TECHNICAL DOCUMENTATION
SSP 622 Second generation Audi clean diesel

This PDF is currently unavailable.
Read document text
Self Study Programme 622 For internal use onlySecond generation Audi clean dieselAudi Service TrainingThe SCR system - the key to achieving the tougher EU 6-1 (W), BIN 5, Tier 2 and LEV III emission standards Reducing the nitrous oxide content (NOx) in exhaust emissions is a global challenge facing automobile manufacturers, who are required to meet the new statutory limits set by the Euro 6 standard and equivalent international regulations on exhaust emission limits. A modern "Selective Catalytic Reduction" (SCR) emission control system utilises the chemical synthesis product of urea (AdBlue®) to reduce NOx emissions. In SCR systems, AdBlue® reacts with the NOx emissions to produce water vapour and nitrogen. NOx is short for nitrous oxide gases; they occur during the combustion process in diesel engines and are reduced by means of SCR technology. '' AdBlue® is manufactured by a solution of a chemical called urea (also called carbamide) in water. Urea is a synthetic product which usually is made from natural gas and used in fertilizers, plastics and cosmetics. AdBlue® is not made from recycled agricultural products. For exhaust gas aftertreatment in the AdBlue® SCR system, the exhaust system requires additional components such as the heated catalyst1), the water-cooled metering valve, the diesel particulate filter with integrated DeNOx catalytic converter and the ammonia blocking catalytic converter. AdBlue® is a registered trademark of Verband der Automobilindustrie (VDA).1)Installed in a limited number of models only.622_023622_002Learning objectives of this self study programme: This Self Study Programme describes the design and function of an exhaust gas aftertreatment system adapted for the use of AdBlue® reducing agent. Once you have completed this Self Study Programme you will be able to answer the following questions: • What is the function of the heated catalyst? • Which new sensors are integrated in the reduction system? • Why does the exhaust gas temperature have to be relatively high? • What is the function of the ammonia blocking catalytic converter?2ContentsIntroductionEmission standard ___________________________________________________________________________________________________________________________________________ 4 Audi models based on the Modular Longitudinal Matrix (MLB) with SCR system _____________________________________________________________________ 5Exhaust gas aftertreatment by an SCR systemBasic design (overall system) _______________________________________________________________________________________________________________________________ 6Exhaust systemsIntroduction __________________________________________________________________________________________________________________________________________________ 8 1.6l / 2.0l TDI engine (EA288) _ ____________________________________________________________________________________________________________________________ 8 3.0l V6 TDI engine __________________________________________________________________________________________________________________________________________ 12 4.2l V8 TDI engine _ _________________________________________________________________________________________________________________________________________ 16Fuel and reducing agent tankReducing agent tank ________________________________________________________________________________________________________________________________________ 18 Audi Q7 _ ______________________________________________________________________________________________________________________________________________________ 18 Audi A6 ’11 and Audi A7 Sportback _______________________________________________________________________________________________________________________ 20 Audi A4 ’14 __________________________________________________________________________________________________________________________________________________ 22 Audi A8 ’10 and Audi A8 ’14 _______________________________________________________________________________________________________________________________ 24 Swirlpot in active tank ______________________________________________________________________________________________________________________________________ 27Sensors and actuatorsSystem overview (shown using the 3.0l V6 TDI engine as an example) _______________________________________________________________________________ 28 Reducing agent pump V437 _______________________________________________________________________________________________________________________________ 30 Reducing agent tank sender G684 (level sender) _ _______________________________________________________________________________________________________ 31 Particulate sensor G784 with control unit _______________________________________________________________________________________________________________ 32 Reducing agent injector N474 (metering valve) _________________________________________________________________________________________________________ 32Display strategyOverview _____________________________________________________________________________________________________________________________________________________ 35 Messages relating to reducing agent fill level ___________________________________________________________________________________________________________ 36 Fault warnings _ ______________________________________________________________________________________________________________________________________________ 37ServiceTools __________________________________________________________________________________________________________________________________________________________ 38AnnexSelf Study Programmes ____________________________________________________________________________________________________________________________________ 39The Self Study Programme teaches a basic knowledge of the design and functions of new models, new automotive components or new technologies. It is not a Repair Manual! Figures are given for explanatory purposes only and refer to the data valid at the time of preparation of the SSP. This content is not updated. For further information on maintenance and repair work, always refer to the current technical literature.NoteReference3IntroductionEmission standardThe emission standard for motor