TECHNICAL DOCUMENTATION

SSP 621 Audi A3 Sportback g-tron

PDFEN40 pages6 MB
SSP 621 Audi A3 Sportback g-tron - PDF cover

This PDF is currently unavailable.

Read document text
Self Study Programme 621 For internal use onlyAudi A3 Sportback g-tronAudi Service Training The Audi A3 Sportback g-tron showcases state-of-the-art CNG drive technology, starting with the fuel storage. Its two tanks under the luggage compartment floor can each hold 7.2 kg of CNG at a maximum 200 bar pressure referred to 15 °C. In keeping with Audi's ultra-lightweight construction principle, each tank weighs 27 kg less than its conventional steel counterpart. The CNG tanks made from an enhanced plastic matrix. A gas-impermeable polyamide polymer forms the inner layer, while a second layer of carbon fiber-reinforced polymer (CFRP) gives the tank its extremely high strength; a third layer of glass fiber reinforced polymer (GFRP) provides protection against exterior damage. High-strength epoxy resin is used to bind the fibrereinforced materials. The electronic gas pressure regulator reduces the high pressure of the gas flowing from the CNG tanks down to around five to nine bar in two stages. This ensures that the right pressure is always present in the injector rail and at the injector valves. If the pressure in the CNG tanks drops below the required level, the engine management system automatically switches to petrol operation. After refueling, and whenever it is very cold, the engine is started with petrol initially, then it switches over to CNG.The engine in the Audi A3 Sportback g-tron is based on the 90 kW 1.4 TFSI. Modifications were made to the cylinder head, turbocharging, injection system, and the catalytic converter. Developing 81 kW (110 hp) and 200 Nm of torque, the Audi A3 Sportback g-tron has a top speed of 190 kph, with 0 to 100 kph taking eleven seconds. The five-door model consumes on average less than 3.5 kg per 100 km of CNG. CO2 tailpipe emissions are less than 95 grams per km in gas mode.e-media This SSP contains QR codes which you can use to access additional interactive content see page 39.621_004Learning objectives of this self study programme: This Self-Study Programme provides you with information about the CNG system in the Audi A3 Sportback g-tron. Once you have completed this Self Study Programme you will be able to answer the following questions: • What are the components of the CNG system? • How is authorised to carry out work on the CNG system? • How do you identify an Audi A3 Sportback g-tron?2!Note The graphics and illustrations shown in this self study programme are basic representations and are given to help understand concepts. ContentsIntroductionQualification __________________________________________________________________________________________________________________________________________________ Natural gas ___________________________________________________________________________________________________________________________________________________ Audi e-gas project ____________________________________________________________________________________________________________________________________________ Vehicle distinguishing features _____________________________________________________________________________________________________________________________ 4 5 6 8Engine mechanicals1.4l TFSI engine of the EA211 series (81 kW) ___________________________________________________________________________________________________________ 10 Comparison of torque/power curves ______________________________________________________________________________________________________________________ 11CNG driveOverview _____________________________________________________________________________________________________________________________________________________ 12 CNG filler neck _ ______________________________________________________________________________________________________________________________________________ 14 CNG lines _____________________________________________________________________________________________________________________________________________________ 15 Distributor with non-return valve _________________________________________________________________________________________________________________________ 15 CNG tank _____________________________________________________________________________________________________________________________________________________ 16 Tank shut-off valves _________________________________________________________________________________________________________________________________________ 19 Gas pressure regulator _____________________________________________________________________________________________________________________________________ 24 Gas distributor rail __________________________________________________________________________________________________________________________________________ 29Engine management systemSensors and actuators ______________________________________________________________________________________________________________________________________ 30 Engine management control unit J623 ___________________________________________________________________________________________________________________ 32 Operating strategy __________________________________________________________________________________________________________________________________________ 32DisplaysInstrument cluster __________________________________________________________________________________________________________________________________________ 34ServiceSpecial tools and workshop equipment _ __________________________________________________________________________________________________________________ 