TECHNICAL DOCUMENTATION

SSP 503 Supplementary heating systems Hydronic

PDFEN40 pages3 MB
SSP 503 Supplementary heating systems Hydronic - PDF cover

This PDF is currently unavailable.

Read document text
es, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nService TrainingAG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte is r o eo th u ra a c s sility ab y li an pt cerrectness of i t to the co nform spec at i h re o n wit in t hisSelf-study Programme 503do c um enht rig py Co t.agen lksw Vo byAG.Supplementary heating systems Hydronic B5S-F and D5S-F Design and FunctionProte cted by c o py rig ht . C op yi es, in part or in w l purpos hole ercia , is n m ot compe rm itte dun leAG. Volkswagen AG d agen oes ksw not l o V gu y b ara d nte ise r o eo h t u ra a c s sility ab y li an pt cerrectness of i t to the co nform spec a t i h re o n in wit thi sr te o iva r rp fo g ndo c um enThis self-study programme describes the workings and application of water-based supplementary heating systems Hydronic B5S-F and D5S-F produced by Eberspächer for the Touareg. It will give you an insight into the physical and control-related processes of these supplementary heating systems.The self-study programme describes the design and function of new developments. The contents will not be updated.For current testing, adjustment and repair instructions, refer to the relevant service literature.2ht rig py Co t.agen lksw Vo byAG.Prote cted byc o p yri gh t. C op yiS503_002Important Note ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Operation of the auxiliary heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5B5S-F/D5S-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Fuel supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24AG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e n is r o ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . te .e.or. . th u ac a s sCoolant circuit. . . . . . . . . . . . 26ility ab y li an pt ceHeating system management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28rrectness of i t to the co nform spec at i h re o n wit in t hisTest your knowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38es, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g ndo c um enht rig py Co t.agen lksw Vo byAG.Prote cted by c o py rig ht . C op yi3 IntroductionSupplementary heating systemsDepending on the purpose they are used for, supplementary heating systems are classified as supplementary heaters or auxiliary heaters.Supplementary heaterA supplementary heater has the task of increasing the vehicle's heating output in vehicles with a high degree of efficiency and consequently low heat output (diesel engines).Auxiliary heaterAuxiliary heaters have the task of heating the vehicle interior while the combustion engine is not operating.You can find out more about the differences between the supplementary heater and the auxiliary heater in their use as supplementary heating systems in the self-study programme no. 502 "Supplementary heating systems Thermo Top V and Thermo Top Fleece".Supplementary heating systems Hydronic B5S-F and D5S-F* B5S-F B – petrol, 5 – 5 kW output, S – auxiliary heater, F – flat ** D5S-F D – diesel, 5 – 5 kW output, S – auxiliary heater, F – flates, in part or in w l purpos hole ercia , is n m ot compe rm itte dun leAG. Volkswagen AG d agen oes ksw not l o V gufront left-hand y b The Hydronic B5S-F* and D5S-F** supplementary heating systems are installed on the ara d e nte is r o eo h Touareg above the wheel arch. A separate utfuel supply is fitted to link it to the fuel tank. ra a c s sside of theility ab y li an pt cerrectness of i t to the co nform spec a t i h re o n in wit thi sFuel liner te o iva r rp fo g nFuel tankdo c um enSupplementary heating systemS503_0084ht rig py Co t.agen lksw Vo byAG.Prote cted by c o py rig h t . Co py i Operation of the auxiliary heaterOperationThe following overview illustrates operation in simplified form using a supplementary heating system in a Touareg with Climatronic as an example.es, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nn AG. Volkswagen AG do es n wage s k l ot g o yV ua b ran ed s i tee r o h t or u ac a ssAuxiliary heaterility ab y li an pt cerrectness of i t to the co nform spec at i h re o n wit in t his"ON" buttonAerial and radio receiversFront air con. settingsRear settingsAuxiliary heater ExtrasAir conditioner operating unitdo c um enS503_010 Instant heating buttonRemote controlThe auxiliary heater can be switched on in three different ways: Option 1 Option 2 Option 3 – manually, via the touch screen or via the instant heating button on the Climatronic operating unit – automatically, via the switch-on timer on the touch screen – manually, via the remote controlagen lksw Vo byTouch screen for operating and display unit (in dash panel)AG.ht rig py Co t.Prote cted byc o p yri gh t . C op yi5 Operation of the auxiliary heaterOption 1–manually, via the touch screen or via the instant heating button on the Climatronic operating unitThe auxiliary heater can be immediately switched on manually via the touch screen or via the instant heating button on the Climatronic operating unit.Switching on via the touch screenThe "Climate" button is used to activate the "Air AG. Volkswagen AG d agen oes conditioning settings, front" menu. By touching ksw on the not l o gu yV Operating and display unit b ara d can open the "Auxiliary heater" function button, you e nte is r o e th or submenu for the auxiliary heater ac au settings. ss The "Activate immediately" function button can be used to immediately switch the auxiliary heater on or off.ility ab y li an pt ceurposes, in part or in wh ole, cial p is n mer m ot p o c erm or e t a itte v i r d pun lerrectne s s o f i t to the co n form spec atio h re n wit i n thi sd o c um enTouchscreenFront air con. settingsRear settingsAuxiliary heaterActivate nowr fo ngOperat. time immed. start Departure time 1 Departure time 2 Departure time 310 min.Auxiliary heater