OBD Test Instruments Guided Fault Finding Guided FunctionsApplicationsAdministrationApplicationsAdministrationPrintShutdownPrintS295_018S295_135New keys from basic-CD 7.00 Help q Notes Please refer to the operating manual for the exact functions.q20VAS 5052 modesq qVAS 5053 modesq qVehicle Self-Diagnosis OBD (on-board diagnosis) Guided Fault Finding Guided Functions Administration Applications Elsa Win (not included)Vehicle Self-Diagnosis OBD (on-board diagnosis)q q q q qq q qGuided Functions Administration ApplicationsVAS 5052 Vehicle diagnosis and service information system Version -GB- / V07.00.0018/06/2004Elsa Win Vehicle Self-diagnosis OBDVAS 5053 Vehicle Diagnosis System Version -GB- / V07.00.0018/06/2004Vehicle Self-diagnosis OBDGuided Fault Finding Guided Functions Guided FunctionsApplicationsAdministrationApplicationsAdministrationPrintPrintS295_019S295_136Test Instruments If electrical measured values are required, they will have to be entered as substitute values using a virtual keyboard. If a measurement with the DSO is necessary, a message will appear stating that this measurement is only possible with the VAS 5051. Stored specified curves are displayed.Guided Fault Finding Function Check Test rear loudspeakers Check wiring harness Resistance measurement U/R/D measuring lead Multiple brown contact COM measuring lead brown contact Target valueVolkswagen V07.01.00 21.06.2004 3B - Passat 1997 2003 (3) Variant AWX 1.9l TD-PD 96kWModeGo toPrintS295_138/S295_17821Vehicle Self-DiagnosisThe diagnosis functions in the VAS 5051, 5051B, VAS 5052 and VAS 5053Overview After selecting the “Vehicle Self-Diagnosis” mode and choosing a vehicle system, the possible diagnosis functions of the vehicle system are queried once the communication between the VAS diagnosis system and the vehicle system is set up. If the vehicle has a diagnosis interface for data bus, only the diagnosis functions that are actually possible for the respective vehicle system will be displayed on the mask. On vehicles without a data bus diagnostic interface, all diagnosis functions that are possible with the VAS diagnosis system will be listed.Vehicle Self-Diagnosis Select diagnostic function01 - Engine electronics 03C906056F Hardware No MED9.5.10 00 5177 Code 72 Dealership number 0029502 - Query fault memory 03 - Control element diagnosis 04 - Basic setting 05 - Erase fault memory 06 - End output 07 - Sub-bus system code 08 - Read data block 10 - Adjustment 11 - Code II 15 - Readiness code 16 - Access authorisation Long adjustment Read challenge immobilizer IV Enable immobilizer IV Component protection Identification services Enable (PIN) Adjustment of channel 50 (PIN) Long adjustmentTest InstrumentsGo toPrintS295_020The necessary information on the repair group 01 vehicle self-diagnosis is only available in the ELSA in vehicles up to model year 1997. In vehicles from model year 1998, this information is available in the “Guided Fault Finding” or the “Guided Functions”.22After selecting the “Vehicle Self-Diagnosis” mode, the new functions “Collection Services” and “Gateway Component List” as well as ambient conditions are available depending on whether a data bus diagnosis interface is present. Collection Services After selecting the “Collection Services” function, the following diagnosis functions are available depending on whether a data bus diagnosis interface is present:qNew functions:q q qCollection Services Gateway Component List Ambient ConditionsVehicle Self-DiagnosisSelect vehicle systemQuery fault memory - Whole system This function allows you to query the fault memories of all systems installed in the vehicle. Query fault memory - Whole system* The fault memories of all vehicle systems entered in the screen mask “Select vehicle system” are deleted in succession. Switch on transport mode* In transport mode, almost all convenience functions are switched off so the maximum period out of operation without battery discharge is guaranteed. Switch off transport mode* This function is used to switch the convenience functions on again.qGateway Component List Collection Services 01 - Engine electronics 11 - Engine electronics II 21 - Engine electronics III 31 - Engine electronics system 41 - Diesel pumps electronics 51 - Electrical drive 61 – Battery regulation 71 - Battery charger 02- Gearbox electronics 12 - Clutch electronics 22 - Four-wheel drive electronicsTest Instruments Go to PrintS295_021qVehicle Self-diagnosis Collection Services Select diagnostic functionqQuery fault memory - Whole system Erase fault memory - Whole system Switch on transport mode Switch off transport modeTest InstrumentsGo toPrintS295_022* Only for vehicles with diagnosis interface for data bus23Vehicle Self-diagnosisGateway Component List After selecting the operating mode “Vehicle SelfDiagnosis”, the diagnosis function “Gateway Component List” is available for vehicles with diagnosis communication via the CAN data bus and the diagnosis interface for data bus (e.g. Audi A8 2003 , VW Touran 2003 , VW Golf 2004 ).Vehicle Self-DiagnosisSelect vehicle systemGateway Component List Collection Services 01 - Engine electronics 11 - Engine electronics II 21 - Engine electronics III 31 - Engine electronics system 41 - Diesel pumps electronics 51 - Electrical drive 61 - Battery regulation 71 - Battery charger 02- Gearbox electronics 12 - Clutch electronics 22 - Four-wheel drive electronicsTest Instruments Go to PrintS295_023Diagnosis communication via the data bus diagnostic interface VAS 5051VAS 5051/6A Diagnostics CAN data busCombi CAN data busVAS 5051/5A T16 VAS 5052Data bus diagnostic interfaceJ623 VAS 5052/3 VAS 5053 J104J217J386J387RJ526J431J388J389R78J635J234 Drive CAN data busG85J527J393J401R41Convenience CAN data busInfotainment CAN data busS295_02524When starting via the function “Gateway Component List”, a detailed list of the vehicle