35AnnexTest your knowledge ________________________________________________________________________________________________________________________________________ 37 Self Study Programmes ____________________________________________________________________________________________________________________________________ 39 Information on QR codes _ __________________________________________________________________________________________________________________________________ 39The Self Study Programme teaches a basic knowledge of the design and mode of operation of new models, new automotive components or new technologies. It is not a Repair Manual! Figures are given for explanatory purposes only and refer to the data valid at the time of preparation of the SSP. This content is not updated. For further information on maintenance and repair work, always refer to the current technical literature.!NoteReference3 IntroductionQualificationSpecial qualifications are required to be able to service and provide technical support for the Audi A3 Sportback g-tron within the Audi organisation. Given the different requirements and regulations relating to the handling of CNG-powered vehicles, it is necessary to provide basic qualification in accordance with the national regulations in force in your country. For information on specific qualification requirements, please contact the relevant authorities and institutions in your country. For the purposes of qualification within the Audi organisation, AUDI AG will provide importers with an expert training module covering the special technology of the Audi A3 Sportback g-tron.Instruction!TrainingIn some countries, employers are obligated to exercise due care by advising employees of workshop hazards and provide instruction. Even in countries where this obligation does not apply, AUDI AG requires that employers provide instruction. Personnel who carry out work on an Audi A3 Sportback g-tron, but not on the gas system,and/or are entrusted with handling an Audi A3 Sportback g-tron, must have received instruction. Country-specific regulations must be observed.! !Work on the gas system in an Audi A3 Sportback g-tron may only be performed by specially trained personnel and at suitable workstations! Country-specific regulations must be observed and the AUDI AG expert training module completed.Maintenance and repairAll service work on the Audi A3 Sportback g-tron must be carried out as specified in ELSA and in the Offboard Diagnosis Information System.4 Natural gasNatural gas is a colourless, odourless and flammable fossil-based gas found in deep underground rock formations. Natural gas forms naturally in much the same way as petroleum. Natural gas is a mixture of various gases, the main ingredient being methane. Natural gas is classified as high-calorific (H-gas or High gas) and low-calorific gas (L-gas or Low gas) based on its methane content. H-gas contains over 87 vol. % methane and L-gas less than 87 vol. % methane. Modern science has now found a way to produce natural gas synthetically. Odorant that is added to natural gas so that it can be detected. This process is referred to as odorization. In gas mode, the Audi A3 Sportback g-tron runs on compressed natural gas or CNG. The vehicle's CNG consumption can vary in practice due to the difference in the quality of H-gas and L-gas.Natural gas qualityThe following table provides a summary of the various natural gas quality levels. The values given are approximations and can vary depending on country of origin and production site.H-gas (North Sea) Calorific value in kWh/m3 Methane (CH4) in vol. % Ethane (C2H6) in vol. % Propane (C3H8) in vol. % Butane (C4H10) vol. % Inert gases in vol. % 11.1 87.1 9.9 3.0H-gas (Russia) 10.0 97.8 1.3 0.9L-Gas (Germany) 8.9 86.8 6.7 6.5Comparison of the physical and technical properties of natural gas and petroleumNatural gas, H-Gas, gaseous Average density in kg/l Calorific value in kWh/kg Delivery required in l/kg RON Ignition temperature in °C 0.155, at a pressure of 200 bar 12.5 6.15, at a pressure of 200 bar 130 approx. 600 Petroleum, liquid 0.75 11.4 1.33 95 approx. 200 – 300One litre of petroleum has the same range as 4.1 litres of CNG. Whereas one litre of petroleum weighs 0.75 kg, 4.1 litres of CNG weigh only 0.64 kg.Outflowing CNG can form a potentially explosive gas-air mixture in the atmosphere. An atmospheric CNG concentration of approx. 4 vol. % to 17 vol. % represents an explosion hazard.5 Audi e-gas projectIn the course of its e-gas project, Audi will develop an entire chain of sustainable energy carriers. The chain begins with electricity produced from renewable energy sources, and has hydrogen and synthetic Audi e-gas as its end products. Construction of an industrial plant to produce synthetic methane (e-gas) from CO2 and renewable electricity has been completed in Werlte (Emsland district of Lower Saxony), Germany. In the first stage of the process, the Audi e-gas plant uses the renewable electricity for electrolysis – splitting water into oxygen and hydrogen (Audi e-hydrogen), which could one day be used to power fuel-cell vehicles. Because there is not yet a widespread infrastructure, there now follows a second process stage in which synthetic renewable methane – Audi e-gas – is produced by the reaction of hydrogen with CO2 in the methanisation plant. It is chemically identical to fossil-based natural gas and can be distributed to CNG filling stations via the natural gas grid. Thanks to this power‑to-gas process, the electricity grid and gas grid are being linked bidirectionally for the first time. Until now while you could generate electricity from gas, the reverse was not possible.Wind power The primary objective of the