Monday1:50Switching on via the instant heating buttonThe auxiliary heater can also be immediately switched on or off manually via the instant heating button on the Climatronic operating unit.S503_077 Instant heating button6AG.12:00Sundayagen lksw Vo by12:00Wednesdayht rig py Co t.Prote cted by c o py rig ht . C op yiExtrasS503_076 Option 2 – automatically, via the switch-on timer on the touch screenProgramming the switch-on timeYou can program three starting times that are activated with or without a day of the week being specified. The active starting time is marked with a tick using the touch screen.Auxiliary heater Activate now Operat. time immed. start Departure time 1 Departure time 2 Departure time 3 10 min. 1:50 12:00 12:00 Monday Wednesday SundayWhen you select the time or day display, another submenu opens. The desired time and day of the week can be selected.Departure time 1 setting Time DayThe programmed starting time determines the time at which the set temperature should be reached in the vehicle. This is known as departure time programming.MondayAuxiliary heating/auxiliary ventilationurposes, in part or in wh ole, cial p is n mer m ot p o c erm or e t a itte v i r d pun leAG. Volkswagen AG d agen oes ksw not l o V gu y b ara d nte ise r o eo h t u ra a c s sS503_014The Climatronic control unit J255 automatically switches between "auxiliary heating" and "auxiliary ventilation". This is dependent on the difference between the ambient temperature and the desired temperature.ility ab y li an pt cerrectne s s o f i t to the co n form spec atio h re n wit i n thi sd o c um enSymbol for "auxiliary heater"If the "auxiliary heating" function is active and if the auxiliary heater is in heating mode, this will be indicated in the display of the air conditioner operating unit when the "auxiliary heater" symbol lights up.r fo nght rig py Co t.S503_046agen lksw Vo byAG.Prote cted byc o p yri gh t. C op yi7 Operation of the auxiliary heaterOption 3 – manually, via the remote controlThe instant heating function can be activated with the "ON" button on the remote control. The "OFF" button is used to switch off the heating. If the command is received correctly, a positive response sent to the remote control results in the indicator lamp lighting up green.Aerial "OFF" buttonS503_016 Indicator lamp "ON" buttonIndicator lamp displayMeaningn AG. Volkswagen AG do es n wage s k l ot Auxiliary o gu heater has been switched on. yV t b ara ed nte s i r o eo th ra au c ss Auxiliary heater has been switched off. tility ab y li an pt cees, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g ntAuxiliary heater remains off*.rrectness of i t to the co nform spec at i h re o n wit in t histAuxiliary heater remains on*.tAuxiliary heater remains off**.The total duration of individual flash codes varies. They are represented here schematically.t = Time *… no communication between remote control and radio receiver - the remote control is out of range - the remote control is in transport mode (not yet adapted)** … auxiliary heater is disabled; possible reasons include: - fuel tank is almost empty - vehicle battery voltage is too lowdo c um enChanging the batteryMore information is available in the owner's manual.S503_0178AG.If the indicator lamp in the remote control no longer lights when a button is pushed, the battery must be renewed.ht rig py Co t.agen lksw Vo byProte cted byc o p yri gh t . C op yi Remote control receiver for auxiliary coolant heater R149The radio signal from the remote control is received by the aerial R11 and is sent to the remote control receiver for auxiliary coolant heater R149. The radio receiver passes the signal to the auxiliary heater control unit J364 via an internal databus. The auxiliary heater then starts the auxiliary heater – in "auxiliary heating" or "auxiliary ventilation" mode. The aerial R11 is located inside the roof aerial. The remote control receiver for auxiliary coolant heater R149 is fitted in the roof liner at the rear.Remote control receiver for auxiliary coolant heater R149 Roof aerial with R11es, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nAG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte is r o eo th u ra a c s sility ab y li an pt ceS503_038rrectness of i t to the co nform spec at i h re o n wit in t hisAuxiliary heater with control unit J364Internal data busRemote controldo c um enht rig py Co t.agen lksw Vo byAG.Prote cted by c o py rig ht . C op yi9 B5S-F/D5S-FAG. Volkswagen AG d B5S-F/D5S-F agen oes n lkswTechnical featuresurposes, in part or in wh ole, cial p is n mer m ot p o c erm or e t a itte v i r d pun lesso yV db e ris tho auot g ua ran tee or acility ab y li an pt ceThe supplementary heating systems B5S-F (for petrol vehicles) and D5S-F (for diesel vehicles) can be operated as supplementary heaters or as auxiliary heaters. The mixture of fuel and air is created by a metal fleece. The structure of the B5S-F and D5S-F is largely the same; there are subtle differences, for example, in the design of the pipe for the fuel inlet. The nameplate shows whether it is a petrol or diesel variant.rrectne s s o f i t to the co n form spec atio h re n wit i n thi sd o c um enS503_007r fo ngTechnical dataHeat output Full load Partial load Fuel Power supply Nominal voltageOperating voltage range Electrical power consumption With circulation pump and vehicle blower – full load With circulation pump and vehicle blower – partial load Permissible operating pressure Fuel consumption Full load Partial load Undervoltage shut-offCO2 in the exhaust gas Weight Manufacturer10ht rig py Co t.agen lksw Vo byAG.Prote cted by c o py rig h t . Co py i5 000 W 2 300 W Petrol (DIN EN 228), diesel (DIN EN 590) Via starter battery 12 V 10.2 – 15.5 V 50 W 25 W 0.4 – 2.5 bar Petrol: 0.69 l/h and diesel: 0.62 l/h Petrol: 0.32 l/h and diesel: 0.27 l/h Undervoltage threshold for starting procedure - supplementary heater operation at 11.8 V Undervoltage threshold for starting procedure - auxiliary heater