systems and their current status is read from the data bus diagnostic interface.Vehicle Self-Diagnosis Gateway Component List Communication SetupAudi V07.58.00 21/062004 Audi A8 2003 2004 (4) Saloon ASE 4.0 TDI / 200201 - Engine electronics OK 61 - Battery regulation Fault 02 - Gearbox electronics Not accessible 42 - Driver’s door electronics OK 52 - Front passenger’s door electronicsOK 62 - Rear left door electronics OK 72 - Rear right door electronics OK 03 - Brake electronics Fault 53 - Parking brake Not coded 34 - Adaptive suspension Not accessible 05 - Access and start authorisationFault 15 - Airbag OK 55 - Headlight range control Not codedTest Instruments Go to Print0000 0010 1100 0000 0000 0000 0000 0010 0001 1000 1010 0000 1011S295_024Status table Display in the Gateway Component List OK Meaning Bit sequenceThe control unit takes part in the data bus communication. No faults are stored in the control unit. The control unit is logged onto the gateway (coded), but there is no communication with the control unit.0000 Static 11xx Sporadic 1000 x010Cannot be accessed or no communications FaultAn error has been stored in the corresponding control unit. You can select the control unit and export the fault memory by touching the screen. The control unit is installed in the vehicle and takes part in data communication, but is not logged onto the data bus diagnostic interface (coded).Not logged in or not codedX0X1Several statuses cannot be shown at the same time for each vehicle system. Positions with an “X” are not evaluated and can display the values 0 or 1.25Vehicle Self-DiagnosisDisplaying the ambient conditions Some control units also store ambient conditions in addition to the fault memory entries. The ambient conditions can be displayed with the “Ambient Conditions” button if they are present in the “Read Fault Memory” diagnostic function.The “Ambient Conditions” button is only displayed if ambient conditions are actually stored.Vehicle Self-Diagnosis Fault memory content Query fault memory 8 Fault / notices recognised01 - Engine electronics 8E0907557 2.0L R4/5VS Code 11501 Dealership number 0029518010 P1602 Voltage supply terminal 30 Voltage too low Sporadic 17973 P1565 Throttle valve module - J338 Lower limit not reached002Position1Ambient ConditionsAmbient Conditions button008SortKilometresTimeSelection of sort method18395 P1987 001 Function limited by brake temperatureNotePriorityFrequencyTest InstrumentsGo toPrintS295_026Sort method The ambient conditions can be sorted manually according to the following categories:q q q qkm reading Time Priority Fault frequencyA “Note” label for the fault entry only appears from fault priority 6. The fault does not have to originate from the internal system. From basic CD 7.0 If no standard ambient conditions are stored, the screen colour may change.26Composition The ambient conditions are made up of standard ambient conditions and specific ambient conditions. Standard ambient conditionsq q q q qSpecific ambient conditionsqDate of first storage Time of first storage km reading for first stored fault Priority: Rating 1-8 Fault frequency: Counter up to 255 Number of definite cases since first occurrenceMeasured values specific to control unitVehicle Self-Diagnosis Fault memory content Query fault memory 8 Fault / notices recognised 17973 Throttle valve module - J338 Lower limit not reached Standard values: Date Time Kilometre reading Priority Fault frequency Error counter Measured values: Ignition angle Engine speed Battery voltageTest Instruments Go to01 - Engine electronics 8E0907557 2.0L R4/5VS Code 11501 Dealership number 00295 P1565 008Position107/03/04 10:05:17 35624 1 6 3Ambient ConditionsStandard ambient conditionsSortKilometres Time Priority FrequencySpecific ambient conditions27 ° 3550 rpm 11.7 VPrintPriority list Priority 1 2 3 4 5 6 7 8 Meaning for the vehicleS295_027Fault with great influence on the vehicle availability, the vehicle should be stopped immediately. Fault that requires direct visit to workshop. Fault that does not require an immediate visit to the workshop, but can be combined with a service appointment. Faults that lead to a required action, the vehicle availability may be limited in some cases (e.g. increased bias current) Fault without influence on the vehicle availability or not relevant to customer service. Note: Fault with long-duration influence on the vehicle availability and thus relevant to customer service (e.g. filling level, wear, ageing) Note: The fault has an influence on the convenience function, but no influence on the vehicle availability and is not relevant to customer service. General note27Test InstrumentsTest instruments in the VAS 5051The VAS 5051 has the “Test Instruments” mode. All measurements on pages 28 and 29 are described in SSP 202 “Vehicle Diagnosis, Testing and Information System VAS 5051” and can be checked there. They are only listed here for the sake of completeness.qVoltage measurement direct voltage max. 50 VqCurrent measurement Inline direct and alternating current measurement (measuring instrument connected in series) max. 10 AInline CurrentFreeze FrameTest Instruments MultimeterURD voltageFreeze FrameTest Instruments MultimeterMinimum MaximumMinimum MaximumVoltage URD Inline CurrentResistance URD Continuity Test URDDiode Test URDVoltage DSO 1 Current Trigger ClampPressure T/DTemperature T/DCalibrateVoltage URD Inline CurrentResistance URD Continuity Test URDDiode Test URDVoltage DSO 1 Current Trigger ClampPressure T/DTemperature T/DCalibrateGo toPrintGo toPrintS295_028S295_029qCurrent measurement Direct and alternating current measurement with trigger clamp 50 A, 100 A, 500 A or 1000 ACurrent 50A Trigger ClampFreeze FrameqResistance measurement Automatic or manual measuring range selectionResistance U/R/DFreeze FrameTest Instruments MultimeterTest Instruments MultimeterMinimum