Audi e-gas project is to promote the use of renewable power. Power grid The wind power is fed into the public power grid.Electrolysis The electrolysis plant uses electricity produced from wind turbines to split water molecules into hydrogen and oxygen.6 Audi e-gas plantThe Audi e-gas plant paves the way for tapping into the natural-gas network with its huge capacity as a storage and transport system for hitherto excess electricity capacity. The CO2 used in the Audi e-gas plant is a waste product from a nearby biogas plant operated by the utility EWE. The CO2, which would otherwise pollute the atmosphere, is bound into the fuel at the Audi e-gas plant. The e-gas plant will annually produce about 1,000 metric tons of e-gas and will bind some 2,800 metric tons of CO2. This corresponds roughly to the amount of CO2 that 224,000 beech trees absorb in a year.Power supplyMethanisation plantGas feed-in into the public gas grid ElectrolysisAmine scrubbing621_002Gas grid The e-gas is stored in the public gas network, thus also enabling households and industry to be supplied with energy from renewable sources.CNG filling station The increasing proportion of e-gas facilitates climate-friendly long-distance mobility. Methanisation The hydrogen reacts with carbon dioxide in a methanisation plant. End product: e-gas (synthetic natural gas).621_0037 Vehicle distinguishing featuresg-tron logo on the boot lid Boot floorCover of CNG tank and bumper without visible exhaustCNG filler neck and petrol filler neck8 g-tron logo on the selector lever and on the dash panelg-tron logo on the dash panel insert and on the CNG fuel gauge621_019g-tron logo on the wingsg-tron logo on the design cover in the engine bay9 Engine mechanicals1.4l TFSI engine of the EA211 series (81 kW)The elevated combustion pressure and combustion temperatures in the engine during gas operation put more stress on the engine. Moreover, the gas does not have the lubricating and damping properties of the petrol additives which protect the engine against mechanical overload at high rpm. Therefore, the following mechanical components of the engine block have been modified: • • • • Valve seat rings Intake/exhaust valves Piston rings CamshaftsThe following add-on engine parts have also been adapted: • • • • Spark plugs Turbocharger Intake manifold Catalytic converter621_065Valves, valve guide and valve seat rings The following modifications were made on the intake end for gas operation: • Nitride-hardened valves • Valve guide is made from a more highly wear resistant material • Valve seat ring is made from a more highly wear resistant material The following modifications were made on the exhaust end for gas operation: • Nitride-hardened valves • Valve seat ring is made from a more highly wear resistant material Piston rings The upper piston rings are PVD (Physical Vapour Deposition) coated to protect them against wear during gas operation.Turbocharger The exhaust gases flow more slowly during gas operation. This would normally cause the compressor impeller to spool up more slowly at low rpm. To avoid turbo lag, therefore, a smaller compressor turbine is used. The (exhaust) turbine wheel has the same diameter as that of the 90 kW 1.4l TFSI engine.Intake manifold Mountings were added to the intake manifold for the gas injector valves.Catalytic converters In terms of their basic design, the exhaust gas aftertreatment systems for petrol and CNG engines are similar. However, when running a vehicle on CNG (CH4) a higher temperature is required to convert the unburnt hydrocarbons. This can only be achieved by increasing the precious metal load in the catalytic converter by a factor of 2 – 2.5. The catalytically active surface area of both catalytic converters is large enough to fully convert the hydrocarbons (CH4) in the exhaust gas at maximum exhaust gas flow (full throttle). What is meant by "conversion" is that the unburnt hydrocarbons contained in the exhaust gas are chiefly converted in the catalytic converter to CO2 and H2O when they react with the catalytic layer in the presence of oxygen.Camshafts To reduce valve seating velocity, the descending cam lobes have a flatter design.Spark plugs The emissions stemming from CNG combustion are more aggressive than those stemming from petrol combustion. Therefore, the spark plug housing and the screw-in thread require a different type of coating.Reference For further information about the function and design of the basic engine, refer to Self Study Programme 616 "Audi 1.2l and 1.4l TFSI engines of the EA211 series".10 Comparison of torque/power curvesEngine code CMBA (basic engine) Power in kW Torque in Nm Engine with engine code CPWA (CNG engine) Power in kW Torque in NmEngine speed [rpm]621_005Engine speed [rpm]621_006Engine code Type Displacement in cm3 Power output in kW (hp) at rpm Torque in Nm at rpm Number of valves per cylinder Firing order Bore in mm Stroke in mm Compression ratio Engine management system Fuel Exhaust emission standards Vehicle useCMBA (basic engine) Four-cylinder in-line engine 1395 90 (122) at 5000 - 6000 200 at 1400 - 4000 4 1–3–4–2 74.5 80 10 : 1 Bosch MED 17.5.21 Premium unleaded 95 RON EU 5 plus A3 '13CPWA (CNG engine) Four-cylinder in-line engine 1395 81 (110) at 4800 – 6000 200 at 1500 - 3500 4 1–3–4–2 74.5 80 10 : 1 Bosch MED 17.5.21 Compressed natural gas (CNG) and premium unleaded petrol (95 RON) EU 5 plus A3 Sportback g-tron11 CNG driveOverviewIn the Audi A3 Sportback g-tron, CNG mode is the priority drive mode. This means that the engine always starts and runs in CNG mode, provided that all the requirments for CNG operation have been met. The driver can switch back and forth between both operating modes.Low-pressure CNG line Plastic lines (petrol) High-pressure