TECHNICAL DOCUMENTATION
SSP 980193 – The 2019 Audi A8 Climate Control Systems

This PDF is currently unavailable.
Read document text
The 2019 Audi A8 Climate Control SystemseSelf-Study Program 980193Audi of America, LLC Service Training Created in the U.S.A. Created 5/2018 Course Number 980193©2018 Audi of America, LLC All rights reserved. Information contained in this manual is based on the latest information available at the time of printing and is subject to the copyright and other intellectual property rights of Audi of America, LLC., its affiliated companies and its licensors. All rights are reserved to make changes at any time without notice. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, nor may these materials be modified or reposted to other sites without the prior expressed written permission of the publisher. All requests for permission to copy and redistribute information should be referred to Audi of America, LLC. Always check Technical Bulletins and the latest electronic service repair literature for information that may supersede any information included in this booklet.Revision:May 25, 2018iiIntroduction The new R744 refrigerant Global Warming Potential12 4Design of the R744 refrigerant systemSchematic diagram and function description AC compressor Gas cooler Internal heat exchanger Pressure relief valve, low and high-pressure sides Expansion valve Accumulator Refrigerant lines Refrigerant pressure and temperature sensors G1052 / G1053 Vehicle Interior Carbon Dioxide Concentration Sensor G929 Components of the R744 refrigerant circuit Topology55 6 7 8 9 10 11 12 14 15 16 18Air quality and freshening qualityInterior fragrance system Air improvement system2020 21AC control panels in the front and rearFront area Rear area2222 24Seats and available functionsMassage function Surface heating Foot heater Optional seat heating and ventilation2626 28 29 29Workshop equipmentA/C service station Service connections3030 31AppendixeSelf-Study programs3232Knowledge assessment33The eSelf-Study Program (eSSP) teaches a basic understanding of the design and mode of operation of new models, new automotive components or new technologies. It is not a repair manual! Figures are given for explanatory purposes only and refer to the data valid at the time of preparation of the SSP. For further information about maintenance and repair work, always refer to the current technical literature.NoteReferenceiiiivIntroductionThe climate control system of the 2019 Audi A8 will mark the introduction of a new refrigerant as well as new in-car air quality enhancements. The new refrigerant is carbon dioxide-CO2. It has different physical properties than other refrigerants in use. For example, it is non-flammable, colorless and odorless. Because a carbon dioxide charged system will operate at much higher pressures, the components of the refrigerant system have been adapted. The new refrigerant will only be offered in Europe at the launch of the 2019 A8. The dates for implementation in the US have not been determined at the time of the release of this SSP. For the North American market, the 2019 A8 will use refrigerant R-1234yf at vehicle introduction. The new 2019 also offers air quality features such as a cabin fragrance system and an air improvement system.665_002Learning objectives of this eSelf-Study Program: This eSelf-Study Program describes the new features of the climate control system in the 2019 Audi A8, as well as the design and function of the refrigerant system filled with the new R744 refrigerant introduced in this model. Once you have completed this eSelf-Study Program you will be able to answer questions on the following topics: ›› How is the air conditioning system configured for use of the new R744 refrigerant? ›› What are the points to note when servicing the cabin fragrance system function unit? ›› What are the new display and control features of the air conditioning system? ›› What new massage functions are available in the new Audi A8?1The new R744 refrigerantThe new refrigerant is carbon dioxide. It has the chemical formula CO2 and is also known as R744. It contains neither fluorine nor chlorine and is produced in a series of natural processes without the possibility depleting the Earth's ozone layer. CO2 is a colorless, non-flammable gas and is chemically slow to react with with other elements. Carbon dioxide is heavier than air. It is a naturally occurring substance which is available at an affordable price. In the event that the refrigerant circuit should incur a leak, the refrigerant can enter the atmosphere without causing damage to the environment. Carbon dioxide can exist in solid, liquid, gaseous and supercritical states, but it only occurs in gaseous, liquid and supercritical states in automotive refrigerant systems systems. CO2 based refrigerant systems operate at 10 times the