operation – petrol –9.8 V - auxiliary heater operation – diesel –10.0 V 8 – 12 % by vol. 2.9 kg Eberspächer es, in part or in w l purpos hole ercia , is n m ot comConnections of the supplementary heating systempe rm itte dun leAG. Volkswagen AG d agen oes ksw not l o V gu y b ara d nte ise r o eo h t u ra a c s sThis perspective view was chosen to show the individual connections of the supplementary heating system more clearly – it does not represent the actual installation position in the vehicle. The actual installation position is shown on page 4.ility ab y li an pt cerrectness of i t to the co nform spec a t i h re o n in wit thi sHeater coolant shut-off valve N279Coolant drainager te o iva r rp fo g ndo c um enElectrical connections of auxiliary heater control unit J364Circulation pump V55Coolant supplyTwo-zone and four-zone systems have different pipe arrangements. The figure shows the example of a two-zone system.ht rig py Co t.Fuel inletagen lksw Vo byAG.Prote cted byc o p yri gh t. C op yiSupplementary heating system B5S-F/D5S-FS503_02411 B5S-F/D5S-FOverview of componentsThis assembly overview shows the individual parts and sub-assemblies of the supplementary heating system B5S-F. Key1 2 3 4 5 6 7 8 9 10 Heat exchanger, outer part Compression spring for temperature sensor G18 Securing bolt Compression spring for temperature sensor 2 for supplementary and auxiliary heating G587 Securing bolt Temperature sensor G18 Temperature sensor 2 for supplementary and auxiliary heating G587 Heat exchanger, inner part Gasket Combustion inserturposes, in part or in wh ole, cial p is n mer m ot p o c erm or e t a itte v i r d pun leAG. Volkswagen AG d agen oes ksw not l o V gu y b ara d nte ise r o eo h t u ra a c s sility ab y li an pt cerrectne s s o f i t to the co n form spec atio h re n wit i n thi sd o c um enr fo ng12ht rig py Co t.agen lksw Vo byAG.Prote cted byc o p yri gh t. C op yi 11 12 13 14 15 16Gasket Combustion air blower V617un len AG. Volkswagen AG do wage s no for heater Q9 s 18 Glow e plug k l Cover for combustion air blower V6 o t gu yV b ara air blower V6 d 19 Lid for combustion e nte s Securing bolt i r eo ho t 20 Securing bolt u ra Electrical connections to the drive a motor of the c ssElectrical connections for the fuel pre-heating heater element Z66combustion air blower V6 Flame monitor G6421 22 23Auxiliary heater control unit J364 Lid for auxiliary heater control unit J364 Securing boltility ab y li an pt ceurposes, in part or in wh ole, cial p is n mer m ot p o c erm or e t a itte v i r d prrectne s s o f i t to the co n form spec atio h re n wit i n thi sd o c um enr fo nght rig py Co t.agen lksw Vo byAG.Prote cted byc o p yri gh t . C op yiS503_04213 B5S-F/D5S-FFunctional overviewAir supply for combustionThe air required for combustion is drawn into the combustion air housing by the combustion air blower fan and is channelled to the combustion air openings in the combustion chamber.Coolant connection - outletAuxiliary heater control unit J364 Fuel inletCombustion air blower V6es, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nAG. Volkswagen AG d agen oes ksw not l o V gu y b ara d nte ise r o eo h t u ra a c s sility ab y li an pt cerrectness of i t to the co nform spec at i h re o n wit in t hisGlow plug for heater Q9Fuel pre-heating heater element Z66Drive motor of combustion air blowerCombustion chamber Opening for combustion airdo c um enCombustion air inlet Exhaust gas outlet14ht rig py Co t.Opening for combustion airagen lksw Vo byAG.Prote cted byc o p yri gh t. C op yi Coolant connection - inflowes, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nn AG. Volkswagen AG do es n wage s k l ot g o yV ua b ran ed s i tee r o h t or u ac a The supplementary heating system ssFuel supply and combustionis supplied with fuel via the fuel inlet. The fuel inlet extends to the metal fleece. The fuel is pre-heated by the heating element. The fleece is hot enough to allow the fuel supplied to evaporate across the entire surface of the fleece. The combustion air is drawn in and fed via the combustion air openings to the combustion chamber. The evaporated fuel and the added combustion air form a flammable fuel/air mixture that is ignited by the glow plug. During the heating phase, no current is applied to the glow plug.ility ab y li an pt cerrectness of i t to the co nform spec at i h re o n wit in t hisTemperature sensor G18Temperature sensor 2 for supplementary and auxiliary heating G587Coolantht rig py Co t.The coolant enters the space between the heat exchanger inner part and the heat exchanger outer part via the coolant connection inlet. There, it absorbs heat via the wall of the inner part of the heat exchanger. The heated coolant enters the coolant circuit via the coolant connection outlet.agen lksw Vo byAG.do c um enHeat exchanger, outer partHeat exchanger, inner partFlame tubeS503_021Prote cted byc o p yri gh t . C op yi15 B5S-F/D5S-FCombustion air blower V6The three-part combustion air blower V6 is integrated into a separate housing. It is screwed to the heat exchanger outer part to form a single part. A fan draws in the combustion air needed for combustion and directs it to the burner insert. The fan is driven by a motor mounted immediately beneath the fan. To reduce noise, the cover of the combustion air blower is trimmed with insulating elements.AG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte is r o eo th u ra a c s sility ab y li an pt cees, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nLid for combustion air blowerrrectness of i t to the co nform spec at i h re o n wit in t hisInsulation element FanFlame monitor G64do c um enCover for combustion air blowerDrive motor of combustion air blowerCombustion air inlet Exhaust gas outlet Combustion air blower V616ht rig py Co t.agen lksw Vo byAG.Prote cted by c o py rig ht . C op yiCombustion air outletS503_050 Heat exchanger with burner inserturposes, in part or in wh ole, cial p is n mer m ot p o c erm or e t a itte v