CNG lineGas pressure regulator with tank pressure sensor G400 and high-pressure valve for gas operation N372Decoupling elementUnderbody catalytic converter!12Note The pressure in the high-pressure CNG line must be relieved before carrying out work on the CNG system. The instructions given in ELSA and in the Offboard Diagnosis Information System must always be followed by service personnel. Petrol tank filler neck CNG filler neckDistributor with non-return valveCNG tank621_064Guard plateTensioning strapPlastic coverSilencerFuel tank (petrol)Exhaust tailpipe in front of rear axle!Note Even if the engine has changed over from CNG mode to petrol operation because the CNG has run out, a residual amount of CNG still remains in the CNG tanks.13 CNG filler neckThe CNG and petrol tank filler necks are located on the right-hand side of the vehicle under the fuel filler flap.Petrol tank filler neck CNG filler neck621_018Non-return valve with filterA non-return valve with filter is integrated in the CNG filler neck. When the tank is filled, the non-return valve is opened against the force of the spring by the inflowing gas. The gas flows into both CNG tanks at a pressure of up to 260 bar. Any coarse particles in the CNG are removed by the filters. Once filling has been completed, the gas pressure is identical before and after the non-return valve. The non-return valve is now closed again by the spring.SpringNon-return valve open Inflowing CNG621_021621_022Filter To distributorNon-return valve closedThe filter in the CNG filler neck is cleaned by the reduction in pressure which takes place when the filler coupling is removed from the CNG filling system. This means that the filter is maintenance free. It must also be ensured that the ring seal in the CNG filler neck is still in its correct position.621_023e-media Animation showing the gas filler neck.Seal ring14 CNG linesAll CNG lines on the high-pressure side are made from stainless steel and have an outer diameter of 6 mm.Double-clamp ring fittingThe CNG lines are connected to other components by means of a double-clamp ring fitting. When the union nut is tightened, the rear clamp ring is pushed under the front clamp ring and thus provides additional sealing. This type of fitting ensures that the tank is gas impermeable.Loose double-clamp ring fittingTightened double-clamp ring fittingRear clamp ringRear clamp ring621_024621_025Stainless steel pipeUnion nutFront clamp ringUnion nutFront clamp ringDistributor with non-return valveThe distributor with non-return valve serves as a central gas distributor unit. Two high-pressure CNG lines branch from here to the CNG tanks - one to the gas pressure regulator and one to the CNG filler neck. The non-return valve is built into the connection for the CNG line from the CNG filler neck. After refuelling has been completed, therefore, two non-return valves seal off the gas system.Distributor with non-return valve621_026To CNG tankTo CNG tankTo gas pressure regulatore-media Animation showing the distributor.Non-return valveFrom CNG filler neck621_027 15 CNG tankThe Audi A3 Sportback g-tron is equipped with two identical CNG tanks in addition to the petrol tank. Both CNG tanks are securely attached to a rack by means of tensioning straps. This rack is, in turn, bolted to the car body. Plastic CNG tanks are used on the Audi A3 Sportback g-tron. Each individual fuel tank weighs approx. 16 kg and therefore is approx. 27 kg lighter than an equivalent steel CNG tank. The CNG tank has a capacity of approx. 46 litres. This corresponds to a weight of approx. 7.2 kg at a filling pressure of 200 bar and a temperature of 15 °C.621_028Plastic coverGuard plateTensioning strapCNG tankTank shut-off valveProtective rubber stripWhen filling and draining the tank, however, the diameter of the CNG tank can vary by up to 2 mm during operation due to temperature fluctuation. To protect the CNG tanks from damage due to expansion and contraction, it is necessary to place a protective rubber strip between the CNG tanks, the tensioning straps and the rack.Tensioning strap Protective rubber strip621_02916!Note The instructions given in ELSA and in the Offboard Diagnosis Information System must always be followed by service personnel when carrying out work on the CNG system. CNG tankThe CNG tanks on the Audi A3 Sportback g-tron are made from a plastic matrix. The inner layer consists of gas-impermeable polyamide polymer, while a second layer of carbon fiber-reinforced polymer (CFRP) gives the tank strength. The outer layer of glass fiber-reinforced polymer (GFRP) provides robustness and protects the tank against damage. A high-strength epoxy resin serves as a binder for the fibre-based materials.621_030Inner layer: Gas-impermeable poylamideMiddle layer: Carbon fibre-reinforced polymer (CFRP)Outer layer: Glass fibre-reinforced polymer (GFRP)Distributor with non-return valveTank shut-off valve17 Infomation displayed on the CNG tank621_031Key: Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Marking (definition) User only manufacturer-approved pressure relief device ECE Type approval number: E13 110 R-000241 Month/Year of approval: 12 / 2012 Date of first pressure test: 07 / 2013 Working temperature: TS -40 °C / 65 °C Working pressure: 20 MPa/15 °C (20 MPa at a temperature of 15 °C) ID number: AH_314_HY_1c Filling information: CNG ONLY CNG Type 4 (fully fibre-reinforced pressure vessel with plastic liner) Serial number: 0000820/13 Test pressure: 30 MPa Volume: 46 litres Empty weight: 14.50 kg without tank shut-off valve Maximum tightening torque for tank shut-off valve: 130 Nm Do not use after: 07 / 2033 (service life of CNG tank)18 Tank shut-off valvesEach CNG tank is fitted with a tank shut-off valve which is bolted into