MaximumMinimum MaximumVoltage URD Inline CurrentResistance URD Continuity Test URDDiode Test URDVoltage DSO 1 Current Trigger ClampPressure T/DTemperature T/DCalibrateVoltage URD Inline CurrentResistance URD Continuity Test URDDiode Test URDVoltage DSO 1 Current Trigger ClampPressure T/DTemperature T/DCalibrateGo toPrintGo toPrintS295_030S295_03128qContinuity test Graphical display of results Connection Open circuitqDiode test Graphical display of results Diode in conducting direction Diode in blocking direction Short-circuit Open circuitTest Instruments MultimeterContinuity U/R/DFreeze FrameTest Instruments MultimeterDiode Test U/R/DFreeze FrameVoltage URD Inline CurrentResistance URD Continuity Test URDDiode test URDVoltage DSO 1 Current Trigger ClampPressure T/DTemperature T/DCalibrateVoltage URD Inline CurrentResistance URD Continuity Test URDDiode Test URDVoltage DSO 1 Current Trigger ClampPressure T/DTemperature T/DCalibrateGo toPrintGo toPrintS295_032S295_033qVoltage measurement with additional DSO probe (digital storage oscilloscope) up to +/- 400 VqDigital storage oscilloscope (DSO)Test Instruments MultimeterVoltage U/R/D Voltage DSO 1Freeze FrameTest Instruments DSOAuto-Level ModeFreeze Frame Channel AChannel BTrigger Mode Measuring ModeVoltage URD Inline CurrentResistance URD Continuity Test URDDiode test URDVoltage DSO 1 Current Current ProbePressure T/DTemperature T/DCalibrateBandwidth Limitation Position Go to Print Vehicle Self-Diagnosis Document Preset Measurement PrintGo toS295_034S295_03529Test InstrumentsIn the “Test Instruments” mode, new extensions are available.Parallel operation of the modes “Test Instruments”, “Vehicle Self-Diagnosis” and “OBD” It is possible to use the modes “Test Instruments”, “Vehicle Self-Diagnosis” and “OBD” parallel. Measured values from the “Vehicle Self-Diagnosis” and “OBD” modes can also be displayed cyclically in the masks “Multimeter” and “DSO” , the “Test Instruments” modes in addition to the measuring data and measuring curves. The following combinations are possible:qqqqMeasured values or measured curves from the “Test Instruments” mode and measured values from the “Read Data Block” function from the “Vehicle Self-Diagnosis” mode Measured values or measured curves from the “Test Instruments” mode and measured values from the “Basic Setting” function from the “Vehicle Self-Diagnosis” mode Measured values or measured curves from the “Test Instruments” mode and measured values from the “Control Element Diagnosis” function from the “Vehicle Self-Diagnosis” mode Measured values or measured curves from the “Test Instruments” mode and measured values from the “OBD” modeThe following functions are still recorded in the “Test Instruments” mode:q q qMin and max display in the “DSO” function Current measurement with the trigger clamp in the “DSO” function Long-time measurement in the “DSO” functionYou no longer switch over to the “DSO” function with the “DSO” button, but with the “Go to” button and then by selecting “DSO”.30Display of measured value blocks from the “Vehicle Self-Diagnosis” mode to the “Test Instruments” mode, “Multimeter” or “DSO” function So that the measured values from the “Read Data Block” and “Basic Setting” self-diagnosis functions are displayed in the “Test Instruments” mode, the “Read Data Block” or “Basic Setting” function and then a channel (e.g. 90) have to be selected in the “Vehicle Self-Diagnosis” mode. You then switch to the “Test Instruments” mode with the “Test Instruments” button. The “Multimeter” function is displayed automatically. The “DSO” function can be selected using the “Go to” button. After pressing the “Measured Value Self-Diagnosis” button, up to four measured values are displayed.“DSO” mask with display of a measured value block from the “Vehicle Self-Diagnosis”Test Instruments DSO Auto-Level Mode G40 Hall sender with standard coverFreeze FrameMeasured values from the vehicle self-diagnosisChannel A Channel B Measuring Mode Trigger Mode“Bandwidth Limitation” button (5051B only) The same measuring parameters are set as for the VAS 5051 so that the DSO images can be compared.Data block 90 from engine control unit0 rpm99%0 °Document0.0° after TDCPreset Measurement PrintBandwidth LimitationSelf-Diagnosis Measured ValuesVehicle Self-DiagnosisGo toRPMPulse duty factorAdjustment of targetAdjustment of actualS295_036“Measured Value Self-diagnosis” button“Vehicle Self-Diagnosis” button for switching between the “Vehicle Self-Diagnosis” and “Test Instruments” modes“Go to” button for selecting the “Multimeter” or “DSO” functionIf the measured values are not selected in “Vehicle Self-Diagnosis” mode, no measured values will be displayed in “Test Instruments” mode.31Test InstrumentsDisplay of control element value from the “Vehicle Self-Diagnosis” mode “Test Instruments” mode, “Multimeter” or “DSO” function To display values from the “Control Element Diagnosis” it is necessary to start the “Vehicle Self-Diagnosis” mode. Then you switch to the “Test Instruments” mode. In the “Multimeter” or “DSO” mask, you have to press the “Measured Value Self-Diagnosis” button. After returning to the “Vehicle Self-Diagnosis” mode, the control element of the required system can be started. Switching to the “Test Instruments” mode again displays the values obtained from the control element diagnosis.