pressure of systems filled with the refrigerants used previously. The system has to be sealed more tightly because CO2 molecules are smaller than the molecules of other refrigerants. R744 refrigerant is a natural substance. It may be discharged into the environment and is not subject to the documentation requirements which apply to chemical refrigerants.Features Chemical formula Chemical name Boiling point at 14.5 psi (1 bar) (absolute pressure) Freezing point Triple point – Pt Critical point – Pc Purity (for refrigerant circuits in Audi models) Flammability Form Color Odor CO² Carbon dioxide 109.6 °F (-78.7 °C) -69.8 °F (-56.6 °C) -69.8 °F (-56.6 °C) at 75.4 psi (5.2 bar) (absolute) 87.8 °F (73.8 bar) at 73.8 bar (absolute) 99.995 % Non-flammable Compressed, liquefied gas Colorless No inherent odorNote The new refrigerant will only be offered in Europe at launch. The dates for implementation in the US have not been determined at the time of the release of this SSP. about not available at launch.Note The R744 refrigerant odes not have an inherent odor and therefore is not noticeable. However, the refrigerant gas is heavier than air and can accumulate in lower-lying areas such as inspection pits, basement rooms, where it displaces the ambient air and oxygen. Working in areas with a low oxygen level can have life-threatening consequences.2Phase diagram for carbon dioxide – CO₂CO2 (s)CO2 (sc)CO2 (l)73.8PcCO2 (g) Pressure in bar 5.2 1.0665_022Pt-78.7-56.631.1Temperature in SDgrCThe phase diagram showing the solid (s), liquid (l), gaseous (g) and supercritical (sc) phases of carbon dioxide is not to scale.Properties of the R744: A supercritical situation can occur in the R744 refrigerant circuit. The critical point is when a substance enters a thermodynamic state, where the densities of the liquid and gas phases become equal and the distinction between them disappears. In a supercritical situation, the state of the refrigerant in the gas cooler does not change from gaseous to liquid state, but rather is cooled only. Hence the term "gas cooler". Due to the higher energy content of CO2, a lower mass flow rate is required in order to achieve the same refrigerating capacity. In addition to increasing the refrigerating capacity of the system, this advantage can be used to realize a more compact unit design and to reduce the flow component cross-sections.3Global Warming PotentialThe Global Warming Potential (GWP) describes the relative global warming effect of a greenhouse gas, that is, how much a gas potentially contributes to the warming of the Earth's atmosphere. The reference value used as the basis for comparison is that of carbon dioxide (CO2), which has a GWP of one. The smaller the GWP value, the lesser the potential global warming effect and, by implication, the less the impact on the environment. For example, R1234yf has a GWP of four for a time horizon of 100 years. This means that one kilogram of R1234yf has four times the global warming effect of one kilogram of CO2 within the first 100 years after its release into the environment. Starting from 1 January 2017, vehicles using a refrigerant with a GWP value of greater than 150 cannot be type-approved in European Union countries. For this reason, the use of refrigerants such as R134a is prohibited in these countries. For this reason, Audi has been using the R1234yf refrigerant as standard since 2016 in many countries. With the launch of the new Audi A8, carbon dioxide is available as an alternative refrigerant.Properties of the various refrigerantsRefrigerant Ozone layer depletion Global Warming Potential (GWP) Year of use in vehicle R12 (CFCs) Yes R134a (HFCs) No R1234yf (HFCs) No R744 (CO₂) NoAbout 10,000x that of CO₂ Up to 1992About 1,400x that of CO₂ From 1991 onwardsAbout 4x that of CO₂ From 2016 onwards1xUS date TBDRefrigerant typeSyntheticSyntheticSyntheticNaturalFlammableNoNoYesNoPressure 435.1 psi (30 bar) 435.1 psi (30 bar) 435.1 psi (30 bar) 2030.5 psi (140 bar)4Design of the R744 refrigerant systemSchematic diagram and function descriptionThe key difference to the previously used refrigerant systems is the high working pressures. Higher pressures are required to make use of C02 as a refrigerant. R744 will operate at a pressure of about 2030.3 psi (140 bar) on the high pressure side of the circuit and about 1348.8 psi (93 bar) on the low pressure side.High Pressure Side A/C Pressure/Temperature Sensor G1053 Service connection High pressure Internal heat exchangerGas coolerExpansion valveService connection Low pressurePressure relief valve Low-pressure side Low Pressure Side A/C Pressure/Temperature Sensor G1052EvaporatorPressure relief valve High-pressure side CompressorAccumulator665_023Component designation Compressor Gas cooler Internal heat exchanger Expansion valve Evaporator Accumulator Internal heat exchangerProcesses in the