the CNG tank. The tank shut-off valves are so-called safety valves.Electrical tank shut-off valve Manual tank shut-offThe tank shut-off valve comprises the following components: • • • • • Electrical tank shut-off valve Manual tank shut-off device Thermal cut-out Flow control Connections for CNG lineThermal cut-out Connection for CNG line Electrical connection621_032Manual tank shut-offConnection for CNG tank with flow limiterElectrical tank shut-off valve621_033Thermal cut-outConnection for CNG lineElectrical connection19 Tank shut-off valves 1 and 2 N361 and N362Each of the two tank shut-off valves has an electrically actuated valve. These are tank shut-off valves 1 and 2 N361 and N362. In the de-energised state, the valve spring pushes against the valve seat and thereby seals it, shutting off the gas flow from the CNG tank.621_034Tank shut-off valve 1 N361 or tank shut-off valve 2 N362When the magnetic coil of the valve is energised, the valve opens against the pressure of the valve spring and CNG operation is again possible. At the same time, tank shut-off valves 1 and 2 N361 and N362 receive voltage from the relay gas shut-off valves J908. Relay J908 is, in turn, controlled by control unit J623.621_035ValveValve springMagnetic fielde-media Animation showing the tank shut-off valve in operation20 Filling the tankWhen the vehicle is refuelled, the inflowing CNG exerts up to approx. 260 bar of pressure on the valve springs of the valve seat. The CNG is now able to flow into the CNG tank. Once refuelling has been completed, the inflowing CNG comes to a standstill. The valve spring now pushes the valve against the valve seat again, thereby closing the valve.e-media Animation showing the refuelling process.621_036Inflowing CNG compressed up to 260 barOpen valveValve springManual tank shut-off deviceThe anual tank shut-off device allows the tank shut-off valves to close mechanically. It is possible to run the vehicle on CNG as long as the tank shut-off valves are manually closed. Please note in particular: The manual tank shut-off device does not seal off the channel to the thermal cut-out. When the thermal cut-out is activated, the CNG flows freely out of the CNG tank. This prevents the CNG tank from bursting under exposure to intense heat despite the fact that the tank shut-off valve is closed.621_037Manual tank shut-off deviceManual tank shut-off valve closedChannel to eletrtical tank shut-off valve closed Channel to thermal cut-outThermal cut-oute-media Animation showing the manual tank shutoff device.621_03821 Thermal cut-outThe thermal cut-out is a key component of the tank shut-off valves.The channel to atmosphere is closed by a metal body with fusible link.621_039Fusible linkChannel leading to atmosphere closedIf the thermal cut-out is heated at a temperature above 110 °C for a defined period of time, the fusible link begins to melt and the channel opens. The CNG from the CNG tank can only escape to atmosphere at a reduced rate. The thermal cut-out prevents the CNG tank from bursting under exposure to intense heat.621_062Channel leading to atmosphere opene-media Animation showing the thermal cut-out.22 Flow controlFlow rate is computed by a mechanical safety function of the tank shut-off valves. The connecting flange for the CNG tank houses an additional valve: the flow limiter valve.621_040Connecting flange for CNG tankFlow limiterThe task of a flow limiter is to prevent uncontrolled discharge of CNG from the CNG tank in the event of a sudden loss of pressure on the high-pressure side. A sudden loss of pressure can, for instance, occur due to rupturing of the CNG line.621_041The CNG pressure is identical upstream and downstream of the flow limiter. The valve spring holds the valve in the open position. If a sudden loss of pressure occurs on the high-pressure side and the CNG pressure upstream of the flow limiter is approx. 6.5 bar higher than the pressure downstream of the flow limiter, the valve will be closed due to the pressure difference. Because the flow limiter is legally required to have a degree of leakage, the CNG can only escape from the CNG tank at a greatly reduced pressure. After the manual tank shut-off device closes, pressure equalisation can take place before and after the flow limiter due to the leakage. As a result, the flow limiter automatically opens again.621_042Sealing facee-media Animation showing the flow limiter.621_043Sealing cone with leakage port23 Gas pressure regulatorThe gas pressure regulator is located in the engine bay at the front right and has the task of reducing the pressure of the CNG from approx. 200 bar to 5 – 9 bar according to requirements.e-media Animation showing the gas pressure regulator.621_044Gas pressure regulatorThe gas pressure regulator consists of the following components: • • • • Mechanical gas pressure regulator High-pressure valve for gas operation N372 Mechanical pressure relief valve Tank pressure sensor G400 • High-pressure CNG connection • Low-pressure CNG connection • Coolant connectionsLow-pressure CNG connectionCoolant connectionsTank pressure sensor G400High-pressure CNG connectionMechanical pressure relief valveHigh-pressure valve for gas operation N372621_045The figure is shown rotated for better viewing.24 Mechanical pressure regulatorHigh-pressure valve for gas operation N372 Mechanical pressure regulator621_020The figure is shown rotated for better viewing.In the first stage of the process, the mechanical pressure regulator reduces the pressure of the CNG to approx. 