i r d pun leThe burner insert is inserted into the heat exchanger of the supplementary heating system. The combustion heat generated in the heat exchanger is absorbed by the coolant.AG. Volkswagen AG d agen oes ksw not l o V gu y b ara d nte ise r o eo h t u ra a c s sHeat exchanger, outer partCombustion insertility ab y li an pt cerrectne s s o f i t to the co n form spec atio h re n wit i n thi sd o c um enr fo ngS503_054Combustion insertThe combustion insert consists of the combustion chamber and the combustion tube. The metal fleece, the fuel preheating heater element Z66 and the glow plug Q9 are located in the combustion chamber. You can see the detailed position of the metal fleece in the cross-section of the interior structure of the burner insert on page 19.Fuel inletGlow plug for heater Q9Fuel pre-heating heater element Z66 Combustion tube Combustion chamberElectrical connecting line for Z66S503_053ht rig py Co t.agen lksw Vo byAG.Prote cted byc o p yri gh t. C op yi17 B5S-F/D5S-FGlow plug for heater Q9 and flame monitor G64The glow plug for heater Q9 is activated immediately after the supplementary heating system is switched on, and is supplied with current for approx. 120 seconds so it can pre-glow. It ignites the fuel/air mixture within 90 seconds of the fuel delivery being started. After the ignition phase, the glow plug is switched off. Flame monitor G64, which is fitted into the housing of the combustion air blower, performs the flame monitoring function. On switching off the supplementary heating system, the glow plug is switched on briefly within the run-on time, in order to remove combustion residues from it.es, in part or in w l purpos hole ercia , is n m ot compe rm itte dun leAG. Volkswagen AG d agen oes ksw not l o V gu y b ara d nte ise r o eo h t u ra a c s sility ab y li an pt cerrectness of i t to the co nform spec a t i h re o n in wit thi sr te o iva r rp fo g ndo c um enGlow plug for heater Q918ht rig py Co t.Flame monitor G64agen lksw Vo byc o p yri gh t. C op yiAG.Prote cted byS503_023 Mixture formationThe fuel passes via the fuel pump to the metal fleece. The metal fleece is pre-heated by the fuel pre-heating heater element Z66, allowing fast evaporation of the arriving fuel during the ignition phase. The combustion air required for the mixture is drawn in via the combustion air blower V6 and is fed into the burner insert via the air intakes for primary air. Here the fuel vapours mix with the primary air, and a combustible fuel/air mixture develops.Electrical connecting line for Z66Glow plug for heater Q9 Flame tube Combustion chamberFuel pre-heating heater element Z66AG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte is r o eo h ut ra a c s sFuel inletpe rm itte dility ab y li an pt cees, in part or in w l purpos hole ercia , is n m ot comun leAir inlet, secondary airrrectness of i t to the co nform spec a t i h re o n in wit thi sS503_022Electrical connecting line for Z66 Air inlet, primary airMetal fleecer te o iva r rp fo g ndo c um enht rig py Co t.agen lksw Vo byAG.Prote cted by c o py rig h t . Co py i19 B5S-F/D5S-FOperating phasesThe combustion process is controlled by the supplementary heating system control unit J364. It is divided into the following three phases:1. Starting phaseThe supplementary heating system is switched on. The combustion air blower starts up briefly. At the same time, the glow plug for heater Q9 and the fuel preheating heater element Z66 are activated.Glow plug for heater Q9es, in part or in w l purpos hole ercia , is n m m ot p o c erm or e t a itte iv r du rp o nl f e ngAG. Volkswagen AG d agen oes ksw not l o V gu y b ara d nte ise r o eo h t u ra a c s sility ab y li an pt ceS503_062Fuel pre-heating heater element Z66rrectness of i t to the co nf o r m spec atio h re n in wit2. Fuel distribution and evaporationThe combustion air blower V6 and metering pump V54 are activated. The quantity of fuel conveyed by the metering pump is distributed across the metal fleece. The fuel evaporates and mixes with the combustion air that enters via the air inlets for primary air. A combustible fuel/air mixture is formed.Metal fleecethi sd o cu m enEvaporated fuel Air inlet, primary air20ht rig py Co t.agen lksw Vo byAG.Prote cted byc o p yri gh t. C op yiS503_063 es, in part or in w l purpos hole ercia , is n m m ot p o c erm or e t a itte iv r du rp o nl f e ngAG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte is r o eo h ut ra a c s sility ab y li an pt ce3. Ignition phaseFuel/air mixture ignitedGlow plug for heater Q9rrectness of i t to the co nf o r m spec atio h re n in witThe glow plug for heater Q9 ignites this fuel/air mixture. An increased quantity of combustion air is now added to the combustion chamber from the combustion air blower V6, via both the air entries for primary air and the air entries for secondary air.thi sd o cu m enS503_064agen lksw Vo byAir inlet, secondary airAG.Air inlet, primary air4. Combustion phaseThe combustion phase is active. The flame spreads within the combustion chamber. The fuel pre-heating heater element Z66 and the glow plug for heater Q9 are switched off.Glow plug for heater Q9Combustion chamberS503_065 Fuel pre-heating heater element Z66ht rig py Co t.Prote cted by c o py rig h t . Co py i21 B5S-F/D5S-FHeat exchangeres, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nThe die-cast part and an outer part. There is a hollow space between the inner part and the outer part to allow the coolant to flow through. The housing inner wall of the inner part of the heat exchanger has axial ribbing; the housing outer wall of the inner part of the heat exchanger has spiral ribbing. The connections for coolant inlet and coolant outlet are located on the outer part of the heat exchanger. The temperature sensor G18 and the temperature sensor 2 for supplementary and auxiliary heating G587 are also installed in the outer part of the heat exchanger, near to the coolant inlet.rrectness of i t to the co nform spec at i h