refrigerant circuit Compression of gaseous CO₂ to a higher pressure level Cooling of the refrigerant Heat is dissipated in the internal heat exchanger. Heat is transferred from the high-pressure side to the low-pressure side. When refrigerant expands in the expansion valve, the pressure is reduced by restricting the flow. The refrigerant absorbs energy from the air flowing through the evaporator. The accumulator dries and stores the refrigerant and provides a place for the oil and refrigerant to mix. Heat is absorbed in the internal heat exchanger. Heat is transferred from the high-pressure side to the low-pressure side.5AC compressorThe AC compressor compresses the gaseous refrigrant so that it can subsequently be allowed to expand again inside the evaporator. The expansion of the refrigerant causes the temperature to drop, allowing heat to be extracted from the passenger compartment. The refrigerant compressor works on the same principle as an axial piston pump or axial piston compressor, with fixed pistons spaced at even intervals around the inner circumference of working cylinders and mounted movably on a rotating swashplate. By following the tilt of the swashplate, the individual pistons move in a reciprocating linear manner inside their cylinders, with the result that refrigerant is drawn into the compressor, compressed inside the piston chamber and then pumped into the refrigerant circuit. The tilt angle of the swashplate is variable, and changes the resultant mass flow. The angle of the swashplate regulates itself according to the required mass flow. Specifications of the compressor: ›› 9 pistons. ›› 31 cm³ stroke volume. ›› Mass flow controlled.Refrigerant line connection High pressureConnection to 12-volt electrical systemPressure relief valve High-pressure side Refrigerant line connection Low pressure Oil drain boltBelt pulley with solenoid couplingA/C Compressor Regulator Valve N280665_0036Gas coolerThe gas cooler is a newly developed component which takes the place of the condenser. It cools the refrigerant down. The gas cooler dissipates process heat of the high pressure side to the atmosphere. It is designed for both supercritical operation (as a "gas cooler") and alternating phase operation (as a "condenser"). The term "alternating phase" defines a refrigerant whose aggregate state alternates between gaseous and liquid. The gas cooler is made of flat tubes. Inside the flat tubes, smaller tubes are bundled longitudinally. The flat tubes themselves are arranged in a row next to one another. The refrigerant flows through the gas cooler into the upper segments and then back to the lower segments in the opposite direction. High Pressure Side A/C Pressure/Temperature Sensor G1053 is located at the gas cooler.High Pressure Side A/C Pressure/Temperature Sensor G1053665_0047Internal heat exchangerThe internal heat exchanger is similar to the Coolaxial pipe used in other Audi model refrigerant systems. The internal heat exchanger is a tube-in-tube heat exchanger consisting of an inner high-pressure tube enveloped by low-pressure tubes. The refrigerant flowing through the low-pressure tubes absorbs heat. In the high-pressure tube, the refrigerant flowing in the opposite direction gives off heat. This allows energy to be exchanged between the low and high-pressure sides. The principal task of the internal heat exchanger is to increase the efficiency of the refrigerant circuit. This is achieved by extending the circulation process to increase the enthalpy difference at the evaporator. For this purpose, the internal heat exchanger using refrigerant R744 is required to be about a yard (meter) long. Note: Enthalpy is defined as a thermodynamic quantity equivalent to the total heat content of a system. It is equal to the internal energy of the system plus the product of pressure and volume.Internal heat exchanger665_005High-pressure sideLow-pressure side8Pressure relief valve, low and high-pressure sidesProtective filmAdjusting screwSpringBall seat Aluminum housing Steel ballSensorGasket seat665_006Refrigerant connectionFunctional principleIf overpressure occurs in the refrigerant circuit, a steel ball in the valve is pressed against a spring. This opens passage which is closed at normal pressure, allowing the refrigerant to escape. Both pressure relief valves are reversible valves. The valve is leak-tested using gas prior to shipping. The pressure relief valves protect the refrigerant circuit against excessively high pressures. The pressure relief valve on the low-pressure side opens when an excessively high pressure occurs in the refrigerant circuit when the system is switched off. This can occur if the refrigerant is heated in warm ambient conditions, causing the system pressure to increase. The pressure control valve opens at a pressure of about 1740.4 psi ± 145 psi (120 bar ± 10 bar) The pressure