vehicles limits sets out limits for carbon monoxide (CO), nitrous oxide (NOx), hydrocarbons (HC) and particulate matter (PM) and subdivides vehicles thus into emission classes. Specific key numbers are assigned and used, for instance, to calculate road tax and to classify vehicles for low emission zones. Emission limits vary according to engine type (petrol or diesel engine) and vehicle type. They are subject to ongoing tightening within the European region. The values are measured in type tests within the driving cycle, and the vehicle manufacturer has to guarantee the compliance with these limits for a specified period of time and mileage. This is achieved by in-service monitoring and by carrying out recalls in case of systematic faults. Some vehicles are subject to limits on evaporative fuel emissions and mandatory On-Board Diagnostics (OBD).Emission limits from the emission standardsEuropean Union Particulate matter (PM)USAJapanin %Hydrocarbons (HC) and nitrous oxides (NOx)Nitrous oxides (NOx)Nitrous oxides (NOx)in %in % Carbon monoxide (CO)Limits in g/kmLimits in g/miLimits in g/mi622_003Abbreviations LEV ULEV SULEV BIN 5 4Low Emission Vehicle Ultra Low Emission Vehicle Super Ultra Low Emission Vehicle Emission standard for California and other US statesThe term "BIN" stems from the word "bag"; this is because the exhaust gases are collected in bags during emission tests and analysed. There are 10 categories ranging from BIN 10 (highest emissions) to BIN 1 (lowest emisisons).Phase-in dates of EU emission standards for diesel engines EU 5 A New types from to New vehicles from to Emission limits OBD standard EU 5 F EU 5 J EU 6 N EU 6 Q – – – EU 6 T – – – EU 6 W EU 6 ZA1)01.09.2009 01.09.2011 01.09.2011 – 31.08.2011 31.08.2014 31.08.2014 – 01.01.2011 01.01.2013 01.01.2014 –01.09.2014 01.09.2017 31.08.2017 – 01.09.2015 01.09.201831.12.2012 31.12.2013 31.05.2015 31.12.2012 31.12.2013 31.08.2015 31.08.2018 – EU 5 a EU 5 EU 5 b EU 5 EU 5 b EU 5 + EU 6 a EU 6 EU 6 b EU 6 EU 6 b EU 6 + EU 6 b EU 6-1 EU 6 c EU 6-21)at planning stageAudi models based on the Modular Longitudinal Matrix (MLB) with SCR system622_014A4 ’14 A5 ’14 Engine type SCR tank system manufacturer Reducing agent active tank Reducing agent passive tank AdBlue® capacity 2.0l R4 TDI 3.0l V6 TDI Inergy Gen. II x x 20 litresQ5 2.0l R4 TDI 3.0l V6 TDI Inergy Gen. II Inergy Gen. I xA6 ’14 A7 Sportback 2.0l R4 TDI 3.0l V6 TDI Inergy Gen. II xQ7 3.0l V6 MPI Inergy Gen. I x xA8 ’13 3.0l V6 MPI 4.2l V8 TDI Inergy Gen. II xA8 ’14 3.0l V6 MPI 4.2l V8 TDI Inergy Gen. II Röchling x x22 litres17 litres23 litres20 litres27 litresReference For information on the design and function of the SCR system in the Audi A3 saloon (USA), refer to Self Study Programme 625 "Audi A3 saloon".5Exhaust gas aftertreatment by an SCR systemBasic design (overall system)Exhaust gas temperature sender 2 (upstream of oxidising catalytic converter) G448Oxygen sensor G39Reducing agent injector N474 (water cooled)Engine control unit J623Oxidising catalytic converter with catalyst heater1)SCR-coated diesel particulate filterNOx sender 2 with control unit G687Ammonia blocking catalytic converterCatalyst heater control unit 11) J1021ComponentsThe exhaust gas aftertreatment system comprises the reducing agent tank system together with the water-cooled reducing agent injector, a close-coupled heated catalyst1), an SCR-coated diesel particulate filter and an ammonia blocking catalytic converter located upstream of the main silencers. Multiple temperature sensors are integrated in the exhaust system upstream and downstream of the turbocharger together with the oxidising catalytic converter, the diesel particulate filter, the oxygen sensor and the NOx sender. The exhaust aftertreatment process is monitored with the aid of the various sensors.1)Installed in a limited number of models only.6Task of the SCR systemIn the first stage, emissions and fuel consumption are reduced by minimising friction; in the second stage, emissions are minimised by the exhaust gas aftertreatment system. To achieve the EU 6 emission limits, new components, sensors and actuators are used to minimise nitrous oxide emissions in addition to the familiar AdBlue® reducing agent.Reducing agent filler neckReducing agent metering system control unit J880Heater metering lineSwirlpot with reducing agent pump V437Reducing agent transfer pump V436Reducing agent active tankReducing agent passive tank622_0257Exhaust systemsIntroductionTo meet the requisite emission standards, modern exhaust systems are no longer configured simply as silenced exhaust systems, but as exhaust gas treatment and monitoring systems. They comprise: • Oxidising catalytic converter with/without catalyst heater1) • SCR-coated diesel particulate filter • Ammonia blocking catalytic converter The complex open and closed-loop control functions have been integrated into the engine control unit.1)The exhaust systems has the following sensors: • Oxygen sensors • NOx sensors • Differential pressure sensors In addition, there are several temperature sensors which monitor the temperature levels in the exhaust system.Installed in a limited number of models only.1.6l / 2.0l TDI engine (EA288)Exhaust gas temperature sender 4 (downstream of diesel particulate filter) G648 Flexible pipeAmmonia blocking catalytic converter, see "Ammonia blocking catalytic converter" on page 11Exhaust gas treatment module, see "Exhaust gas treatment module with SCR system" on page 10Engine modifications To meet the EU 6 requirements, the existing 2.0l and 1.6l TDI engines have been upgraded to include the following components: • • • • Variable valve timing High pressure exhaust recirculation Cylinder pressure control system 2000 bar injection systemExhaust flap control unit J883622_006Reference The design and function of engines from the Modular Diesel System (EA288) are explained in Self Study Programme 608 "Audi 1.6l / 2.0l 4-cylinder TDI engines".8Exhaust gas treatment moduleTo achieve the EU 6 emission limits, an NOx aftertreatment system will be integrated into the close-coupled exhaust gas treatment module from the EU 5 engine together with the oxidising catalytic converter and the coated particulate filter. Achieving the EU 6 emission limits requires the use of a Selective Catalytic Reduction (SCR) system.Versions Depending on model version, a distinction will be made in future between two EU 6 variants of the close-coupled exhaust gas treatment module: • System with