re o n wit in t hisility ab y li an pt cen AG. Volkswagen AG do es n wage s k l ot g o yV ua b ran ed s i tee r o h t or u a a s s aluminium heat exchanger is comprised of two parts, anc innerCoolant inletht rig py Co t.do c um enCoolant outletHeat exchanger, outer partRibbing – axialHeat exchanger, inner part22agen lksw Vo byAG.Prote cted byc o p yri gh t . C op yiTemperature sensor G18Temperature sensor 2 for supplementary and auxiliary heating G587S503_055 FunctionThe combustion heat is absorbed by the inner part of the heat exchanger. The axial ribbing on the inner wall guarantees good heat absorption. Heat is given off via the outer walls of the inner part of the heat exchanger to the coolant that is flowing around it. The ribbing running in a spiral shape on the outer wall of the inner part of the heat exchanger ensures optimum distribution and conduction of the coolant stream, to ensure that as much heat as possible can be absorbed as the coolant flows through. The heated coolant is directed to the heat exchanger in the heating/air-conditioning unit via the coolant circuit using the circulation pump V55 and the interior of the vehicle is heated up. The signals from the temperature sensor G18 and temperature sensor 2 for supplementary and auxiliary heating G587 are processed by the control unit J364.n AG. Volkswagen AG do es n wage s k l ot g o yV ua b ran ed s i tee r o h t or u ac a ssility ab y li an pt ceFor a detailed description on how to operate the supplementary heating system, see the chapter on the auxiliary heater control unit J364 page 28.es, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nrrectness of i t to the co nform spec at i h re o n wit in t hisCoolant outletCoolant inletTemperature sensor G18Ribbing – axialTemperature sensor 2 for supplementary and auxiliary heating G587ht rig py Co t.do c um enSpiral-shaped rippingAG.Heated housing wallS503_028 Heat exchanger, inner part Heat exchanger, outer part Cavityagen lksw Vo byProte cted byc o p yri gh t . C op yi23 Fuel supplyThe fuel supply systemSystem overviewThe fuel is pumped from the fuel tank by the metering pump V54 to the supplementary heating system via a separate line.Metering pump V54AG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte is r o eo th u ra a c s sility ab y li an pt ceurposes, in part or in wh ole, cial p is n mer m ot p o c erm or e t a itte v i r d pun lerrectne s s o f i t to the co n form spec atio h re n wit i n thi sd o c um enFuel delivery unitSwirl potSupplementary heating system B5S-F, D5S-FS503_025r fo ngYou can find out more about the schematic inner structure of a metering pump in the self-study programme no. 502 "Supplementary heating systems – Thermo Top V and Thermo Top Fleece".AG.24ht rig py Co t.agen lksw Vo byProte cted by c o py rig ht . C op yi The metering pump V54 is a combined system for the • • • delivery metering and also cut-off of the fueles, in part or in w l purpos hole ercia , is n m m ot p o c erm or e t a itte iv r du rp o nl f e ngMetering pumpAG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte is r o eo h ut ra a c s sility ab y li an pt cerrectness of i t to the co nf o r m spec atio h re n in witIt is actuated depending on the heat output stage and pumps/meters the fuel during the operating phase and cuts off the inflow of fuel after switching off the supplementary heating system. Effects upon failureS503_078thi sd o cu m enSupplementary heating system shut-offThe run-on phase starts after switching off manually or following the expiry of the maximum running time of the supplementary heating system. During the run-on phase, post-glowing is briefly carried out and the combustion air blower V6 and the circulation pump V55 continue to run in order to cool the heater unit. The duration of the runon phase is operating phase-related and may vary:Maximum run-on time:120 seconds when turning off the petrol supplementary heating system and 90 seconds for the diesel supplementary heating system.Minimum run-on time:60 seconds when turning off, for both the petrol and the diesel supplementary heating system.ht rig py Co t.agen lksw Vo byAG.Prote cted by c o py rig h t . Co py iIf the metering pump fails, the supplementary heating system system fails completely.25 Coolant circuitCoolant circuitThe simplified diagram describes how the supplementary heating system is integrated into the vehicle's coolant circuit.es, in part or in w l purpos hole ercia , is n m ot compe rm itte dun leAG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte is r o eo th u ra a c s sS503_029ility ab y li an pt cerrectness of i t to the co nform spec a t i h re o n in wit thi sr te o iva r rp fo g ndo c um en1 Coolant expansion tank 2 Circulation pump V55 3 Supplementary heating system 4 Cylinder block5 Heat exchanger*AG.6 Non-return valves7 Heater coolant shut-off valve N279* The graphic representation is used as a schematic example – in the case of four-zone heating systems, 2 heat exchangers are installed, for example.26ht rig py Co t.agen lksw Vo byProte cted by c o py rig ht . C op yiKey Heater coolant shut-off valve N279The shut-off valve is designed as a 3/2-way valve. That is why it makes it possible in auxiliary heater mode for the coolant to circulate only between the supplementary heating system and the heat exchanger for heating system (small coolant circuit). The coolant does not have to flow through the cylinder block, so it can heat up more quickly. The temperature in the vehicle interior can therefore rise more quickly. Effects upon failure If the shut-off valve N279 fails, the coolant circulates in the large coolant circuit. This ensures that the heat exchanger of the vehicle heating system is always supplied with warm coolant. It takes longer for the vehicle interior to heat up.Voltage supply for auxiliary heater control unit J364 N279To cylinder blockTo supplementary heating systemFrom heat exchanger for heating systemS503_071es, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nAG. Volkswagen