“DSO” mask with displayed values from control element diagnosis from the “Vehicle Self-Diagnosis”Test Instruments DSO Auto-Level Mode Injector N30Freeze Frame Channel AMeasured values from the vehicle self-diagnosisChannel B Measuring Mode Trigger Mode“Measured Value Self-Diagnosis” buttonData block 90 from engine control unit0 rpm99%0 °Document0.0° after TDCPreset Measurement PrintBandwidth LimitationMeasured Value Self-DiagnosisVehicle Go to Self-DiagnosisS295_037“Vehicle Self-Diagnosis” button for switching between the “Vehicle Self-Diagnosis” and “Test Instruments” modes“Go to” button for selecting the “Multimeter” or “DSO” functionTo select the next control element, return to “Vehicle Self-Diagnosis”.32Display of values from the “OBD” mode in the “Test Instruments” mode, “Multimeter” or “DSO” function The same rules apply as for the display of values from the mode “Vehicle Self-Diagnosis”, “Read Data Block” and “Basic Setting” function. There are, however, the following limitations: - Only the first four values are displayed when more than four OBD values are measured - Only the actual values without target value details are displayed“DSO” mask with display values from the OBDTest Instruments DSO Auto-Level Mode G40 Hall sender with standard coverFreeze Frame Channel AMeasured values from the OBDChannel B Measuring Mode Trigger Mode1140 rpm80° CDocument Preset Measurement PrintBandwidth LimitationMeasured Value Self-Diagnosis“Measured Value Self-Diagnosis” buttonVehicle Self-DiagnosisGo toS295_038“Vehicle Self-Diagnosis” button for switching between the “OBD” and “Test Instruments” modes“Go to” button for selecting the “Multimeter” or “DSO” function33Test InstrumentsCurrent measurement with the trigger clamp in the “Test Instruments” mode, “DSO” function The “DSO” function has been added to the test instruments. This expansion allows current values to be measured with the trigger clamp in the “DSO” function. The measuring range for the connected trigger clamp is set automatically by the VAS 5051. The recognition occurs via the coding resistor in the respective connector. The measurement can be in the DSO channel A or B, a parallel voltage measurement is possible using the channel that is not being used.“DSO” trigger clamp selection for current measurementTest Instruments DSO Auto ModeFreeze Frame Channel A Channel B Measuring SZ 50A SZ 100A SZ 500A SZ 1800A Pressure Temp KV DSO 2 DSO 1 Off Channel Coupling Preset Measurement Print Min / Max Trigger Mode Cursor 1 Cursor 2Self-Diagnosis Measured ValuesButton: Channel A for current measurement in the DSO Channel AVehicle Self-DiagnosisGo toButton: Min/max for displaying the minimum and maximum values at the bottom of the oscillogramS295_039Button: Channel for selection the test connection - Off - DSO 1 - DSO 2 - KV - Temp. - Pressure - SZ 1800A - SZ 500A - SZ 100A - SZ 50A Channel disabled DSO 1 measuring lead DSO 2 measuring lead Kilo-Volt probe (optional) Temperature sensor (optional) Pressure sensor (optional) Trigger clamp 1800 A (optional) Trigger clamp 500 A (optional) Trigger clamp 100 A Trigger clamp 50 AYou will find further information on use of the “Digital Storage Oscilloscope” function in SSP 202 “Vehicle Diagnostic, Testing and Information System VAS 5051” or in the operating manual for the VAS 5051.34Connecting the trigger clamp The line to be measured is held in the trigger clamp. To avoid incorrect measurements, the trigger clamp should be closed properly.Connecting the trigger clampS295_040VAS 5051Current probeMeasuring pointBefore carrying out a trigger clamp measurement, the trigger clamp has to be calibrated. This is automatic when you select a trigger clamp. The trigger clamp needs to be relieved, i.e. a cable cannot be held.35Test InstrumentsLong-time measurement in the “Test Instruments” mode, “DSO” function In the “Test Instruments” mode, function “DSO”, a long-duration measurement can be made in “Writer” measuring mode. Using the long-time measurement, voltage or current values can be recorded over several hours. This is recommended, for example, to test the sleep mode for CAN data bus systems, to check the bias current or other signals. The long-duration measurement is only possible in “Writer” measuring mode. It is selected by pressing the “Measuring Mode” button and the “Writer” button.“DSO” mask with button for setting the long-duration measurementTest Instruments DSO Writer ModeFreeze Frame Channel A Channel B Measuring Mode Long-Duration MeasurementButton: Measuring ModeButton: Long-Duration MeasurementBandwidth Limitation Auto Setup Auto Level Auto Normal Single WriterGo toPrintS295_041After pressing the “Writer” button the “Long-Duration Measurement” button appears.36Settings The long-duration measurement needs to be started manually. It can be stopped manually or after a specific time. Start/stop long-duration measurement The long-time measurement is started and stopped with the “Freeze Frame” button.qStart Deactivating the “Freeze Frame” button starts the long-duration measurement. The “Freeze Frame” button is deactivated when the button colour is light grey.qStop Activating the “Freeze Frame” button stops the long-duration measurement. The “Freeze Frame” button is activated when the button colour is dark grey.“DSO” mask with setting elements for long-duration measurementTest Instruments DSO Writer ModeFreeze Frame Channel A Channel BButton: Freeze FrameLong-Duration MeasurementHoursMinutes Time/Div.Go to PrintS295_042Increase measuring timeButtons: Hours/minutesShorten measuring timeMeasuring time The “Hours” and “Minutes” buttons can be used to set the running time of the long-duration measurement. During the measurement, the remaining time for the measurement is displayed in these buttons.37Test InstrumentsLong-duration measurement procedure During the measurement in writer mode, the running time is displayed at the top right of the mask. No changes can be made to the measurement settings. It can only be cancelled early by pressing the “Freeze Frame” button.