NOx accumulator catalyst (NSK) for smaller and lighter vehicles based on the Modular Transverse Matrix (MQB) • System with Selective Catalytic Reduction (SCR) for vehicles based on the Modular Longitudinal Matrix (MLB) with a larger flywheel mass (EU 6 heavy duty)OverviewExhaust gas recirculation servomotor 2 V339EGR valveEGR coolerExhaust gas treatment module Turbocharger622_0289Exhaust gas treatment module with SCR systemThe substrate of the close-coupled exhaust gas treatment module is made of metal, enabling the module to reach its operating termperature more quickly. This metal body is coated with a substrate of metal oxides, e.g. aluminium oxide, with additional layers of platinum and palladium. These precious metals act as catalysts for hydrocarbons and carbon monoxide. Integrating the SCR coating into the particulate filter using copper zeolite enables the system to be positioned close to the engine. After cold-starting the engine, the operating temperature of the SCR catalyst is reached more quickly and maintained for longer during low-load vehicle operation. Additional engine modifications are required for heating the catalytic converter. The reducing agent injector N474 is integrated directly downstream of the oxidising catalytic converter and above the transition funnel, with the result that the entire volume in the funnel is available for carburetion. Since air cooling is no longer sufficient due to the high thermal load, the reducing agent injector has a coolant jacket which, in addition to the valve, protects the electrical connection against overheating. The reducing agent injector is integrated in the low-temperature circuit of the engine cooling system, see page 34.DesignReducing agent injector N474 (water cooled)Exhaust gas temperature sender 2 G448Oxygen sensor G39Exhaust gas temperature sender 3 G495NOx sender G295TurbochargerMixerOxidising catalytic converter Exhaust gas temperature sender 1 G235 Differential pressure sender G505Connection for exhaust gas pressure sensor 1 G450SCR-coated diesel particulate filter622_022 10Ammonia blocking catalytic converterAn ammonia blocking catalytic converter with a combined SCR and oxidising catalyst coating is located downstream of the SCR-coated diesel particulate filter and performs two tasks: Its first task is to oxidise the carbon monoxide (CO) produced during soot regeneration to carbon dioxide (CO2) through reaction with the precious metal-containing coating. Its second task is to ensure that no NH3 leaves the exhaust system. During this process, NH3 is oxidised to N2 and H2O.Design and sensorsExhaust pipe from exhaust gas treatment moduleAmmonia blocking catalytic converterExhaust flap control unit J883622_021Exhaust valve control unit J883 The task of the control unit is to generate a slight backpressure downstream of the diesel particulate filter by means of a motorised exhaust gas flap. This produces an excess pressure of approx. 30 – 40 mbar downstream of the particulate filter relative to the exhaust pressure downstream of the exhaust flap. This excess pressure results in a positive flow gradient (purging rate) in the EGR cooler and in the downstream EGR valve. The flow of recirculated exhaust gas is controlled (mapped) by the EGR valve. This backpressure is measured by exhaust gas pressure sensor 1 G450. The 73° operating range of the exhaust flap is defined by: • the exhaust pressure downstream of the exhaust flap • the nominal exhaust pressure upstream of the exhaust flap • the mass flow through the exhaust flap In the event of failure of exhaust gas recirculation servomotor 2 V339, the exhaust valve control unit J883 takes on the task of controlling the exhaust gas recirculation rate.113.0l V6 TDI engineWhat state-of-the-art diesel and direct injection petrol engines have in common are ever-decreasing exhaust gas temperatures. Automatic start-stop systems, regular intermittent operation of compact internal combustion engines, or the more effective conversion of combustion energy to mechanical drive power often result in temperatures below the light-off temperature of the catalytic converter. The exhaust gas treatment module of the 3.0l V6 TDI engine has been modified to meet the EU 6 (W) emission standard. To make use of heat flow, the components of the exhaust gas treatment module have been fitted close to the engine.OverviewExhaust gas temperature sender 2 (upstream of oxidising catalytic converter) G448Oxidising catalytic converterConnection for differential pressure sensor downstream of diesel particulate filter Exhaust gas temperature sender 4 (downstream of diesel particulate filter) G648Oxygen sensor G39 Connection for differential pressure sensor upstream of diesel particulate filter Connection for catalytic converter heater 11) Z119 Reducing agent injector N474 (water cooled) SCR-coated diesel particulate filter, see "Oxidising catalytic converter and diesel particulate filter" on page 141)Installed in a limited number of models only.12Sensors and connections on the diesel particulate filter Exhaust gas temperature sender 2 G448 and exhaust gas tem(upstream of oxidising catalytic converter) perature sender 3 G495 are used, respectively, upstream and G448 Oxygen sensor downstream of the oxidising catalytic converter in order to G39 monitor the operating temperature of the oxidising catalytic converter. The values measured by both exhaust gas temperature sensors are also important variables for the regenConnection for differential pressure sensor downstream of diesel particulate filter eration of the diesel particulate filter. To determine the load on the particulate sensor, the exhaust pressure is measured upstream and downstream of the particulate filter and not against atmospheric pressure. Exhaust gas temperature sender 4 G648 monitors the regeneration temperature.Exhaust gas temperature sender 2Connection for exhaust gas temperature sender 3 (downstream of oxidising catalytic converter) G495Connection for differential pressure sensor upstream of diesel particulate filter622_046NOx sender 2 G687Ammonia blocking catalytic converter, see "Ammonia blocking catalytic converter" on page 15622_00513Oxidising catalytic converter and diesel particulate filterIn some models, an electric heating plate1) has been integrated into the oxidising catalytic converter to enable the oxidation catalyst reach its light-off temperature more quickly. The heated catalyst1) consists of a thin sheet of wound metal substrate, which