20 bar. The CNG released from the CNG tanks flows through the highpressure connection and into the mechanical gas regulator. In the rest state, the piston spring lifts the hollow-drilled piston off the seal. The CNG flows through the hollow piston to the piston crown side.621_046Inflowing CNGHigh pressure zoneIf no CNG is burnt by the engine, the pressure acting on the piston crown rises to over 20 bar. The pressure of the CNG now displaces the piston against the force of the piston spring until the piston is seated on the seal and the channel is shut off. The CNG no longer flows to the piston crown side.621_047CNG pressure over 20 barIf the vehicle engine is running in CNG mode, the CNG pressure acting on the piston crown decreases. The piston spring lifts the piston off the seal. The CNG again flows through the channel to the piston crown side. During vehicle operation, a gap will occur between the piston and the seal, thereby setting the pressure on the piston crown side to approx. 20 bar.621_048CNG pressure over approx. 20 bar25 High-pressure valve for gas operation N372In the second stage of the process, the high-pressure valve for gas operation N372 reduces the CNG pressure electronically from approx. 20 bar to 5 – 9 bar according to requirements. The reduced CNG pressure of approx. 20 bar is applied to the ball valve of the high-pressure valve for gas operation N372. If the high-pressure valve for gas operation N372 is not activated by the engine control unit J623, the ball valve is closed.621_049Transition from reduction stage 1, approx. 20 bar Valve ball seat Valve ball Low pressure zoneIn CNG mode, the engine control unit J623 activates the highpressure valve for gas operation N372 by means of a pulse-widthmodulated signal. The valve stem together with the metal core are lifted by the magnetic coil. The ball valve opens to create a gap. The CNG flows to the low-pressure side and still has a pressure of between 5 and 9 bar. Pulse-width-modulated activation enables the engine control unit J623 to adapt the CNG pressure on the low-pressure side according to requirements.621_050Valve ballInflowing CNG26 Mechanical pressure relief valveThe mechanical pressure relief valve located on the low-pressure side in the gas pressure regulator is another safety component of the CNG system. If the CNG pressure on the low-pressure side exceeds approx. 16 bar, the pressure relief valve will open. This prevents CNG from flowing to the low-pressure side under excessively high pressure and potentially causing damage. The lack of a sealing cap in the gas pressure regulator may indicate that the pressure relief valve has been activated.Low-pressure CNG connectionMechanical pressure relief valveThe figure is shown rotated for better viewing.621_051Coolant connectionsReducing the CNG pressure produces cold. At very low ambient temperatures, therefore, the temperature in the gas pressure regulator may drop too quickly and cause malfunctioning. To prevent this, the gas pressure regulator is integrated in the cooling system of the internal combustion engine and therefore is heated.Coolant return Coolant flow621_05227 Tank pressure sensor G400The tank pressure sensor G400 is mounted on the gas pressure regulator and measures the actual CNG pressure on the highpressure side during vehicle operation. The tank pressure sensor consists, among other things, of a sensor element and evaluation electronics with electrical connections.621_053The figure is shown rotated for better viewing.The sensor element houses a metal diaphragm, to which four resistors are attached.Electrical connectionSensor element621_054The CNG pressure causes the metal diaphragm to bend. The resistors also undergo a change of shape and resistance.Housing with pressure connectionContact springPCB with evaluation electronicsResistorsMetal diaphragm621_055The evaluation electronics measures the change in resistance and transmits a corresponding voltage signal to the engine control unit J623.Signal output voltage [V]CNG pressure [MPa]28621_056 Gas distributor railInjector rail sensor G401The injector rail sensor G401 is mounted on the gas distributor rail. During vehicle operation, sensor G401 measures the CNG pressure within the injector rail on the low-pressure side. In addition, injector rail sensor G401 measures the temperature of the CNG in the gas distributor rail. Both values are sent to the engine control unit J623 as voltage signals.Injector rail sensor G401621_060Gas injector valves 1 – 4, N366 – N369There are four gas injector valves. Gas injector valve 1 N366, gas injector valve 2 N367, gas injector valve 3 N368 and gas injector valve 4 N369 are integrated in the intake manifold. When the gas injector valves are activated by the engine control unit J623, CNG is injected into the intake manifold upstream of the injectors.Gas distributor rail621_061e-media Animation showing the gas distributor rail.29 Engine management systemSensors and actuatorsSensorsGearbox neutral position sensor G701 Oil pressure switch F22 Oil pressure switch for reduced oil pressure F378Knock sensor 1 G61Accelerator pedal position sensor G79 Accelerator pedal position sensor 2 G185Clutch position sensor G4761) Brake light switch F Brake pedal switch F63Tank pressure sensor G400Injector rail sensor G401Engine speed sensor G28Charge pressure sensor G31 Intake air temperature sensor 2 G299Engine management control unit J623Brake servo pressure sensor G294Intake air temperature sensor G42 Intake manifold pressure sensor G71Fuel pressure sender G247 Low-pressure fuel pressure sender G410 Hall-effect sensor G40 Throttle valve module J338 Throttle actuator position sensors 1+2 for vehicles with electronic accelerator G187, G188Coolant temperature sensor G62 Coolant temperature sensor at radiator outlet G83Oil level/temperature sensor G266 Oxygen sensor G39 Oxygen sensor downstream of catalytic converter G130Wastegate actuator position sensor G581 Auxiliary signals: −− Cruise control system −− Speed signal −− Start request to engine control unit (keyless start 1 + 2) −− Terminal 50 −− Crash signal from airbag control unit30 ActuatorsOil pressure regulating valve N428Fuel pressure regulating valve N276Continued coolant circulation pump V51Oxygen sensor heater Z19 Heater for oxygen sensor 1 downstream of catalytic converter Z29 Ignition coils 1 – 4 with output stage N70, N127, N291, N292Radiator fan control unit J293 Radiator fan V7Injector, cylinders 1 – 4 N30 – N33Camshaft control valve 1 N205 Exhaust camshaft timing adjustment valve 1 N318Activated charcoal canister solenoid valve 1 N80Throttle valve positioner G186 for electronic power controlCharge pressure actuator V465Gas injector valves 1 – 4, N366 – N369Relay for gas shut-off valves J908 Tank shut-off valve 1 N361 Tank shut-off valve 2 N362High-pressure valve for gas operation N372Coolant circuit solenoid valve N492Fuel pump control unit J538 Fuel predelivery pump G6 Fuel gauge sensor GKey: New sensors and actuators compared to the 90 kW 1.4l TFSI engine1)Auxiliary signals: −− Automatic gearbox control unit/engine speed −− ABS control unit/clutch position −− AC compressor621_057only for models equipped with manual gearbox31 Engine management control unit J623The engine control unit J623 can run the internal combustion engine of the Audi A3 Sportback g-tron on both petrol and CNG. If certain framework conditions are met, the engine control unit J623 will run the internal combustion engine on CNG as a priority. In addition to the two CNG tanks, the Audi A3 Sportback g-tron is fitted with a petrol tank which holds approx. 50 litres. Therefore, the Audi A3 Sportback g-tron is a so-called "bivalent" vehicle. Vehicles where the capacity of the fuel tank for the secondary fuel type does not exceed 15 litres are referred to as "quasi-monovalent".621_063Operating strategyIf terminal 15 is "on", tank shut-off valves 1 and 2 N361 and N362 are opened for max. 2 seconds. This ensures a reliable supply of CNG to the gas pressure regulator, while tank pressure sensor G400 determines the fill level of the CNG tank.Engine start without prior filling with CNGCoolant temperature ≤ -10 °C • Engine starts in petrol mode • Engine switches to CNG operation if heating of the injector valves is complete • Engine starts in petrol mode • Engine switches to CNG operation if heating of the injector valves is complete and the oxygen sensor has been activatedCoolant temperature -10 °C • Engine starts in CNG modewith prior filling with CNG• Engine starts in petrol mode • Engine switches to CNG operation if the oxygen sensor has been activated32 Function Adaption of natural gas qualityDescription If the engine control unit J623 determines from information supplied by the tank pressure sensor G400 that the CNG pressure in the CNG tanks has increased by approx. 30 % since the last time the engine was operated, it assumes that the vehicle has been refuelled with CNG. When lambda control is active, natural gas quality is determined for approx. 60 seconds at medium engine speed and load. During this time, the engine control unit J623 determines the injection time adaption necessary to achieve a lambda ratio of 1. The engine will start in petrol mode until adaption of natural gas quality is complete. Reducing the pressure of the CNG in the gas pressure regulator from 200 bar to 5 – 9 bar produces cold. To ensure that the temperature of the CNG does not drop below -50 °C on the exhaust side of the gas pressure regulator, the gas pressure regulator is integrated in the engine's coolant system. Gas injector valves 1 – 4 N366 – N369 will only function properly as of a certain temperature. The engine control unit J623 receives information about the CNG pressure on the highpressure side from the tank pressure sensor G400. It uses this information to detect refuelling of the vehicle with CNG. To enable the fuel level in the CNG tank to be indicated, the engine control unit J623 uses the CNG pressure and the ambient temperature to compute how much gas is stored in the CNG tanks. The engine control unit sends this information to the control unit in the dash panel insert J285 via CAN bus. The injector rail sensor G401 supplies the engine control unit J23 with information about the pressure and temperature of the CNG in the injector rail. The engine control unit uses this information to adapt the CNG injection time. If the CNG pressure in the distributor rail drops 1 bar below the nominal pressure set by the engine control unit, the engine control unit will change over to petrol operation. The opening times of the injector valves are adapted by the engine control unit J623 in a cylinder-selective fashion. Primary influencing factors are: • Engine load • Engine speed • Load demanded by customer • Natural gas quality • CNG temperature on the low-pressure side • CNG pressure on the low-pressure side • Lambda control Other possible influencing factors: • Cooling capacity of air conditioning system • Charging capacity of alternatorCNG temperatureCNG high pressureCNG low pressureInjection timeHeating the injector valves N366 – N369If the coolant temperature is less than or equal to -10 °C, the engine will start and operate in petrol mode. During vehicle operation, gas injector valves 1 – 4 N366 – N369 are subsequently activated by the engine control unit J623. Given that tank shut-off valves 1 and 2 N361 and N362 and the high-pressure valve for gas operation N372 are not activated, CNG can only be injected on the low-pressure side. If the engine control unit J623 determines from the information supplied by the injector rail sensor G401 that the CNG pressure is decreasing, it energises gas injector valves 1 – 4 N366 – N369 continuously for approx. 