“DSO” mask with setting elements for long-duration measurementTest Instruments DSO Writer Mode Recording time = 00:00:05Freeze Frame Channel A Channel BDisplay of running time“Freeze Frame” button for cancelling the measurement earlyHoursMinutes0002Go to PrintS295_043The measuring time The measuring time is limited depending on the resolution of the time axis.Resolution time axis 10 s/Div. 5 s/Div. 2 s/Div. 1 s/Div. 0.5 s/Div. 0.2 s/Div. 0.1 s/Div. 50 ms/Div. 20 ms/Div. 10 ms/Div. 5 ms/Div.Sampling rate 5 Hz 10 Hz 25 Hz 50 Hz 100 Hz 250 Hz 500 Hz 1 kHz 2.5 kHz 5 kHz 10 kHzRecording time duration in hh:mm 55:33 27:46 11:06 05:33 02:46 01:06 00:33 00:16 00:06 00:03 00:0138End of long-duration measurement The long-duration measurement ends once the set time has expired. The freeze frame function is switched on automatically and the signal pattern is displayed in the mask compressed. For a more precise assessment, a special area can be selected.“DSO” mask after ending the long-duration measurement “Long-duration measurement finished” displayTest Instruments DSO Writer Mode Long-duration measurement finishedFreeze Frame Channel A Channel BSelected areaLong-Duration Measurement Cursor 1 ZoomHoursMinutes0000Go to PrintS295_044Selecting the area to be enlarged By marking (tapping or touching) an area on the mask (screen) and then pressing the “Zoom” button, a section of the signals can be enlarged. When you press the button again, the zoom function is switched off. The cursors mark out the selected area. You can enlarge or reduce the area by moving the cursor.“DSO” with zoomed displayTest Instruments DSOWriter Mode Long-duration measurement finishedFreeze Frame Amplitude difference AAmplitude difference BTime differenceCursor 1Cursor 2Go toPrintS295_04539Test InstrumentsTest instrument adapters The adapters are used in conjunction with the VAS 5051 as well as the V.A.G 1715 and V.A.G 1526/1526A multimeters for simple, fast and safe detection of a wide range of electrical and electronic signals from components.S295_051Test instrument adapter/DSO (2-pole) VAS 5255 Use: Measurementsq qCircuit diagram Connector housing female Pin housing maleon injection valves on the solenoid valve for the activated charcoal filter systemMeasuring connectorsred greenS295_046Test instrument adapter/DSO (2-pole) VAS 5256 Use: Measurementsq qCircuit diagram Connector housing female Pin housing maleon ABS speed senders (inductive) on ABS speed senders (Hall sender)Measuring connectors red greenS295_04740Test instrument adapter/DSO (2-pole) VAS 5256/1 Due to the wide range of different ABS connectors, it was necessary to split the VAS 5256 adapter into the VAS 5256 and VAS 5256/1 adapters.Test instrument adapter/DSO (3-pole) VAS 5257 Use: Measurementsq qon engine speed sender on Hall senderCircuit diagram Connector housing female Pin housing maleCircuit diagram Connector housing female Pin housing maleMeasuring connectors red greenMeasuring connectors red green yellowS295_048S295_049Test instrument adapter/DSO (4-pole) VAS 5258 Use: MeasurementsqCircuit diagram Connector housing femalePin housing maleon coolant temperature senderMeasuring connectors red green yellow brownS295_05041Guided Fault FindingThe basic procedure for guided fault findingProcedure diagram Start mask 1Vehicleidentification, component list2Vehicle system test 3Run start module4Display fault memory content5Function/ component selection 126 Fault memory entries present? Complaints No 11Yes7 Test plan8 Function checkEnd guided fault finding9Run end module10S295_05242Guided Fault Finding The “Guided Fault Finding” allows you to repair faults that are entered in the fault memory as well as sort out complaints that should be rectified on the basis of perceptions. You are guided through the VAS diagnosis system and extensive tools are provided as required. Explanation 1 Start mask The guided fault finding is started from the start mask. 2 Vehicle identification The guided fault finding starts with selection of the brand. There is then a check to see whether the vehicle has a data bus diagnostic interface and therefore the specified component list can be read. The vehicle is then identified. 3 Vehicle identification, vehicle system test The vehicle system test follows. In a mask, all electronic vehicle systems that can occur under the basic features of the specific vehicle are displayed. Using the vehicle communications, there is a check to see which vehicle systems and variants are installed in the connected vehicle and their fault memories are read. 4 Run start module The start module can be started automatically in the “Guided Fault Finding” and before the fault memory entries are displayed. It can, for example, check the update status of control units and, if necessary, automatically initiate update programming or sendresults from the vehicle system test to the vehicle manufacturer via an online connection. 5 Fault memory content In this mask, the fault memory content and the associated fault text are listed according to control unit. 6 Fault memory entries If fault memory entries are present, the procedure will branch to the test plan or to the “Complaint Report” mask.43Guided Fault FindingProcedure diagram Start mask 1Vehicleidentification, component list2Vehicle system test 3Run start module4Display fault memory content5Function/ component selection 126 Fault memory entries present? No ComplaintsYes117 Test plan8 Function checkEnd guided fault finding9Run end module10S295_052447 Test plan When you switch to the “Test Plan” the results from the previous “Fault Memory Content” and “Complaint Reports” masks that have already been run through are evaluated and the system test plan is then created automatically. A separate test plan can also be created with the “Function and Component Selection”. Both test plans are displayed as a list. The result of a function check leads to a new assessment of the test plan. The list of function tests may grow here. 8 Function check A function check is a series of test steps to localise a fault to the level of individual components, cables and connectors or control units. As a result, the test program provides a statement on the state of the tested vehicle functions, modules or parts. The function test uses guide dialogs as an interface between the use and the diagnosis system and uses all functions of the vehicle self-diagnosis. The VAS 5051 incorporates the internal measuring instruments in the function test. When you are using the VAS 5052, these measurements have to be carried out with external test instruments. The respective function check dialogs allow you to enter substitute values manually. 