is installed upstream of the catalytic converter and energised as required. The exhaust gases are additionally heated with 500 watts of power at cold start, after which the heating plate1) is energised at low engine load (partial load) in order to maintain the temperature of the catalytic converter.OverviewOxygen sensor G39 Oxidising catalytic converter Connection for differential pressure sensor downstream of diesel particulate filterExhaust gas temperature sender 2 (upstream of oxidising catalytic converter) G448Reducing agent injector N474 (water cooled)Exhaust gas temperature sender 4 (downstream of diesel particulate filter) G648Mixer Connection for differential pressure sensor upstream of diesel particulate filter Heating plate1)SCR-coated diesel particulate filterConnection for catalytic converter heater 11) Z119Exhaust pipe to ammonia blocking catalytic converter622_0201)Installed in a limited number of models only.14Ammonia blocking catalytic converterAn ammonia blocking catalytic converter is used in place of the previous DeNOx catalytic converter. Now, an ammonia blocking catalytic converter with a combined SCR and oxidation catalyst coating is installed downstream of the SCR-coated diesel particulate filter and performs the following two tasks: First, to oxidise the carbon monoxide (CO) produced during soot regeneration to carbon dioxide (CO2) through reaction with the precious metal-containing coating. The second task of the ammonia blocking catalytic converter is to ensure that no NH3 leaves the exhaust system. During this process, NH3 is oxidised to N2 and H2O.Design and sensorsAmmonia blocking catNOx sender 2 G687622_024154.2l V8 TDI engineIn the large-displacement 4.2l V8 TDI engine, an oxidising catalytic converter with a 500 watts heating plate is fitted in each exhaust pipe. This means that an oxygen sensor and an exhaust gas temperature sensor are installed upstream and downstream, respectively, of the oxidising catalytic converter. Both exhaust pipes subsequently merge into one. To ensure the even distribution of reducing agent via a mixer, the air-cooled metering valve is installed in the most favourable position. The exhaust system then splits again in order to accommodate the two SCR-coated diesel particulate filters. Two exhaust gas temperature sensors located at the outlet of the diesel particulate filter monitor the regeneration temperature.OverviewOxygen sensor G39 Exhaust gas temperature sender 2 (concealed) G448 Heated catalyst Flexible pipe Connection of catalytic converter heater 1 Z119 Exhaust gas temperature sender 3 for cylinder bank 1 G496Oxygen sensor 2 G108 Heated catalyst 2Vorab-GrafikConnection for differential pressure sender G505NOx sender G295Flexible pipe Exhaust gas temperature sender 2 for bank 2 G449 Catalytic converter heater 2 Z120 Exhaust gas temperature sender 3 for bank 2 G497622_019Reducing agent injector N474MixerReducing agent injector N474 (metering valve) and mixerThe metering valve is an air-cooled solenoid valve, and its task is to provide a continuous supply of reducing agent to the SCR-coated diesel particulate filter. The reducing agent injector is activated by the engine control unit in a pulse-width-modulated (PWM) fashion. An even distribution of ammonia in the SCR-coated diesel particulate filter is the key to a high degree of implementation. The so-called mixer is located directly downstream of the reducing agent injector and is responsible for optimally mixing the reducing agent and exhaust gases. The mixer induces turbulence in the exhaust gas stream and in the reducing agent; it also acts as an evaporator, its hot surface causing some of the reducing agent to change from a liquid to a gaseous state.16Rear section of exhaust systemIn the further course of the exhaust system, both pipes merge into a connecting pipe. The combined exhaust gas streams then flow into the two main silencers. The NOx sender 2 G687 is mounted on the connecting pipe housing. This sensor monitors the carbon monoxide (CO) produced during the regeneration cycle and the small quantities of ammonia arising from the high temperature gradients during regeneration of the diesel particulate filter. Both values influence the quantity of reducing agent injected.Catalytic converter heater Z119 and Z120The active heating plate provides a significant reduction in emissions both during the start phase and at low engine load. The heating plate has a power output of 500 watts and is located directly upstream of the main catalytic converter. In SCR systems, the heated catalyst is able to optimally evaporate the injected reducing agent and thereby increases the efficiency of the SCR catalytic converter. These heated metal catalytic converter not only increase the operating temperature by up to 100 °C, but also allow NOx conversion to begin much earlier by injecting the reducing agent onto the heated diesel particulate filter. To keep the catalytic converter warm for as long as possible, the heating plate and the catalytic converter are encased in an insulating layer and a second stainless steel housing.Oxygen sensor G39 Connection of catalytic converter heater 1 Z119 Exhaust gas temperature sender 3 for cylinder bank 1 G496Heating plateSCR-coated diesel particulate filterExhaust gas temperature sender 2 G448Oxidising catalytic converter622_049Exhaust gas temperature sender 4 for bank 1 G651NOx sender 2 G687Exhaust gas temperature sender 4 for bank 2 G649Connecting pipe622_004 17Fuel and reducing agent tankReducing agent tankAn active fuel tank and, depending on model, an auxiliary passive fuel tank serving as a reducing agent reservoir are used in addition to the conventional diesel fuel tank. The pressure relief valve has also been deleted with the integration of the service vent into the diaphragm filler cap. Both tanks, if available, are connected to the filler neck by ventilation lines.Audi Q7Two reducing agent reservoirs, an active tank and a passive tank, have been added to the conventional diesel fuel tank. The capacity of the diesel fuel tank has been kept at 100 litres by making optimal use of available underbody design space. The reducing agent storage capacity of approximately 23 litres is distributed to the reducing agent active tank directly below the filler neck (7.5 litres) and the underbody reducing agent passive tank (15.5 litres). The diesel fuel tank is filled, as is customary, via the tank filler neck. Both filler necks can be accessed via the