relief valve on the high-pressure side opens if an excessively high system pressure occurs due to a fault in the control system or a damaged or clogged line on the high-pressure side. In this case, the pressure control valve opens at a pressure of about 2320.6 psi ± 145 psi (160 bar ± 10 bar). Two valves have different diameters to prevent from being installed in the wrong locations. Both valves have a lefthanded thread. A valve with an M12x1 thread is used on the high-pressure side and a valve with an M14x1 thread on the low-pressure side. The valves have different tightening torques. The pressure relief valve on the low-pressure side is located at the block connection from the internal heat exchanger. The pressure relief valve on the high-pressure side is located directly at the AC compressor.Note If the valve has opened, it will be indicated by a broken protective foil. An opened valve must be replaced. The refrigerant must be evacuated completely before removing the valves.9Expansion valveThe expansion valve is the interface between the high and low-pressure sides. The task of this valve is to expand and cool the highly pressurized refrigerant at a low pressure level. It acts as a high-pressure-controlled expansion element for the evaporator. The refrigerant is expanded at medium and high load using a defined bore diameter of 0.55 mm. At high load, an additional bypass flow is opened in a controlled manner by a spring.Adjusting springMetallic gasket Refrigerant (high pressure / atmosphere)FilterMetal bellowsClosing element with 0.55 mm bore diameterBypass seat with defined bore diameterAluminum housing665_007EvaporatorThe task of the evaporator is to extract heat the passenger compartment. The evaporator consists of flat tubes, in each of which small tubes are bundled longitudinally. The refrigerant is circulated several times through these tubes. They are arranged in two vertical rows (one behind the other) inside the evaporator. The key here is that the refrigerant mass flow is distributed evenly to all flat tubes.10AccumulatorThe accumulator is integrated into the refrigerant circuit on the low-pressure side between the evaporator and the internal heat exchanger. It has a diameter of about 2.95 in (75 mm) and is built into the wheel well on the driver's side under the A pillar. The accumulator has the following tasks: ›› Header / reservoir for non-circulating refrigerant. ›› Reservoir for refrigerant oil. ›› Drying and extracting water from the circulating refrigerant. The accumulator ensures that the refrigerant is of the optimal quality, that is, having the ideal vapor content for the internal heat exchanger. After the refrigerant enters the accumulator it comes into contact with the baffle plate, where the liquid phase is separated from the gaseous phase. Excess refrigerant is stored in the header after it has been filtered and dried. The refrigerant oil is also filtered and flows through a bore in the intake manifold into the refrigerant circuit leading to the AC compressor together with the refrigerant emerging from the accumulator.InletOutletBaffle plateFilterHeader GranulateBoreOil filter665_00811Refrigerant linesRefrigerant lines on hot gas sideThe refrigerant on the hot gas side is a hose and pipe connection from the compressor to the gas cooler.Refrigerant lines on high and low-pressure sidesThe refrigerant lines on the high and low-pressure sides are hose or tube connections without a corrugated tube reinforcement.Corrugated tube reinforcement665_024665_025The high temperatures of the compressed refrigerant necessitate channeling it through a corrugated metallic pipe held in shape by a steel-fiber reinforced tubing.Working pressure in the refrigerant lines›› The working pressure is approximately 2030.5 psi (140 bar). ›› The refrigerant lines are designed for temperatures from approximately -40 °F to 356 °F (-40 °C to 180 °C).Note If repairs are needed, the complete refrigerant system must always be checked for an absence of pressure. There should be absolutely no pressure in the system. Close attention must be paid to cleanliness. The connections must be perfect before tightening. The refrigerant lines must not be flexed and the refrigerant hoses must not be kinked during the tightening, removal or re-installation procedures.12Connection systemThe refrigerant lines have special gaskets which are designed to withstand the high pressures within the refrigerant circuit and to seal it against the atmosphere. The actual metal gasket is located inside the locking device (yellow element). The refrigerant lines are interlocked with the locking device by a pin. The locking device, including the gasket as well as the retaining bolt, must be replaced whenever the refrigerant lines are repaired. This is necessary in order to ensure the maximum integrity of the refrigerant system. When carrying