9 Exiting “Guided Fault Finding” You exit the “Guided Fault Finding” with the “Go to” button. Among other things, it allows “Pause”, “Cancel” or “Exit” of the “Guided Fault Finding”. Pause This function allows you to pause or store the diagnostic steps briefly. Cancel The “Guided Fault Finding” mode is ended without being completed. You are taken back to the “Select Brand” mask. The fault memories are queries and erased. Exit This function ends the “Guided Fault Finding”. The fault memories of the vehicle systems are erased and then read again. If there are still error memory entries or new ones have been added, this will be displayed and the guided fault finding can be continued or cancelled. When the “Guided Fault Finding” is ended in OBD vehicles, there is a warning that the Readiness Code may have been deleted and you have the option of creating it again.45Guided Fault FindingProcedure diagram Start mask 1Vehicleidentification, component list2Vehicle system test 3Run start module4Display fault memory content5Function/ component selection 126 Fault memory entries present? No ComplaintsYes117 Test plan8 Function checkEnd guided fault finding9Run end module10S295_0524610 Run end module The end module is automatically started when you exit the “Guided Fault Finding” and can include one or more function checks that are carried out outside the test plan and are not entered there. Supports, for example, the automatic transfer of the diagnosis protocols via an online connection to the vehicle manufacturer. It is listed before the return to the start mask. 11 Technical problem solving/complaint If a fault is not recognised in the vehicle system test, the “Guided Fault Finding” will automatically switch to the selection of complaints. A symptom will have to be selected. Next the selected complaint is transferred to the test plan. You can switch to this step at any time by pressing the “Go to” button and selecting the fault memory symptom. 12 Function/component selection Here you can select functions or components that could be the source of the fault from experience. The selected functions and/or components are entered in the “User-Defined Test Plan” and the test can be started from there. If you press the “Go to” button and select “Document”, you can call up a document associated with the function or component.47Guided Fault FindingThe contents of the guided fault finding in the vehicle diagnosis, testing and information system VAS 5051 as well as in the vehicle diagnosis and service information system VAS 5052Overview Guided fault finding allows - vehicle specific query of the fault memory, - determining the cause of the fault with a dynamic fault finding program, - fault finding for a complaint related to the repair group or perception (HST/TPL), - the components and the function check via the “Go to” button, - the work time determination for the fault finding using the diagnosis protocol, - carrying out online functions and (e.g. software update of control units etc.), - erasing all fault memories upon exit. If there are still fault memory entries or new ones have been added, they will be displayed. If a fault was stored in the engine control unit of OBD vehicles, the readiness code will be deleted.Entry via the vehicle selectionGuided Fault Finding Vehicle Identification Select brand Guided Fault Finding Vehicle Identification Select typeS295_053Audi V07.58.00 21/06/2004 Guided Fault Finding Vehicle Identification Select model yearS295_054Audi V07.58.00 21/06/2004 Audi A8 2003 Volkswagen AudiS295_055 S295_056ModeAudi A2 2001 Audi A3 1997 2003 (3) Audi A3 2004 2004 (4) Audi A4 2001 Audi Cabriolet 2003 Audi A6 1998 Audi A8 1994 Audi A8 2003 Audi TT 1999 Remaining vehicles for online immobilizer Audi A4 USA 1995 Audi A4 USA 2001 Audi Cabriolet USA 2003 ModeGuided Fault Finding Vehicle Identification Select body shapeAudi V07.58.00 21/06/2004 Audi A8 2003 2004 (4) Guided Fault Finding Function/component selection Vehicle IdentificationSaloonAudi V07.58.00 21/06/2004 Audi A8 2003 2004 (4) SaloonASN 3.0l Motronic / 162 kW BBJ 3.0l Motronic / 160 kW ASB 3.0l TDI / 165 kW BFL 3.7l Motronic / 206 kW ASE 4.0l TDI / 202 kW BFM 4.2l Motronic / 246 kW BHT 6.0l Motronic / 331 kWModeModeModeGo toPrintS295_05748Querying all fault memories When the vehicle identification is targeted and correct, all electronic vehicle systems (control units) that could occur in the identified vehicle are displayed. In the communication with the vehicle, there is a check of which vehicle systems and variants are present and their fault memory is queried. All queried systems are indicated with a black bar.Once the query has been completed the following message appears:Please check that the recognised systems are complete. (black background)Fault memory queryGuided Fault Finding Function/component selection Vehicle IdentificationAudi V07.58.00 21/06/2004 Audi A8 2003 2004 (4) Saloon ASE 4.0l TDI / 202 kWIf an installed system cannot be recognised, it should be selected manually. Only then can the system components be accessed via the function/component selection.Fault19 - Data bus diagnostic interface 01 - Diesel direct injection and glow system (master) 11 - Diesel direct injection and glow system (slave) 02 - Automatic gearbox 09E 03 - ABS/EDS four-wheel drive Bosch 5.7 13 - Adaptive cruise control 34 - Adaptive suspension 53 - Parking brake 65 - Tyre pressure monitor 05 - Vehicle authorisation system 05 - Vehicle authorisation system with keyless entry 06 - Passenger side seat adjustment 07 - Front display/operating unit 07 - Front display/operating unit, Japan 08 - Automatic air conditioning 09 - Onboard supply 0E - Single CD player (pos. 1)Mode Go to PrintOKS295_059FaultFaultBy pressing the “OK” and “Continue”, the fault memory content is displayed.