tank flap.OverviewTransfer line Reducing agent filler neck Reducing agent active tank (7.5 litres)Bleeding/vent line Reducing agent pump V437Diesel fuel tank (100 litres)Reducing agent passive tank (15.5 litres)Bleeding lineFilling line622_011Reference For more detailed information about the function of the reducing agent system in the Audi Q7, please refer to Self-Study Programme 428 "Audi 3.0l V6 TDI engine with ultra low emission system (EU6, LEV II, BIN5)".18Reducing agent active tankThe reducing agent pump V437, the overflow connection for filling the reducing agent passive tank, the connection for filling the reducing agent passive tank, and the heated supply and return lines are mounted on the reducing agent active tank. The reducing agent active tank is heated and has built-in sensors. When the active tank is filled, the reducing agent flows into the reducing agent passive tank under gravity after the preset level in the reducing agent active tank is reached.View from belowSwirl pot Overflow fitting Supply line Return line Reducing agent pump V437Connection to reducing agent injector N474 OverflowThe reducing agent passive tank serves as additional storage capacity, is not heated and does not have any built-in sensors. The reducing agent transfer pump V436 which circulates the reducing agent is mounted on it. The pump is configured as a diaphragm piston pump and activated by the engine control unit by means of analogue signals. The transfer pump V436 is activated by the engine control unit J623 and pumps the reducing agent from the reducing agent passive tank into the reducing agent active tank. The reducing agent transfer pump V436 is activated whenever the reducing agent tank sender G684 in the reducing agent active tank detects a low fill level, and provided that the vehicle is travelling faster than 10 kph. The fuel tank sender may not be at its max. level for short times due to sloshing movement of the reducing agent on winding roads. The engine control unit J623 recognises this condition and likewise activates the reducing agent transfer pump.Connection to passive tank622_017Reducing agent passive tankReducing agent transfer pump V436622_018 19Audi A6 ’11 and Audi A7 SportbackA 17-litre reducing agent tank is used on the underbody in addition to the fuel tank, which holds approx. 73 litres. This reducing agent tank is configured as the active tank. It is filled from the exterior via a filling line located adjacent to the filler neck and is identified by a black filler cap. It is made from high-grade plastic and adapted to the underbody contours by blow moulding.OverviewDiesel / reducing agent filler neckBleeding line622_050Diesel fuel tankFilling line622_010Reducing agent active tank (17 litres)Bleeding line20Reducing agent active tankA compact swirlpot is now mounted on the reducing agent active tank. This swirlpot accommodates the reducing agent pump and built-in sensors for monitoring the reducing agent temperature, reducing agent pressure and fill level, as well as the reducing agent system heater. The reducing agent metering system control unit J880, the connection for the metering line to the water-cooled reducing agent injector, the drain outlet and the electrical connector are arranged on the exterior of the swirlpot.OverviewFilling lineBleeding line622_013Swirlpot with reducing agent pump V437View from belowReducing agent tank heater Z102Connection for heated metering line to reducing agent injector N474 Swirlpot with reducing agent pump V437 Reducing agent drain outlet Reducing agent metering system control unit J880622_013 21Audi A4 ’14Due to space constraints, active and passive reducing agent tanks with a total capacity of 20 litres are used on this model in addition to the fuel tank, which holds approx. 61 litres. These reducing agent tanks are simultaneously filled from the exterior via a split filling line located adjacent to the tank filler neck. The reducing agent filler neck is identified by a black filler cap. Both reducing agent tanks are made from high-grade plastic (PEHD = polyethylene) and optimally adapted to the available underbody design space by means of blow moulding.OverviewReducing agent passive tankReducing agent filler neckReducing agent transfer pump V436Diesel fuel tankView from belowReducing agent active tankSwirlpot with reducing agent pump V437 Reducing agent metering system control unit J880Heated metering line to reducing agent injector N474622_007 22Reducing agent active tankThe filling line connection, the bleeding and vent lines, the drain outlet and the filling line of the transfer pump on the passive tank are located on the exterior of the active reducing agent tank. The reducing agent metering system control unit J880 and the swirlpot are also mounted on it. This swirlpot accommodates the reducing agent pump and built-in sensors for monitoring the reducing agent temperature, reducing agent pressure and fill level, as well as the reducing agent system heater. The connection for the heated metering line to the water-cooled reducing agent injector and the electrical connector are arranged on the exterior of the swirlpot.Transfer pump filling lineBleeding line (heated) Filling line from filler neckReducing agent tank sender G684Reducing agent metering system control unit J880Swirlpot with reducing agent pump V437Heated metering line to reducing agent injector N474622_040Reducing agent passive tankThe reducing agent passive tank serves as additional storage capacity, is not heated and does not have any built-in sensors. The reducing agent transfer pump V436 which circulates the reducing agent is mounted on this tank. It is designed as a diaphragm piston pump and activated by means of analogue signals. The reducing agent transfer pump V436 is activated by the engine control unit J623 via the reducing agent metering system control unit J880. The pump transfers reducing agent from the reducing agent passive tank to the reducing agent active tank. The reducing agent transfer pump V436 is activated whenever the reducing agent tank sender G684 in the reducing agent active tank detects a low fill level, and provided that the vehicle is travelling faster than 10 kph.Bleeding lineFilling lineTransfer line to active tankReducing agent transfer pump V436622_041 23Audi A8 ’10 and Audi A8 ’14Due to space constraints, active and passive reducing agent tanks with a total capacity of 27 litres are used on this model in addition to the fuel tank, which holds approx. 