60 to 90 seconds. This heats up the injector valves and ensures that they function properly. Now the engine control unit J623 is able to switch to CNG operation. If the engine control unit J623 detects a malfunction in CNG mode, it automatically switches to petrol operation. The engine control unit carries out a repeat system test whenever the engine is restarted. The engine control unit J623 does not allow the engine to run in CNG mode as long as the system malfunction is active (static). If the status of the system malfunction changes from active to passive (sporadic), or if the cause of the malfunction has been rectified, CNG operation will again be possible.Diagnostics33 DisplaysInstrument clusterThe dash panel insert on the Audi A3 Sportback g-tron has been adapted for CNG operation. A CNG fuel gauge keeps the driver informed about the current fill level in the CNG tanks. In addition, the driver is informed via the warning lamp for CNG operation that the internal combustion engine is running on CNG. In addition, the driver information system has been upgraded to provide, among other things, information on average fuel consumption, current fuel consumption and remaining range in CNG mode.621_007Indicator lamp for CNG modeFuel gauge for CNGFuel gauge for petrolReference For further information about the displays in the dash panel insert and in the driver information system, refer to the vehicle Owner's Manual.34 ServiceSpecial tools and workshop equipmentVAS 6227 Gas leak detector for CNG powered vehicles V.A.G 1274B/12 Adapter for cooling system tester621_009 621_008T10349 Magnetic release toolT50026 Hand wheel621_010621_011T50025 Wrench621_012!Note Information on the correct use of special tools and workshop equipment can be found in ELSA.35 T10521 Insert tool, 17 mmT10522 Insert tool, 22 mm621_013621_015T40173/2 AdapterT40173/3 Padding621_014621_016T10523 Tensioning strap621_017!36Note For further and up-to-date information on the special tools and workshop equipment, refer to the Workshop Equipment catalogue. AnnexTest your knowledge1. Where is the Audi e-gas plant located?□ □ □ □a) Ingolstadt. b) Werlte. c) Wolfsburg. d) Neckarsulm.2. How do you identify an Audi A3 Sportback g-tron?□ □ □ □a) By the g-tron headlights. a) By the g-tron rims. c) By the g-tron logo on the seats. d) By the CNG filler neck.3. Who is authorised to carry out work on the CNG system in an Audi A3 Sportback g-tron?□ □ □ □a) Only personnel who have received instruction. b) Only personnel who have received training. c) Anyone. d) Only the dealership.4. How many CNG tanks are there on an Audi A3 Sportback g-tron?□ □ □ □a) 4. b) 3. c) 2. d) 1.5. Where is the gas pressure regulator located?□ □ □ □a) In the engine bay at the rear left. b) In the engine bay at the front left. c) In the engine bay at the rear right. d) In the engine bay at the front right.37 6. For up to how long (in seconds) are injector valves N366 – N369 heated?□ □ □ □a) 30. b) 60. c) 90. d) 120.7. How much power does the engine in the Audi A3 Sportback g-tron develop in CNG mode?□ □ □ □a) 60 kW. b) 81 kW. c) 90 kW. d) 122 kW.8. What is the capacity of the CNG tanks?□ □ □ □a) Approx. 7.2 kg. b) Approx. 14.4 kg. c) Approx. 16.0 kg. d) Approx. 27.0 kg.9. What is the task of the "protective rubber strips"?□ □ □ □a) To protect the CNG tank from damage. b) None. c) To protect the CNG tank from vibration. d) To prevent expansion of the CNG tank.10. At what pressure is the CNG tank refuelled?□ □ □ □a) 5 bar. b) 9 bar. c) 200 bar. d) 260 bar.38Test solutions: 1 b; 2 d; 3 b; 4 c; 5 d; 6 c; 7 b; 8 b; 9 a; 10 d Self Study ProgrammesFor further information, please refer to the following Self Study Programmes.SSP 609 Audi A3 ’13Order number: A12.5S00.93.20SSP 610 Audi A3 ’13 Onboard Power Supply and Networking Information on • Networking • Control unitsOrder number: A12.5S00.94.20SSP 616 Audi 1.2l and 1.4l TFSI engines of the EA211 model series Information on the 1.4l TFSI engine • Engine mechanicals • Fuel system • Engine management systemOrder number: A12.5S01.00.20Information on QR codesThis SSP has been enhanced by electronic media (animations, videos and mini-WBTs) for more effective illustration of the content. The references on the pages to the e-media are hidden in QR codes, which are two-dimensional pixel patterns. You can scan those codes using a tablet or smartphone running the appropriate app, which will decipher the hidden web address. To follow the link you require an internet connection. To read the QR codes, you need to obtain a QR scanner from the Apple® or Google® app store and install it on your mobile device. For some media, other players may be required in some cases. On PCs and notebooks, the e-media can be selected in the SSP PDF and then retrieved online after logging into GTO. All e-media are managed on the Group Training Online (GTO) platform. You require a user account for GTO and have to log in after scanning the QR code before you can retrieve the media. On an iPhone, iPad and many Android devices, you can store your login credentials in the mobile browser. That simplifies logging in the next time. Make sure you protect your mobile device against unauthorised use by setting a PIN. Please note that using the e-media over the mobile phone network may incur considerable charges, especially if using data roaming tariffs abroad. This is your responsibility alone. The best option is to use a WiFi connection. Apple® is a registered trademark of Apple® Inc. Google® is a registered trademark of Google® Inc.39 Audi Vorsprung durch TechnikAll rights reserved. Technical specifications are subject to change. Copyright AUDI AG I/VK-35 service.training@audi.de AUDI AG D-85045 Ingolstadt Technical status 10/13 Printed in Germany A13.5S01.05.20621