out this work, pay close attention to cleanliness and make sure that the gasket is properly seated during installation. It is also important to make sure that the sealing faces are oil and grease free before installing the refrigerant lines.Refrigerant lineMetallic gasketLocking devicePinRetaining bolt665_013Note The metallic gasket can only seal the system if the retaining bolt is tightened to the correct specified torque value.13Refrigerant pressure and temperature sensors G1052 / G1053The refrigerant pressure and temperature sensors G1052 and G1053 have different tasks and installation positions. The tasks for Low Pressure Side A/C Pressure/Temperature Sensor G1052 are to supply signals for low pressure control and low fill level detection. It is attached to the low pressure line on the output side of the accumulator. The tasks for High Pressure Side A/C Pressure/Temperature Sensor G1053 are to supply signals for high pressure and hot gas temperature control, in order to protect the components of the compressor. It is attached to the high pressure line directly at the inlet side of the gas cooler. The refrigerant pressure and temperature sensors G1052 and G1053 are only installed in systems equipped with a CO₂ climate control. The reason for this is that CO₂ climate control systems operate at high pressures. If either or both of these sensors needs to be replace due to repair work, the complete refrigerant circuit must be evacuated. The two sensors must never be loosened when system is active and under high pressure because they are integrated directly in the refrigerant circuit. G1052 and G1053, have neither a safeguard nor a pressure relief valve.Low Pressure Side A/C Pressure/Temperature Sensor G1052High Pressure Side A/C Pressure/Temperature Sensor G1053665_00914Vehicle Interior Carbon Dioxide Concentration Sensor G929(for European vehicles only) G929 is located in the passenger compartment under the glove compartment. The working principle of the sensor is based on measuring the wavelength-dependent radiation characteristics of carbon dioxide (CO₂).665_012The task of Vehicle Interior Carbon Dioxide Concentration Sensor: ›› Measurement of cabin CO₂ concentration in driving mode and when parking. Intervention points: ›› The intervention point varies depending on operating state. ›› At low CO₂ concentration levels during normal operation. ›› At elevated CO₂ concentration levels in air recirculation mode. ›› At high CO₂ concentration levels in the parked vehicle.The following steps are taken if excessively high CO₂ levels are detected: ›› The ambient air supply is increased by opening the ambient air flap / air recirculation flap in order to reduce CO₂ concentration levels. If the CO₂ concentration level continues to rise, the speed of the cabin fan is increased to the maximum level. ›› If the concentration level rises still further, the driver information system in the instrument cluster issues the following warning: "Air conditioning system: high CO₂ concentration. Ventilate vehicle. See owner's manual“. ›› If high CO₂ values are detected inside the parked vehicle, the fan is started by Vehicle Electrical System Control Module 1 J519.15Components of the R744 refrigerant circuitThe illustration provides a location overview of the components described on the previous pages.Service connection, low-pressure sideConnection to evaporatorGas coolerSystem pressure›› The system pressure on the low-pressure side is about 1348.8 psi (93 bar). ›› The system pressure on the high-pressure side is about 2030.5 psi (140 bar).High Pressure Side A/C Pressure/Temperature Sensor G1053AC compressor with pressure relief valve, high-pressure side16Service connection, high-pressure sideExpansion valveLow Pressure Side A/C Pressure/ Temperature Sensor G1052AccumulatorInternal heat exchangerPressure relief valve, low-pressure side665_01117TopologyData Link ConnectorFront Information Display Control Head J685Front Information Display Control Head 2 J1060Data Bus on Board Diagnostic Interface J533Information Electronics Control Module 1 J794Air Quality Sensor G238Left Rear Air Distribution Motor V593Left Footwell Door Motor V108Left Rear Air Door Motor V239Exterior Air Quality and Humidity Sensor G935Humidity Sensor in Fresh Air Intake Duct G657Left Footwell Vent Temperature Sensor G261Right Footwell Vent Temperature Sensor G262Evaporator Vent Temperature Sensor G263Vehicle Electrical System Control Module 1 J519A/C Compressor with Magnetic Clutch and Regulator Valve VX81Speed Sensor 4 G656Vehicle Interior Carbon Dioxide Concentration Sensor G929Rear Sunlight Photo Sensor G914A/C Compressor Regulator Valve N280Air Ionization System Control Module J897Driver Side Ionizer J1105Front A/C Display Control Head 1 E774Front A/C Display Control Head 2 E775A/C Clutch N25Low Pressure Side A/C Pressure/Temperature Sensor