AG d agen oes ksw not l o V gu y b ara d nte ise r o eo h t u ra a c s sility ab y li an pt cerrectness of i t to the co nform spec at i h re o n wit in t hisCirculation pump V55The circulation pump V55 is part of the heater assembly. It circulates the coolant in the heater. It pumps the coolant coming from the heat exchanger of the heating system to the heater. Effects upon failureVoltage supply for auxiliary heater control unit J364 V55 To supplementary heating systemS503_036 From heat exchanger for heating systemht rig py Co t.agen lksw Vo byAG.Prote cted byc o p yri gh t. C op yiIf the circulation pump V55 fails, the supplementary heating system is switched off. This prevents the supplementary heating system from overheating due to the lack of coolant circulation.do c um en27 Heating system managementAuxiliary heater control unit J364The auxiliary heater control unit J364 is installed under a plastic cover on the heat exchanger housing.w The control unit is the same design for both the V petrol olks y b ed and diesel versions, as well as for both the ris ho t u supplementary and auxiliary heater function. saAG. Volkswagen AG d agen oesAll functions relevant to the different combustion processes are controlled in the control unit: • • • Output of the V6 combustion air blower Metering pump V54 cycle frequency Actuation of the glow plug for heater Q9 Effects upon failurees, in part or in w l purpos hole ercia , is n m m ot p o c erm or e t a itte iv r du rp o nl f e ngsnot gu ara nte eo ra cility ab y li an pt cerrectness of i t to the co nf o r m spec atio h re n in witS503_057It also controls the shut-off valve.The control unit can be replaced separately.If the control unit fails, the supplementary heating system fails completely.thi sd o cu m enAuxiliary heater control unit J364S503_04728ht rig py Co t.agen lksw Vo byAG.Prote cted by c o py rig ht . C op yi es, in part or in w l purpos hole ercia , is n m ot comThe temperature sensor G18 and the temperature sensor 2 for supplementary and auxiliary heating G587pe rm itte drrectness of i t to the co nform spec a t i h re o n in wit thi sEffects upon failureagen lksw Vo byAG.If the temperature sensors G18 and G587 fail, the system is switched off.The retaining clip for G587 is used for electromagnetic shielding of the control unit J364.Retaining clip for G587ht rig py Co t.The temperature sensor G18 is inserted into the outer part of the heat exchanger. Temperature sensor 2 for supplementary and auxiliary heating G587 is inserted and secured with a retaining clip. Both temperature sensors are NTC resistors whose signals are used by the control unit J364 for the purposes of overheating monitoring. The temperature sensor G18 monitors the coolant temperature during heating mode. Temperature sensor 2 for supplementary and auxiliary heating G587 monitors the coolant temperature and regulates the heating levels in supplementary and auxiliary heater operation.r te o iva r rp fo g nun leAG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte is r o eo h ut ra a c s sility ab y li an pt ceS503_058do c um enProte cted by c o py rig h t . Co py iTemperature sensor G18Temperature sensor G587S503_04829 Heating system managementSystem overviewJ255 J685 c V305E537 J285 J533 b Diagnostic connection e G18 Q9 Z66 a J364 V6 N279J794G587V54 G64 dR149pe rm itte dun leAG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte S503_059 is r o eo h t ra au c s sV55ility ab y li an pt cea b c d eCAN instrument cluster data bus Diagnosis CAN bus LIN data busline Internal data bus Most data busActuator line Sensor linerrectness of i t to the co nform spec a t i h re o n in wit thi sKeyE537 G18 G64 G587 J255 J285 J364 J533The instant heating button in the air conditioner operating unit Temperature sensor Flame monitorr te o iva r rp fo g nes, in part or in w l purpos hole ercia , is n m ot comJ685 J794 N279 Q9 R149 V6 V54 V55 V305 Z66AG.Display unit for front information display and operating unit control unit Control unit 1 for information electronics Heater coolant shut-off valve Glow plug for heaterdo c um enTemperature sensor 2 for supplementary and auxiliary heating Climatronic control unit Control unit in dash panel insert Data bus diagnostic interfaceProte cted by c o py rig h t . Co py iRemote control receiver for auxiliary coolant heater Combustion air blower Metering pumpht rig py Co t.Auxiliary heater control unitRecirculating pump Motor for front Bitron blower regulation Fuel pre-heating heater element30agen lksw Vo by Switch-on conditionsSupplementary heater• • • • • • • • • Coolant temperature: t 76 °C Ambient temperature: t 5 °C Terminal 15 (ignition): on Engine speed: n 300 rpm Temperature preselection: not set to "cold" Reserve fuel operation: no Vehicle electrical system: load management not activated Crash switch-off: no crash signal present from the airbag control unit Fault memory entries: no entries that prevent starting present, e.g. electronic control unit lockingAuxiliary heater• • • • Reserve fuel operation: no Undervoltage deactivation: no undervoltage present Crash switch-off: no crash signal present from the airbag control unit Fault memory entries: no entries that prevent starting present, e.g. electronic control unit lockingn AG. V Deactivation conditions wage olkses, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g n• •olkswagen AG does not gu yV b ara d nte ise r o eo Supplementary h heater: engine speed n 300 rpm t u ra a c Fault memory entries: there are entries that ssility ab y li an pt ce• • • •••agen lksw Vo byAG.Prote cted byc o p yri gh t . C op yi•ht rig py Co t.prevent starting present, e.g. electronic control unit locking Undervoltage shut-off: U 11.3 V for more than 250 seconds Vehicle electrical system: load management activated Crash switch-off: crash signal present from the airbag control unit Reserve fuel operation: only taken into consideration prior to starting (residual fuel quantity less than 7 litres) Supplementary heater: temperature preselection set to "cold" Auxiliary heater: preselection time expired, switched off manually or max. operating time reached – after a running time of 60 minutes Coolant temperature 88 °Crrectness of i t to the co nform spec at i h re o n wit in t hisdo c um en31 Heating system managementComponent activationSupplementary heating system for petrol B5S-FInitial start of auxiliary heating1. The combustion air blower V6 starts up briefly to test the functionality, and is then switched off again. 