90 litres. Only the active reducing agent tank is filled from the exterior via the filling line located adjacent to the tank filler neck; it is identified by a black filler cap on the A8 ’10 and by a blue filler cap on the A8 ’14 and later models. The reducing agent passive tank in the boot can be filled using filling unit VAS 6542 or the filling bottle (Kruse bottle1)). The fuel tank is made from high-grade plastic (PEHD = polyethylene) and optimally adapted to the available underbody design space by means of blow moulding.1)Use VW and Audi approved reducing agent AdBlue® as specified by the VW and DIN 70070 standards. Original part number: G 052 910 A2 for 0.5 gallon drum, G 052 910 A4 for 10-litre drum.Overview - Audi A8 ’14Reducing agent active tank Reducing agent metering system control unit J880 Transfer line Reducing agent passive tank (on Audi A8 ’14 only)Bleeding lineReducing agent transfer pump V436Reducing agent filler neckFilling lineSwirlpot with reducing agent pump V437Heated metering line to reducing agent injector N474Diesel fuel tank622_00924Reducing agent active tank on Audi A8 ’10This reducing agent tank is configured as the active tank. It has a capacity of 20 litres and is mounted on the rear right side wall in the boot. It is directly filled from the exterior. The swirlpot, including all sensors, the reducing agent pump, the reducing agent heater and the reducing agent metering system control unit, is located on the reducing agent tank.Bleeding line connectionFilling line connection Heated metering line to reducing agent injector N474Reducing agent tank heater Z102Swirlpot with reducing agent pump V437Reducing agent tank sender G684622_042Reducing agent active tank on Audi A8 ’14Due to space-saving constraints, a reducing agent active tank with a reduced capacity of 16 litres is installed in the boot on the rear right. To ensure an adequate supply of reducing agent in between service visits, the reducing agent metering system has an additional 12-litre passive tank. In this case also, the reducing agent active tank is filled from the exterior via the filler neck. The tank accommodates the swirlpot including sensors, the reducing agent pump, the reducing agent heater and the reducing agent metering system control unit. The active tank is filled from the passive tank via a transfer line.Filling line connection Reducing agent metering system control unit J880 Connection for bleeding line reducing agent filler neck Connection for transfer line from transfer pump on passive tankConnection for bleeding line from passive tank Heated metering line to reducing agent injector N474Swirlpot with reducing agent pump V437 Reducing agent tank heater Z102622_026 25Reducing agent active tank on Audi A8 ’14To extend the range of the SCR system, a quasi-reserve tank is installed in the spare wheel well in addition to the active tank. In this case, the passive tank has been adapted to fit the spare wheel well and total reducing agent capacity has been increased by 12 litres. The passive tank does not have any built-in sensors or a reducing agent heater. Reducing agent delivery is dependent on the fill level in the active tank and carried out by a transfer pump on the active tank. The passive tank is not filled via the reducing agent filler neck like the active tank. It has to be filled separately. The passive tank can be filled during the service event using filling unit VAS 6542 or the filler bottle (Kruse bottle).OverviewTransfer line from active tank Bleeding line to reducing agent active tankConnector in bleeding lineReducing agent transfer pump V436Pasisve tank filler neck (not colour coded)622_02726Swirlpot in active tankThe swirlpot is installed in the reducing agent active tank from below and houses the following components: • Reducing agent pump V437 • Reducing agent pressure sender G686 • Reducing agent tank heater with heating mat Z102 • Reducing agent filter • Reducing agent tank sender G684 • Reducing agent temperature sender G685Pumping operation The reducing agent pump (SCR metering pump) is configured as a brushless or electrically commutated three-phase motor. It pumps the reducing agent to the reducing agent injector N474 via an SCR pressure sensor. The pressure sender for the reducing agent metering system G686 measures the outlet pressure of the metering pump to the reducing agent injector within a pressure range from -0.5 bar to approx. 9.0 bar (relative). The reducing agent temperature sender G685 measures the reducing agent temperature within a range from -40 °C to 80 °C.Reducing agent heater As the reducing agent freezes at -11 °C, the reducing agent metering system is equipped with a heater. The swirlpot has an integrated heating mat which heats the swirlpot together with all its internal components (resistance heater). The metering line to the external reducing agent injector N474 is heated by a resistance heater.OverviewReducing agent pump V437 Reducing agent tank heater Z102Thermo mat stripsReducing agent tank sender G684Reducing agent temperature sender G685622_01527Sensors and actuatorsSystem overview (shown using the 3.0l V6 TDI engine as an example)SensorsAir mass meter G70Engine speed sensor G28 Hall-effect sensor G40 Powertrain CAN databus NOx sender 2 G687 Engine management control unit J623 Diagnostic port Private bus Coolant temperature sensor G62Radiator outlet coolant temperature sensor G83 Temperature sender for engine temperature control G694Fuel temperature sender G81 Oil pressure switches 1 + 2 F445, F446Fuel pressure sensor G247 Accelerator pedal position sensor G79 Accelerator pedal position sensor 2 G185 Exhaust gas recirculation potentiometer G212 Brake light switch FBrake servo pressure sensor G294 Charge pressure sensor G31 Intake air temperature sensor G42 Oxygen sensor G39 Reducing agent tank sender G684 Reducing agent pressure sender G686Reducing agent temperature sender G685Exhaust gas temperature sender 3 G495EGR temperature sensor G98 Exhaust gas temperature sender 1 G235 Exhaust gas temperature sender 4 (downstream of diesel particulate filter) G648 Exhaust gas temperature sender 2 (BIN 5 only upstream of cat) G448 Differential pressure sender G505Auxiliary signals: – Cruise control system – Speed signal – Start request to engine control unit (Kessy 1 + 2) − Terminal 50 – Crash signal from airbag control unit28ActuatorsInjectors, cylinders 1 – 3 N30, N31, N32Injectors, cylinders 4 – 6 N33, N83, N84Automatic glow period control