“Continue” buttonS295_077Status symbols in the vehicle system test Symbol Normal text Inverted text (black bar) Meaning Vehicle system displayControl unit not identified or deselected Control unit identifiedStatus lineFault memory empty — no fault set The control unit entered in the data bus diagnosis interface could not be recognised.FaultFault set in the fault memory Control unit does not have a communication interface Control unit selected manually Control unit deselected manually Control unit being queriedOn some vehicles, after the fault memory has been queried, you are requested to send the fault memory content to the Audi SVM via an online connection.49Guided Fault FindingFault memory content The fault memory content of the individual control units are displayed after switching to the “Fault Memory Content” mask. The fault code and the fault type are displayed in a standard company text. Using the “Ambient Conditions” button, standard and vehicle-specific conditions that occur when the fault occurs can be displayed.Address word and name of control unit Fault typeGuided Fault Finding Fault memory contentVW V6.55.00.14/01/2004 1T - Touran 2003 2004 (4) Saloon BKC 1.9l TDI-PD / 77kW “Ambient Conditions” button01 - Engine electronics 2 Fault / notice recognised 16497 P0113 000 Intake air temperature sender G42 Signal too large Fault not stored 16622 P0239 00 Charge air pressure signal too large 09 - Electronic central electrical system 3 Fault / notices recognisedAmbient ConditionsSort methodStandard Kilometres Static/ Sporadic TimeModeGo toPrintS295_060Fault codeFault code OBDSelection of sort methodOn the basic CD 7.0, it is possible to sort the fault order according to the standard ambient conditions stored in the control unit if the control unit supports this function. Faults for which no ambient conditionshave been stored are placed at the end and have a violet background.50Position You can switch between the individual faults with the UP and DOWN buttons. The order of the faults can change depending on the sort criterion. Sort method Standard Fault display in ascending address word order. Static/sporadic Faults are separated according to their status. Static (higher priority) are displayed at the top with a dark blue background, sporadic below them with a light blue background. Inside the status (colour), the fault frequency is taken as the second sort criterion (high counter figures first). Kilometres Sort method according to the km reading when the fault first occurred. The low readings first. Time Faults are listed chronologically according to when they first occurred. To allow better assignment, the fault that happened within the same minute are combined in coloured groups (alternately light and dark blue).Ambient conditions In the “Guided Fault Finding”, ambient conditions can be displayed using the “Fault Memory Contents” mask from basic CD 7.0. The vehicle system does need to support this function, however. After selecting the ambient conditions, the mask background colour changes depending on the type of fault, the sort method and the type of ambient conditions (standard or specific).Guided Fault Finding Fault memory contentVW V6.55.00.14/01/2004 1T - Touran 2003 2004 (4) Saloon BKC 1.9l TDI-PD / 77kWPosition of the fault in the complete fault memory print out “UP and DOWN” buttons01 - Engine electronics 16622 P0239 Charge air pressure signal too large Measured values Value 1 Value 2 Value 3 Value 4 Value 5 Value 6 Value 7 Value 800 Position“Sort” buttons1020 rpm 28 Nm 15 km/h 0.0 % 13.9 V 0001100 355 mg/H 0 mg/HSort MethodStandard Kilometres Static/ Sporadic TimeA violet background means that no standard, but only specific ambient conditions are stored. Mask with standard conditions see page 27.ModeGo toPrintS295_14051Guided Fault FindingTest plan If you continue, you can access the system test plan that is created by the VAS 5051 or by the VAS 5052. You can select a function check from the system test plans. The selected function test has a black background. The function check is started with the “Continue” button. The order is freely selectable if there are several function checks.Fault memory entries that are processed with this test planSelected function testGuided Fault Finding Test planVW V6.55.00.14/01/2004 1T - Touran 2003 2004 (4) Saloon BKC 1.9l TDI-PD / 77 kWSystem test plan 17 - Dash panel insert - Ambient temperature sensor - G17 Ambient temperature sensor - G17Own test plan OK read measured values G - Ambient temperature sensor - G17ModeGo toPrintS295_061Own test plan“Continue” button Start function testSystem test plan The “System Test Plan” is created automatically using the fault memory entries and/or complaint.User-defined test plan The “User-Defined Test Plan” can be created by the user via the function and component selection dialog.52Function test procedure The information and instructions required to rectify the fault are displayed to the operator in the form of message windows.Guided Fault Finding Function check Vehicle voltage terminal 30 Query fault memory The entry and start authorisation control unit -J518- has the following faults in the fault memory:FinishedVolkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Saloon BAN 6.0l 309 kWThe operator will be informed if he needs to continue manually.Vehicle voltage terminal 30 SV Fault code 00087 009 Open circuit / short-circuit after earthContinue with the Finished buttonModeGo toPrintS295_062“Finished” buttonThe remaining test procedure is