2. At the same time, the glow plug for heater Q9 is provided with 100% power. 3. Shortly afterwards, the fuel pre-heating heater element Z66 starts. 4. The rotational speed of the combustion air blower V6 is now increased. 5. The metering pump V54 starts and increases the flowrate. 6. The fuel pre-heating heater element Z66 is switched off. 7. Once the flame is burning in a stable manner, the glow plug for heater Q9 is switched off gradually. 8. Full load operation starts.Combustion air blower V6 (V) Metering pump V54 (Hz)es, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nn AG. Volkswagen AG do e wage s k l Time (s)s not o gu yV b ara ed nte ris o eo h t u ra a c ssS503_004Load change (partial load – full load – partial load)9. Once the coolant has reached a certain temperature, the heater switches to partial-load operation. The combustion air blower V6 and the metering pump V54 are in partialload operation.32AG.Prote cted by11. The coolant has reached the control temperature and regular operation recommences.Time (s)ht rig py Co t.agen lksw Vo byc o p yri gh t . C op yi10. If the coolant temperature goes below a certain level, the heater, and thus the combustion air blower V6 and the metering pump V54 switch from partial-load to full-load operation.Combustion air blower V6 (V) Metering pump V54 (Hz)S503_072Glow plug Q9 (W) Heater element Z66 (W)ility ab y li an pt cerrectness of i t to the co nform spec at i h re o n wit in t hisdo c um en Run-on12. When the heater is switched off, the run-on phase starts. The glow plug for the heater Q9 continues to glow briefly and is switched off gradually to burn off combustion residues. 13. The combustion air blower V6 is turned off. 14. In the last phase, the combustion air blower V6 is restarted in order to cool the components of the heater.Combustion air blower V6 (V)Time (s)S503_074Combustion air blower V6AG. Volkswagen AG V54 does agen Metering pump ksw not l o gu yV Fuel pre-heating heater element Z66 b ara d e nte is r o e Glow plug for heater Q9 th or ac au sses, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nThe curves in the diagrams refer to basic procedures. Actual procedures depend on factors such as the ambient temperature, the supply voltage and the time of flame detection. Please look up vehicle-specific data for actuating the components in the current repair guideline.do c um enGlow plug Q9 (W)ility ab y li an pt cerrectness of i t to the co nform spec at i h re o n wit in t hisht rig py Co t.agen lksw Vo byAG.Prote cted by c o py rig ht . C op yi33 Heating system managementSupplementary heating system for diesel D5S-FInitial start of auxiliary heating1. The combustion air blower V6 starts up briefly to test the functionality, and is then switched off again. 2. At the same time, the glow plug for heater Q9 is provided with 100% power. 3. At the same time, the fuel pre-heating heater element Z66 is started and it is turned of again gradually. 4. The metering pump V54 starts and increases the flow-rate gradually. 5. The rotational speed of the combustion air blower V6 is now increased. 6. Once the flame is burning in a stable manner, the glow plug for heater Q9 is switched off gradually. 7. The fuel pre-heating heater element Z66 is switched off. 8. Full load operation starts.un leCombustion air blower V6 (V) Metering pump V54 (Hz)Time (s)S503_005AG. Volkswagen AG d agen oes ksw not l o V gu y b ara d nte ise r o eo h t u ra a c s ses, in part or in w l purpos hole ercia , is n m ot compe rm itte dLoad change (partial load – full load – partial load)9. Once the coolant has reached a certain temperature, the heater switches to partial-load operation. The combustion air blower V6 and the metering pump V54 are in partialload operation. 10. If the coolant temperature goes below a certain level, the heater, and thus the combustion air blower V6 and the metering pump 54 switch from partialload to full-load operation. 11. The coolant has reached the control temperature and regular operation recommences.r te o iva r rp fo g nCombustion air blower V6 (V) Metering pump V54 (Hz)34ht rig py Co t.Time (s)S503_073Glow plug Q9 (W) Heater element Z66 (W)ility ab y li an pt cerrectness of i t to the co nform spec a t i h re o n in wit thi sdo c um enagen lksw Vo byAG.Prote cted byc o p yri gh t. C op yi Run-on12. When the heater is switched off, the run-on phase starts. The glow plug for the heater Q9 continues to glow briefly and is switched off gradually to AG. Volkswagen AG d agen oes ksw not l burn off combustion residues. o g yVCombustion air blower V6 (V)14. The combustion air blower V6 is turned off. 15. In the last phase, the combustion air blower V6 is restarted in order to cool the components of the heater.es, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g n13. At the same time, the fuel pre-heating ise or h t heater element Z66 is actuated u briefly sa to evaporate combustion s residue from the fleece.dbua ran teeor acility ab y li an pt ceTime (s)S503_075Combustion air blower V6 Metering pump V54 Glow plug for heater Q9ht rig py Co t.Fuel pre-heating heater element Z66The curves in the diagrams refer to basic procedures. Actual procedures depend on factors such as the ambient temperature, the supply voltage and the time of flame detection. Please look up vehicle-specific data for actuating the components in the current repair guideline.Glow plug Q9 (W) Heater element Z66 (W)rrectness of i t to the co nform spec at i h re o n wit in t hisdo