unit for J179 Glow plugs 1 – 3 Q10, Q11, Q12 Glow plugs 4 – 6 Q13, Q14, Q15Oil pressure regulating valve N428Throttle valve control unit J338Fuel metering valve N290Fuel pressure regulating valve N276Thermostat for mapped engine cooling F265 Exhaust gas recirculation servomotor V338Cylinder head coolant valve N489 Exhaust gas recirculation cooler change-over valve N345Exhaust turbocharger control unit 1 J724Intake manifold flap motors 1 and 2 V157, V275Auxiliary signals: – Air-conditioning compressor – Auxiliary coolant heater – Fan settings 1 + 2 – Auxiliary air heater element Z35Control unit for catalytic converter heater 1 J10211) Catalytic converter heater 1 Z1191) Electro/hydraulic engine mounting solenoid valve, left and right N144, N145 Reducing agent metering system control unit J880 Reducing agent injector N474 Reducing agent line heater Z104 Reducing agent pump V437 Reducing agent transfer pump V436 Reducing agent tank heater Z102Oxygen sensor heater Z19Fuel pump relay J17 Fuel predelivery pump G6 Auxiliary fuel pump relay J832 Auxiliary fuel pump V393622_0121)Installed in a limited number of models only.29Reducing agent pump V437The reducing agent pump V437 (metering pump) is housed inside the swirlpot. A so-called "brushless motor" is used in the metering pump. This type of electric motor is also known as an electrically commutated three-phase motor. The brush assembly of copper plates and carbon brushes has been replaced by intelligent electronics.Integrated in the swirlpot: reducing agent pump V437622_059FunctionThe engine control unit activates the SCR metering pump electronics by sending CAN signals to the SCR control unit, which in turn activates the components by means of analogue signals. To make the rotor rotate, a three-phase AC field must be generated. This means that the brushless motor actually acts as a three-phase AC motor, and the three-phase AC field is generated artificially. The stator coils are activated in such a way that a rotating magnetic field is generated in the stator coils. The rotor is forced by the permanent magnet pairs to continuously realign itself and thereby follow the magnetic field lines. This causes the rotor to rotate. The position of the rotor is detected by the reducing agent metering system control unit J880 via the de-energised coil pair. This feedback signal is also known as a "back EMF" signal (EMF = ElectroMotive Force).Functional principleStator RotorCoil winding circuitsOutput stageElectronic control unit 622_061Back EMF signalPermanent magnetCoil622_06030Reducing agent tank sender G684 (level sender)The second-generation SCR level sender differentiates between seven individual reducing agent levels ranging from "empty" to "full". The downward movement of the float is limited by the design of the level filter housing. The upward movement of the float is limited by a retaining disc. When the reducing agent expands in frosty conditions, the retaining disc gives the float enough freedom of movement to allow for expansion. Fill level characteristicAll switches open (full) Switches 6 and 7 Switch 5 Switch 4 Switch 3 Switch 2, reserve Switch 1, "empty"ResistanceNo restartAdBlue® level622_051Installation location and designFloat with magnetsRetaining discReducing agent tank sender G684622_016Refilling Depending on model and tank system, between three and four 0.5 gal Kruse bottles (5.7 l – 7.6 l) are needed to refill the tank and thereby reset the sensors. The relevant information is displayed on the adhesive label in the fuel filler flap. One gallon (gal) is the equivalent of about 3.8 litres.Adhesive label for European spec models (example)Adhesive label for US spec models (example)622_062622_052 31Particulate sensor G784 with control unit(to be introduced at a later date) The particulate sensor is integrated in the exhaust downstream of the particulate filter and allows for diagnosis of the particulate filter.Method of operation The sensor element works on the resistance measurement principle. Deposited soot particles form electrical pathways between the electrode chambers, to which an electrical current flows. The sensor element is regenerated by regular heating. The diagnostic software responsible for the diesel particulate filter assesses the performance of the diesel particulate filter based on the measured electrical current.622_045Reducing agent injector N474 (metering valve)The metering system reducing agent (AdBlue®) in an exhaust system includes a control valve, a metering valve and a cooling unit. The cooling unit configured as a cooling jacket. It is integrated in the engine coolant circulation system and provides for effective cooling of the metering valve. Coolant flows through the injector along coolant ducts. With this so-called counterflow cooling system, the cooled coolant enters the injector at the bottom and flows through the injector before being released back into the cooling system at the top of the injector.Coolant outlet Coolant inlet Electrical connection Connection for AdBlue® lineAdBlue® outlet622_03832Connection to the cooling system of the 3.0l V6 TDI engine on the Audi A8 ’14Reducing agent injector N4741234567 9871011714 1312151617622_029Key: 1 2 3 4 5 6 7 8 9 Front heater heat exchanger Rear heater heat exchanger Coolant circulation pump V50 Transmission oil cooler (ATF heat exchanger) Gearbox coolant valve N488 Injector for reducing agent N474 Non-return valve Coolant expansion tank Coolant temperature sender G62 10 11 12 13 14 15 16 17 EGR cooler Coolant shutoff valve Alternator Engine oil cooler Oil temperature sender G8 Temperature sender for engine temperature regulation G694 Coolant thermostat Coolant pumpCooled coolantHeated coolantATF33Connection to the cooling system of the 2.0l V6 TDI engine on the Audi A8 ’14Reducing agent injector N474 1 27 3 8 9 10 8 4 6 5 12 1311622_030Key: 1 2 3 4 5 6 7 Coolant temperature sender G62 Coolant thermostat Charge air cooling pump V188 Injector for reducing agent N474 Intercooler integrated in intake manifold Intercooler coolant radiator Coolant pump 8 9 10 11 12 13 Non-return valve Throttle valve Engine oil cooler Radiator Radiator fan 1 V7 Radiator fan 2 V177Cooled coolantHeated coolantATF34Display strategyOverviewDepending on the fill level of the reducing agent tank, various messages are displayed in the instrument cluster, some requiring the assistance of a special workshop or that the reducing agent tank be refilled with AdBlue®. Faults in the SCR system