function-guided.Guided Fault Finding Function check Vehicle voltage terminal 30 Vehicle voltage terminal 30 too lowVolkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Saloon BAN 6.0l 309 kWFinishedqThe battery voltage must be at least 11.5 VModeGo toPrintS295_063It contains instructions and information on the activities to be performed.Guided Fault Finding Function checkVolkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Vehicle voltage terminal 30 Saloon BAN 6.0l 309 kW Check onboard supply voltage at terminal 30 and 30SV Then check the voltage at terminal 30 and terminal 30SV for start-related consumers.FinishedTurn off the ignition and leave the key in the lock.Note: If the battery monitor control unit -J367 detects that the battery voltage is too low, only supply terminal 30 will be activated. Only if a minimum voltage of 9 V is reached,Mode Go to PrintS295_06453Guided Fault FindingIn the function checks, the necessary control unit information is incorporated in the “Guided Fault Finding”. This can be depicted on the display or also in the background by incorporating the basic conditions (e.g. measured values, state terminal 15 etc.).Guided Fault Finding Function check Vehicle voltage terminal 30 Test conditions Volkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Saloon BAN 6.0l 309 kWFinished1. Fuse AssignmentVoltage terminal 30 : 6.5 V (9.....14V9 The voltage at terminal 30 is too low Check the battery charge level Charge the battery if necessary Check the connector and the cable for terminal 30 between the control unit for access and start authorisation and battery. Also, using circuit diagram, check for loose contacts, moisture and corrosion.Mode Go to PrintS295_065Additional buttonSupporting literature Using an additional button that is only displayed when required, supporting information is displayed. The title of the documentation type is the same as the button label (e.g. Fuse Assignment).Guided Fault Finding Function check Vehicle voltage terminal 30 Voltage terminal 30 1. Fuse assignmentVolkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Saloon BAN 6.0l 309 kWModeGo toPrintS295_066For further information on “Guided Fault Finding”, use the CD “Guided Fault Finding with the Vehicle Diagnosis, Testing and Information System VAS 5051” and the operating manuals.54Diagnosis protocol A diagnosis protocol is created during each fault memory query or fault search in “Guided Fault Finding” mode. This protocol can be stored on the diagnosis system or sent online to the manufacturer database. Stored diagnosis protocols are sent automatically if the diagnosis system is connected to the network. Protocols that are older than forty days are deleted. The sent protocols are evaluated and frequently occurring fault memory entries can thus be recognised. This process is provides feedback information for the research and development department as well as for quality assurance To send the protocol, the diagnosis system needs to be connected to the network.Guided Fault Finding Function/component selection Vehicle IdentificationVolkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Saloon BAN 6.0l 309 kWImmobilizer Engine control unit 1 Motronic Engine control unit 2 Motronic Automatic 5-speed gearbox 01l Choice Automatic 6-speed gearbox 09L ABS/EDS/ASR/ESP - Bosch 5.7 four-wheel drive Brake servo Adaptive cruise control Should the diagnosis protocol Adaptive suspension for the finished diagnosis session Tyre pressure monitor be printed out? Airbag Battery regulation Climatronic Rear air-conditioning controls Yes Roof electronics Data bus diagnostic interface Parking aidMode Go to PrintFaultFaultFaultNoS295_177/S295_179Guided Fault Finding Function check Send diagnosis protocol Test conditionsVolkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Saloon BAN 6.0l 309 kWYes NoThis application sends the diagnosis protocol or stores it on the tester. If the tester is not connected to the network, the diagnosis protocol will be stored and then sent as soon as the tester is connected to the network. Protocols, which have been stored and are older than forty days, will be deleted automatically.Do you want to send the diagnosis protocol(s) now?ModeGo toPrintS295_160Various vehicle and operating data as well as information on the repair then need to be entered. Menus guide you through these entries.Guided Fault Finding Function check Vehicle voltage terminal 30 Test conditionsVolkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Saloon BAN 6.0l 309 kWFinished- Connect your tester to the corresponding hardware on your online network: - Then press the -FINISHED- buttonModeGo toPrintS295_16155Guided Fault FindingFunction/component selection In “Guided Fault Finding” mode, user-defined function or component checks can be selected via the “Go to” button and “Function/Component Selection”.Guided Fault Finding Fault memory content No fault recognisedVolkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Saloon BAN 6.0l 309 kWThe selected functions or components are sorted according to repair group. After selecting the repair group, the individual systems for which function and component checks can be carried out are displayed.Go to target Cancel Exit Vehicle System Test Fault Memory Symptoms Function/Component SelectionMode Go to PrintS295_067Volkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Saloon BAN 6.0l 309 kWGuided Fault Finding Function/Component Selection Select Function or ComponentDrive (rep. grp. 01; 10...26; 28...39) Chassis (rep. grp. 01; 40...49) Body (rep. grp. 01; 27; 50...97) Program Control Units VW Special Tools, Testing Equipment, AidsGuided Fault Finding Function/Component Selection Select Function or ComponentS295_068Volkswagen V06.50.00 23/02/2004 3D - Phaeton 2003 2004 (4) Saloon BAN 6.0l 309 kWDrive (rep. grp. 01; 10...26; 28...39) BAN - Engine Automatic 5-