c um enagen lksw Vo byAG.Prote cted by c o py rig ht . C op yi35 Heating system managementNetworking – auxiliary heater and supplementary heaterData bus messagesMOST busJ519 Onboard supply control unitJ234 Airbag control unitJ623 Engine control unit• • •Ambient temperature•Crash signal• • •Engine speed Coolant temperature Fuel type, petrol/diesel Status, start/stop Elevation informationJ533 Data bus diagnostic interfacepe rm itte dR149 Remote control receiver for auxiliary coolant heaterun len AG. Volkswagen AG do es n wage s k l ot g o yV ua b ran ed s i tee r o h t or u ac a ss• • • • • • • • • •es, in part or in w l purpos hole ercia , is n m ot com•Radio signal on/offDeparture time Diagnosis Supplementary heater authorisation Engine speed Time/date Crash signal Fuel type, petrol/diesel Status, start/stop Coolant temperature Elevation informationJ285 Control unit in dash panel insertility ab y li an pt cerrectness of i t to the co nform spec a t i h re o n in wit thi s•LED statusr te o iva r rp fo g nJ364 Auxiliary heater control unitht rig py Co t.do c um enAG.36agen lksw Vo byProte cted byc o p yri gh t . C op yi es, in part or in w l purpos hole ercia , is n m ot p om c r erm o e t a itte riv du p or nl f e g nn AG. Volkswagen AG do es n wage s k l ot g o yV ua b ran ed s i tee r o h t or u ac a ssility ab y li an pt cerrectness of i t to the co nform spec at i h re o n wit in t hisJ533 (all CANs)Powertrain CAN data busInternal data busCAN instrument cluster data busConvenience CAN data busData bus messagesJ685 Display and operating unitdo c um en• •••Time•Status of auxiliary heater•Time•• •Fuel tank warning Period out of use• • • •Status of auxiliary heater/ auxiliary ventilator Actuation of auxiliary heater Period of operation Timer status Status of circulation pumpht rig py Co t.•Status of auxiliary heater mode Request for fuel pump Information "Engine pre-heated"c o p yri gh t . C op yi•Menu display/data Timeagen lksw Vo by• •Menu display/data TimeAG.Prote cted by•Ambient temperatureJ255 Climatronic control unit• • • • •Radio signal on/off LED status Timer status Status of operation duration Heat outputS503_06137 Test your knowledgeWhich answers are correct? One or several of the given answers may be correct. 1. Where can the "auxiliary heater" and "auxiliary ventilation" functions be set? a) In the "Air conditioning settings, front" menu.❒ ❒ ❒2.es, in part or in w l purpos hole ercia , is n m m ot p o c erm or e t a itte iv r du rp o nl f e ngAG. Volkswagen AG d agen oes ksw not l o V gu y b ara b) In the "Programming the switch-on time" menu. d nte ise r o eo h t u ra a s s c) Switching takes place automatically in the control unit of ctheair conditioning system.ility ab y li an pt ceWhich of the following statements is correct?rrectness of i t to the co nf o r m spec atio h re n in wit❒ ❒ ❒a) The glow plug for the heater in the supplementary heating system B5S-F has the designation Q8. b) The glow plug for the heater in the supplementary heating system B5S-F has the designation Q9. c) The glow plug for the heater in the supplementary heating system B5S-F has the designation Q9 and also has the function of flame monitoring.3.The supplementary heating system D5S-F... a) works with a burner with venturi technology. b) works with a burner with fleece technology. c) works with a burner with pre-combustion.AG.Prote cted bythi sd o cu m en❒ ❒ ❒4.The remote control receiver for auxiliary coolant heater R149 on the Touareg is, from model year 2011 ... a) installed in the roof lining at the rear. b) integrated into the Climatronic control unit J225. c) installed behind side panel on the right-hand side in the luggage space.❒ ❒ ❒38ht rig py Co t.agen lksw Vo byc o p yri gh t. C op yi 5.The metering pump V54 has the task of ... a) metering the required amount of fuel needed for the current load status of the heater. b) keeping the fuel constantly in a ring-shaped line to provide additional cooling for the heater.s no ksw heater operation. c) supplying the heater with fuel only during auxiliary t gu Vol by ara d e nte s In supplementary heater operation, the i heater is supplied by the fuel line of the engine. or❒ ❒ ❒AG. Volkswagen AG d agen oe6.Which component is controlled by the auxiliary heater control unit J364? a) The flame monitor G64.❒ ❒ ❒7.es, in part or in w l purpos hole ercia , is n m m ot p o c erm or e t a itte iv r du rp o nl f e ngth au s seo ra cility ab y li an pt cerrectness of i t to the co nf o r m spec atio h re n in witb) The metering pump V54.c) The remote control receiver for auxiliary coolant heater R149.Which of the following statements is correct?❒ ❒ ❒8.a) The auxiliary heater can be started using the instant heating button, even when operating in reserve fuel mode.thi sd o cu m enb) The control unit J364 controls the output of the combustion air blower V6.ht rig py Co t.c) The control unit J364 can only be replaced in conjunction with this combustion air blower.agen lksw Vo byAG.Prote cted byIn which order do the phases of starting the supplementary heater occur? a) Pre-glow phase, ignition phase, combustion phase. b) Evaporation phase, ignition phase, combustion phase. c) Pre-glow phase, evaporation phase, ignition phase, combustion phase.❒ ❒ ❒Solution: 1. c); 2. b); 3. b); 4. a); 5. a); 6. b); 7. b); 8. c)c o p yri gh t. C op yi39 503es, in part or in w l purpos hole ercia , is n m ot compe rm itte dun leAG. Volkswagen AG d agen oes ksw not l o gu yV b ara d e nte is r o eo th u ra a c s sility ab y li an pt cerrectness of i t to the co nform spec a t i h re o n in wit thi sr te o iva r rp fo g ndo c um en© VOLKSWAGEN AG, Wolfsburg All rights and rights to make technical alterations reserved. 000.2812.60.20 Technical status 04/2013 Volkswagen AG After Sales Qualifizierung Service Training VSQ/2 Brieffach 1995 D-38436 Wolfsburg❀ This paper was manufactured from pulp that was bleached without the use of chlorine.ht rig py Co t.agen lksw Vo byAG.Prote cted by c o py rig ht . C op yi