are also indicated by corresponding messages. The various messages are summarised in the table below. The style of display can vary depending on model and instrument cluster version.SCR warning strategy, text messages and audible signalsRemaining range from 2400 km or 1500 miles Display Warnings given via the display in the instrument cluster are also indicated by a gong tone. The remaining range is decremented in increments of 100 km or 100 miles. A warning is given via the display at intervals of 400 km or 400 miles, or every 8 hours. Colourfrom 1,100 km or 700 milesThe remaining range is decremented in increments of 50 km or 50 miles. A warning is given via the display at intervals of 100 km or 100 miles, or every 8 hours.from 1,000 km or 600 milesThe remaining range is displayed together with a buzzer tone and a warning that it will not be possible to restart the engine when the remaining range expires. The remaining range is decremented in increments of 50 km or 50 miles. A warning is given via the display at intervals of 100 km or 100 miles, or every 4 hours.from 200 km or 100 milesOnce the reducing agent range decreases to less than 200 km or 100 miles, the remaining range is decremented in increments of 10 km or 5 miles. A warning is given via the display at intervals of 20 km or 10 miles, or every 8 hours.at 0 km or 0 milesA warning that it will not be possible to restart the engine is given via the display in the instrument cluster and a buzzer tone sounds three times.35Messages relating to reducing agent fill levelThe displayed remaining range is calculated based on the residual amount of reducing agent in the tank and the rate of reducing agent consumption. When the reducing agent range drops to 2400 km or less, a warning is sent to the instrument cluster. The warning is repeated on the basis of elapsed time or distance.Fill level, stage 1This driver warning appears if the AdBlue® level is sufficient only for the remaining range indicated via the driver information system. AdBlue® must be added. The displayed remaining range is calculated based on the residual amount of reducing agent in the tank and the rate of reducing agent consumption, starting at 2400 km. The remaining range is displayed in increments of 100 km.Refill AdBlue Range 2,400 km See owner's manual622_055Fill level, stage 2This driver warning appears if the AdBlue® level is sufficient only for the remaining range indicated via the driver information system. AdBlue® must be added. Otherwise, you will not be able to restart the engine after the indicated range has expired. The remaining range is displayed in increments of 50 km.Refill AdBlue No restart in 1000 km See owner's manual622_056Fill level, stage 3This driver warning is displayed if the AdBlue® reducing agent tank is empty. AdBlue® must be added. Otherwise, the engine will not restart after turning off the ignition.Refill AdBlue No restart See owner's manual622_05336Fault warningsAn SCR system fault immediately triggers the remaining range display, regardless of the actual tank fill level. The remaining range is decremented by the distance covered and is not dependent on reducing agent consumption. The SCR system fault is activated if one of the following event memory entries is indicated: • A fault in an SCR system component relevant to operation, e.g. the delivery pump, the reducing agent injector, the pressure sensor, the pressure regulator, the SCR control unit or wiring and the CAN interface. • A large difference between nominal and actual reducing agent consumption • Detection of a reducing agent misfill.System malfunctionIf the AdBlue® tank has been filled with a fluid other than AdBlue® and a misfill is detected by the system or a system fault exists, a driver warning is displayed.AdBlue: System malfunction622_057System fault with imminent restrictions on engine startingThis driver warning is displayed if the vehicle has only the remaining range indicated in the driver information system. Proceed to the nearest authorised Audi service centre and have the fault corrected. Otherwise, you will not be able to restart the engine after the indicated range has expired. After another 50 km have been covered, the yellow warning lamp comes on to indicate a system fault.AdBlue: System malfunction No restart in 1000 km See owner's manual622_058System fault with restrictions on engine startingThis driver warning is indicated if a misfill has been detected or if a system fault exists. Proceed to the nearest authorised Audi service centre and have the fault corrected. Otherwise, the engine will not restart after turning off the ignition.AdBlue: System malfunction No restart See owner's manual622_05437ServiceToolsVAS 6557 SCR vacuum box VAS 6532 SCR test box622_036622_037Extracting AdBlue® from the SCR systemAssessment of the SCR system in connection with "Guided Fault Finding"VAS 6542 AdBlue® filling unitVAS 6606 198-pin isolating box -1- and VAS 6606/10 Test adapter -21 2 2622_035622_034Filling the reducing agent tank prior to pre-delivery vehicle inspection or during a relevant service eventDiagnostics of control units with 198-pin terminals (UDS control units)T40268 Wrench622_039Removing the swirlpot from the SCR tank38AnnexSelf Study ProgrammesFor further information about the technical features of Audi EU 6 diesel engines with SCR system, refer to the following Self Study Programmes. SSP 428 Audi 3.0l V6 TDI engine with ultra low emission system (EU6, LEV II, BIN5) • Information on the design and function of an SCR system • How to handle AdBlue® face to face with the customer and in the service workshop Order number: A08.5S00.56.20SSP 479 The Audi 3.0l V6 TDI engine (second generation) Information on the 3.0l V6 TDI engine • Mechanicals • Oil supply • Air circulation and charging • Common rail injection system • Cooling systemOrder number: A10.5S00.72.20SSP 608 The Audi 1.6l and 2.0l 4-cylinder TDI engines Information on the 2.0l R4 TDI engine • Mechanicals • Oil supply • Air circulation and charging • Common rail injection system • Cooling systemOrder number: A12.5S00.92.20SSP 625 Audi A3 saloon Information on the 2.0l R4 TDI engine in the MQB • SCR tank with in-tank SCR dosing module • Exhaust systemOrder number: A13.5S01.09.2039Audi Vorsprung durch TechnikAll rights reserved. Technical specifications are subject to change. Copyright AUDI AG I/VK-35 service.training@audi.de AUDI AG D-85045 Ingolstadt Technical status 10/13 Printed in Germany A13.5S01.06.20622