G1052Front Passenger Side Ionizer J1106Right Rear Upper Body Vent Motor V316Right B-Pillar/Footwell Shut-Off Door Motor V211Air Freshening System Control Module J1101High Pressure Side A/C Pressure/Temperature Sensor G1053Fragrance Diffuser System Blower V686Left Side Window Defroster Door Motor V409Left Air Vent Cover Motor V207Center Air Vent Cover Motor V208Right Air Vent Cover Motor V209Right Side Window Defroster Door Motor V410Fragrance System Functional Unit GX43Fresh Air Blower Control Module J126Fresh Air Blower V2Fragrance Diffuser System Temperature Sensor G1056 Fragrance Diffuser System Actuator V687Auxiliary Heater Control Module J604Auxiliary Heater Heating Element Z35Fresh Air Door Motor V438Recirculation Door Motor V11318Auxiliary Display Control Head 1 E857Wireless Control Head 1 E859Right Rear Air Door Motor V240Right Center Vent Motor V111Defroster Door Motor V107Left Side Vent Motor V299Left Temperature Control Door Motor V158Left Center Vent Motor V110Right Temperature Control Door Motor V159Right Rear Air Distribution Motor V594Right Footwell Door Motorr V109Right Side Vent Motor V300Right Rear Heated Seat Temperature Sensor G95Right Rear Seat Backrest Temperature Sensor G809Left Front Upper Body Vent Temperature Sensor G385Right Front Upper Body Vent Temperature Sensor G386Position Sensor in Left Center Vent G626Position Sensor in Right Center Vent G627Right Rear Bench Seat Heating Element Z12Right Rear Backrest Heating Element Z13Rear A/C Display Control Head E265Switch Module in Instrument Panel, Center EX22Left Rear Bench Seat Heating Element Z10Left Rear Backrest Heating Element Z11Front A/C Display Control Head 3 E776Front A/C Display Control Head 4 E777Front A/C Display Control Head 5 E778Rear Window Defogger Button E230Left Rear Heated Seat Temperature Sensor G94Left Rear Seat Backrest Temperature Sensor G808Left B-Pillar/Footwell Shut-Off Door Motor V212Left Rear Upper Body Vent Motor V315Front A/C Display Control Head 6 E884Rear Fresh Air Blower Control Module J391Rear Fresh Air Blower V80Key:Infotainment CAN Comfort/convenience systems CAN 2 MIB CAN Diagnostics CAN LIN bus Discrete cable Ethernet port for diagnose interface VAS 6154665_01519Air quality and freshening qualityInterior fragrance systemAn air freshening system will be offered on the 2019 Audi A8 in addition to the air quality functions used on the previous model. There is a choice of two fragrances: a summer fragrance and a winter fragrance. The choice of scent and scent intensity can also be set via Front Information Display Control Head J685 while driving. The actual scent fill level is also indicated. The fragrances are stored in two cylindrical bottles in Fragrance System Functional Unit GX43 located to the left of the steering wheel below the instrument panel. A small fan the blows the fragrance from the container into the outer front air outlets. The fragrance bottles are referred to as “flacons” in the service literature.Overview of aromatization and air quality systemsAir Freshening System Control Module J1101Driver Side Ionizer J1105Front Passenger Side Ionizer J1106Fragrance Diffuser System Blower V686Air Ionization System Control Module J897 Hose665_016Fragrance System Functional Unit GX43Fragrance bottle 1 Fragrance bottle 2Each of the bottles used in the Fragrance System Functional Unit GX43 is labelled with the fragrance it contains.Note The fragrance bottles are only replaceable by service personnel. After replacement, Air Freshening System Control Module J1101 must be adapted using the VAS Scan Tool.Note To avoid installation errors, the bottles should be replaced in sequence. Both fragrance bottles have left hand threads.20Air improvement systemIonizers improve air quality through the controlled negative charging of air particles before they are discharged into the interior from the outer front air outlets. The negative ions in the air can help enhance the well-being and concentration of the vehicle's occupants. Ionization can reduce the concentration of harmful airborne particles and germs and improves air quality inside the interior. The two ionizers, Driver Side Ionizer J1105 and Front Passenger Side Ionizer J1106 can be replaced individually. The electrodes can be replaced separately and must not be damaged. It is important to pay attention to the color codings of the wires when installing new electrodes.Air Ionization System Control Module J897Front Passenger Side Ionizer J1106Ionizer electrodes665_03521AC control panels in the front and rearFront areaThe Audi A8 no longer requires the Climatronic Control Module J255. The AC is operated via two touchscreens. Control is now implemented in Vehicle Electrical System Control Module 1 J519. The LIN bus system is used for communication between J519 and the participating AC components. Refer to the topology for further information. In terms of visual appearance and tactile feel, both displays are the key innovation in terms user operation. The upper MMI display and the lower touchscreen are installed at the center of the instrument panel and at the center of the center console respectively. The climate control functions in the upper MMI display can be accessed via the Car menu.Overview of the MMI display for AC operation665_019Depending on trim level, the following functions and their settings can be selected at Front Information Display Control Head J685: ›› ›› ›› ›› ›› ›› Ionization. Aromatization. Steering wheel heating. A/C synchronization for driver and front passenger sides. Climate control for rear occupants / for rear. Climate control.22Overview of lower touchscreen for climate control operation665_020Individual climate control functions can be set separately for the driver and front passenger sides with Front Information Display Control Head 2 J1060. ›› ›› ›› ›› ›› ›› ›› Temperature. Fan speeds. Air distribution. Seat heater. Seat ventilation. Climate control functions. Air recirculation. ›› Rear roller blind operation. ›› Zoom in display. (creates space for shortcuts in upper half of screen). ›› Automatic start/stop. ›› Switching display on / off.Overview of climate control synchronization functionHome665_021The climate control settings can also be synchronized by using a touch control feature. Synchronization is activated by pinching two fingers together and deactivated by spreading two fingers apart.23Rear areaVarious control panels are available for the rear seat occupants, depending on trim level. A new control panel, the Rear Seat Remote, will be available as an option at the Start of Production (SOP) of the new Audi A8. Two buttons are available for operation of the seat heating in standard trim: Left Seat Heating Button E653 and Right Seat Heating Button E654. These buttons are connected discretely to Vehicle Electrical System Control Module 1 J519.Note Seat Heating Control Module J882 is not accessible via the VAS Scan Tool.Rear Seat RemoteThe Rear Seat Remote unit has: ›› Vertical Control Button (Down) in Driver Seat Switch Module E869. ›› Auxiliary Display Control Head 1 - E857. The holder is a separate CAN control module integrated in the MIB CAN. Both front displays have similar functions, layout and appearance. The Rear Seat Remote is also operated via a touchscreen.665_02624Control panels to be introduced at a later dateRear A/C Display Control Head E265 will be available for rear seat occupants as an option. It does not have a sensory surface. This control panel can be used to set the seat heating in addition to temperature and blower speed665_036A control panel with a sensory surface will be optionally available as an additional control panel for the rear seat occupants. The following settings can be made: ›› ›› ›› ›› ›› ›› Temperature. Fan speed. Air distribution. Automatic climate control. Climate control on / off. Seat heater.665_027Setting the fan speedThe fan speed can be adjusted by “sliding” any of the four front or two rear touch sliders. The sliders have the following designations:Left front area Center left front area Center right front area Right front area Center left rear area Center right rear area Front A/C Display Control Head 1 E774 Front A/C Display Control Head 2 E775 Front A/C Display Control Head 3 E776 Front A/C Display Control Head 4 E777 Front A/C Display Control Head 5 E778 Front A/C Display Control Head 6 E88425Seats and available functionsMassage functionBack massageAn enhanced back massage function is available in the new Audi A8. Up to 16 bladders are integrated in the front seat and up to 18 in the rear seat. In standard trim, the seats are equipped with double lift bladders. The optional triple lift bladders are designed to provide a higher intensity back massage. For a back massage, there is a choice of three intensity levels and the following seven programs: ›› ›› ›› ›› ›› ›› ›› Shaft Circular motion Stretch Relaxation Shoulders Activation Vitalization665_029Foot massageMassage back areaMassage shoulder area26Foot massageDepending on equipment version, a foot massage is available for the first time. To be able to activate the foot massage function, the front passenger seat back must be moved from a reclining position to a folded forward position. The massage program offers two options allowing the soles of the feet to be massaged either by the linear application of pressure by massaging the reflex zones. For the foot massage there is a choice of: ›› Two programs (Wave, Stretch). ›› Three intensity levels. ›› Three foot sizes (S-M-L).665_028A17830827Surface heatingThe armrests in the door trims as well as the center armrests in the front and rear are heated surfaces. The one-piece front center armrest in is not heated. Only split front armrests are heated. All heated surfaces are deactivated and regulated through the seat heater.665_018Depending on trim level, three surface heating variants are available: ›› For the front seats only. ›› For the rear seats only. ›› Or for the front seats and rear seats.All surface heating variants are coupled directly to the seat heaters and cannot be operated independently of the seat heaters. The surface heating of the door armrests depends on what heating output is selected for the seat in question.The heating level for the center armrests in the front and rear of the vehicle is determined by whichever seat heating setting is higher in each row of seats. If, for example, the seat heater of the left, rear seat is set to level three and the seat heater of the right, rear seat is set to level one, the common armrest is switched to level three.28Foot heaterOverview of foot heater control system665_030Depending on equipment, the foot heater in the footrest can only be activated in the unfolded position and in the reclined position of the front passenger seat.It is operated through the Smart Remote Control unit and, like the seat heater and the seat ventilation system, is adjustable to three levels.Optional seat heating and ventilationThe seat heater and the seat ventilation system have three levels, which can be set at the front and rear control panels.29Workshop equipmentA/C service stationThe introduction of the new R744 refrigerant in the Audi A8 also sees the introduction of a new A/C service station for service. The previous A/C service stations cannot be used to service R744 refrigerant systems. Due to the new requirements for R744 regarding pressure and integrity, it was necessary to completely redesign the A/C service station.The following tasks can be carried out using the new A/C service station: ›› ›› ›› ›› ›› ›› Hose emptying Drainage Evacuation Filling Pressure testing Fresh oil and UV additive injectionThe multifunction steering wheel can be used for operation and menu navigation. There is an automatic mode and a manual mode in which operations can be selected individually.665_033The automatic "A/C service" mode includes the following operations: ›› ›› ›› ›› Self test Drainage Evacuation Filling665_034Note The refrigerant circuit cannot be flushed with the AC service station for R744. This must be done with one of the previously used AC service stations and the appropriate refrigrant (e.g. R1234yf or R134a).30Service connectionsThe caps covering the service connections of R744 air conditioning systems are snap fitting, and no longer screwed on. The snap fitting provides added safety since, unlike a threaded cap, refrigerant pressure cannot build up under the caps. This prevents the cap from becoming detached by itself due to high pressure, and reduces the risk of an accident. To avoid accidentally evacuating or refilling the A/C system with the wrong refrigerant when carrying out service work, the service connections and the service couplings are coded mechanically. This means that the connections for R134a, R1234yf and R744 differ in their geometry, such as diameter and connection length.665_01431AppendixeSelf-Study programsFor more information about the technology of the Audi A8, please refer to the following eSelf-Study programs.Self-Study Program 970133The Audi 3.0l V6 TFSI EA839 EngineAudi Occupant Protection SystemsSSP 970133 Audi Occupant Protection SystemseSelf Study Program 920173SSP 920173 The Audi 3.0l V6 TFSI EA839 EngineThe 2019 A8 Infotainment and Audi Connect SystemseSelf Study Program 990293The 2019 Audi A8 IntroductioneSelf-Study Program 990493SSP 990293 The 2019 Audi A8 Infotainment and Audi Connect SystemsSSP 990493 The 2019 Audi A8 IntroductionThe 2019 A8 Running Gear and Suspension SystemsSelf Study Program 960293The 2019 Audi A8 Electrics and ElectronicsSSP 960293 The 2019 A8 Running Gear and Suspension SytemseSelf-Study Program 970293SSP 970293 Audi A8 The 2019 Audi A8 Electrics and ElectronicsThe 2019 A8 Driver Assistance SystemsSelf Study Program 990393SSP 990393 The 2019 A8 Driver Assistance Systems32Knowledge assessmentAn On-Line Knowledge Assessment (exam) is Available for this eSelf-Study Program. The Knowledge Assessment is required for Certification credit. You can find this Knowledge Assessment at: www.accessaudi.comFrom the accessaudi.com Homepage: ›› Click on the “App Links” ›› Click on the “Academy site CRC” Click on the Course Catalog Search and select “980193 - The 2019 Audi A8 Climate Control Systems” Please submit any questions or inquiries via the Academy CRC Online Support Form which is located under the “Support” tab or the “Contact Us” tab of the Academy CRC.Thank you for reading this eSelf-Study Program and taking the assessment.33All rights reserved. Technical specifications subject to change without notice. Audi of America, LLC 2200 Ferdinand Porsche Drive Herndon, VA 20171980193