TECHNICAL DOCUMENTATION

SSP 079 Heating Auxiliary heater

PDFEN32 pages814 KB
SSP 079 Heating Auxiliary heater - PDF cover

This PDF is currently unavailable.

Read document text
ServiceAuxiliary heater79Service TrainingProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.� The auxiliary heater protects the engine and reduces its wear. Thanks to the auxiliary heater which preheats the engine, the pollutant emission is substantially reduced. On petrol engines, the production of hydrocarbons, nitrogen oxides and carbon monoxide decreases roughly by half.Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�2GB ContentsEinleitung Types of auxiliary heaters Combustion conditions Zusatzheizung in Škoda-Fahrzeugen Thermo Top V Function principle Venturi nozzle Control system Body of the combustion unit Operation Wiring diagram Electromagnetic valve N279 Fuel preheating Safety conditions Thermo Top C Fuel evaporator Function of the system Circulation pump Exhaust air fan Combustion chamber Exhaust system Operation 4 5 6 7 8 8 9 10 12 14 18 19 20 20 21 21 22 24 25 26 27 28You will find the notes for the assembly and disassembly, diagnostics as well as detailed user information in the workshop manuals, the diagnostic unit VAS 505x and in the onboard literature. The time for going to press was on the 12/2009. This brochure is not subject to an update.GBProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�3 IntroductionAuxiliary heaterThe auxiliary heating system allows us to set the optimal climate conditions in the vehicle interior using the heating or ventilation mode so that the vehicle interior is already heated, if necessary ventilated, before entering the vehicle. By using the auxiliary heating system, we prevent the frosting and fogging of the glass panes which would otherwise obstruct the driver's view. Wearing heavy winter clothing in the vehicle reduces the effectiveness of the seat belt - the play between the belt and the person's body increases because the seat belt does no longer fit tightly across the body. Wearing appropriate clothing in the pre-heated vehicle interior increases the protective effect of the seat belt and the responsiveness of the driver.Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�4GB Types of auxiliary heatersThe auxiliary heater (further referred to as AH) is part of a heating system which heats the inside of the vehicle, possibly the engine, regardless if the engine is running or not. The core of any such auxiliary heater is the combustion chamber, into which the combustion air is directed by means of the fan and where it mixes with the petrol and diesel fuel supplied from the fuel tank of the vehicle. The air-fuel mixture is ignited by a glow plug. The resulting combustion gases are diverted by means of the exhaust system of the AH.Auxiliary heaters are divided into two basic types:AUXILIARY HOT AIR HEATERAUXILIARY HOT WATER HEATERAuxiliary hot air heater The auxiliary hot air heater is used and installed primarily in cabins of lorries and machines, such as excavators, cranes, bulldozers or larger vans, ships' cabins etc. Auxiliary hot water heater The hot water heater is used mainly in passenger vehicles. Compared with hot-air systems, it offers the possibility of preheating the engine itself and the use of the ventilation distribution system.An advantage is the rapid heating of the individual area, the low consumption, a low noise level It has compact dimensions and is placed directly and the possibility of countless hours of operation in the engine compartment. (depending on the capacity of the battery). A disAmongst the main advantages is the aforemenadvantage is Protected the inability toCopying preheat the itself. tioned possibility to heat the unit to the desired by copyright. for private or unit commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability temperature before the actual start-up. In conwith respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.� nection herewith, the consumption as well as the emissions and not least the engine wear are reduced due to the already warmed-up engine.GB5 IntroductionCombustion conditionsThe auxiliary heater is a heating system that burns fuel. During this process, energy is released in the form of heat, which subsequently heats the liquid in the cooling circuit of the vehicle. The combustion process is determined by three basic factors: 1. Actual fuel – raw material which is converted into heat energy. The fuel from the fuel tank of the vehicle is injected into the combustion chamber of the auxiliary heater by means of the dosing pump of the AH. 2. Actual oxygen – enables the combustion during which the fuel is converted into energy.Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�The air supply is ensured by means of a fan which is a component of the body of the auxiliary heater.3. Required temperature – prerequisite to ensure the flash point. After activating the auxiliary heater, the electric current is conducted to the glow plug, which operates on the principle of electrical resistance and is heated by applying voltage.oxygenheatfuelSP79_116GB AH in Škoda vehiclesFor all the Škoda models produced in series, an auxiliary hot water heater Thermo Top V is provided as an optional equipment. As part of the range of Škoda Auto original accessories, an auxiliary heater can also be retrofitted in the vehicle, in this case a Thermo Top Cwater heating system. The range of original accessories also includes the Thermo Top C version with remote control.Series production Thermo Top V ŠkodaFabia ŠkodaFabia Combi ŠkodaRoomster ŠkodaOctavia I, II ŠkodaOctavia Combi I, II ŠkodaYeti ŠkodaSuperb I, II ŠkodaSuperb Combi I, II – – – Remote control – – – *** *** *** Original accessories Thermo Top C – – – Remote control – – –The table displays the options of auxiliary heating systems available for the individual vehicle models. The ŠkodaSuperb and Superb Combi models can be retrofitted with an optional Thermo Top V AH with remote control. *** For the ŠkodaOctavia I and II models and the ŠkodaYeti model which are equipped with the Thermo Top V system, a remote control can be bought in addition from the range of Škoda Auto original accessories.Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�GB7 Thermo Top VFunction principle of the auxiliary heaterThe fuel from the fuel tank of the vehicle (petrol or diesel) is transferred to the heating unit by means of a special pump. This is where the fuel and air mixes as it enters the combustion chamber via the venturi nozzle. The air is fed into the system by a fan, which is located in front of the nozzle, whereas the mouth of the fan is equipped with a silencer. The glow plug which extends into the combustion chamber is intended for the ignition of the mixture. The heat released during the combustion heats the exchanger, which in turn heats the water which flows through it. The exchanger is connected to the cooling circuit of the vehicle. The circulation of the liquid in the water circuit is ensured by the pump of the auxiliary heater. The combustion gases emitted during the firing process are diverted through the exhaust gas pipe which is fitted with a silencer. The control unit of the Thermo Top V system is a direct component of the heating unit. The temperature at the exchanger is monitored by two sensors - the temperature sensor and the overheat sensor.Venturi nozzleoutlet of heated waterCombustion air fantemperature sensor overheat sensorheat exchanger combustion air inlet fuel supply combustion gas exhaustSP79_88Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�GB Venturi nozzleOn the version Thermo Top V AH, the drawn-in air is led into the combustion chamber via a ceramic housing in the shape of a venturi nozzle. In such a way, the injection of the fuel is assisted by the suction effect.glow plugair supply fuel supply air supplySP79_9Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�SP79_10GB9 Thermo Top VControl system of the auxiliary heaterinstant heat button of the AHQ8V54 G18 V55Z66 G189 ** J364 Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.� W-Bus LED indicator light of the instant heat button of the AH V6R149N279 CAN Additional output signals, e.g. J13 – fresh air blower relay *SP79_16G18 G189 R149 W–Bus J364 Q8 V54 V55 Z66 V6 N279temperature sensor overheat sensor remote control receiver special databus for the connection R149 auxiliary heater control unit glow plug with flame monitor fuel dosing pump circulation pump heating element for preheating the fuel combustion air fan shut-off valve for the coolant, heating* **only for the model range ŠkodaSuperb I and II only for vehicles with diesel engines output signal input signal databus10GB Activation of the auxiliary heaterAfter activating the auxiliary heater, it is prepared for operation. The glow plug including the flame arrester Q8, the combustion air fan V6 and the circulation pump V55 are put into operation. The dosing pump V54 starts after 30 seconds and the combustion air fan V6 operation is suspended for 3 seconds. Subsequently, the combustion air fan V6 speed is increased in two ramps and increases again within 56 seconds to full load. After the stabilisation phase (constant speed) of 15 seconds, the combustion air fan V6 speed is again increased in a ramp within one cycle (50 seconds) to around the full load. After reaching full load during the fuel transfer, the glow plug including the flame arrester is deactivated Q8 and the combustion air fan V6 speed stabilises itself at full load. During the next 45 seconds, the glow plug including the flame arrester Q8, monitor the flame condition. Then begins the automatically controlled heating operation.Conditions for the activation:• A properly charged vehicle battery (a minimum voltage of 11.5 V is required for the faultless operation of the electrical components of the AH.) • Sufficient fuel (if too little fuel is present in the fuel tank - the fuel gauge is in the red field, the auxiliary heater control unit J364 does not activate the auxiliary heater.)Control of the auxiliary heaterThe auxiliary heater is designed to increase the temperature of the coolant. When the coolant temperature reaches 72°C, the auxiliary heater control unit J364 enables the auxiliary heater to switch to the energy saving part load operation. When the coolant temperature rises to 76.5°C, the auxiliary heater control unit J364 enables the auxiliary heater to enter a control idle period. If the coolant temperature drops during the control idle period to below 71°C within 900 seconds (15 mins), this causes the heating unit to perform a full load operation.In case of a no-flame condition or a flameout based on a malfunction, the fuel supply is Protected copyright. Copying for private or commercial purposes, in part or in whole, is not permitted stopped and theby auxiliary heater is deactivated, unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability Deactivation whereby the combustion air fan V6 runs down to Copyright with respect to the correctness of information in this document. by ŠKODA AUTO A. S.� of the auxiliary heater a standstill. After switching off the auxiliary heater manuIn case of a flameout during a normal combustion ally or after a running time of 60 minutes as well operation and if the system does not detect any as after the coolant temperature has reached malfunction, the flame automatically re-ignites. 85 °C, the combustion stops and the run-down commences. The circulation pump V55 and the combustion air fan V6 first continue operation to cool the auxiliary heater down (run-down) to be automatically switched off afterwards.GB11 Thermo Top VBody of the combustion unit - description and positioning in the vehicleinlet silencer Combustion air fanwater pumpSP79_20heat exchangeroutlet of heated waterexhaust gas silencercold water supplySP79_19Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�12GB The combustion gases emitted from the exhaust gas silencer are passed through the exhaust pipe located behind the front axle of the vehicle.SP79_18In the Škoda vehicles, the combustion unit of the Thermo Top V auxiliary heater is located in front of the wheel house of the front right wheel. The unit is attached to the lower longitudinal beam by means of a support bracket.Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�SP79_15GB13 Thermo Top VOperation of the auxiliary heaterThere are three ways of starting the Thermo Top V auxiliary heater: • Programming the auxiliary heater with the data display protocol via the multi-function display. • Starting the AH with the instant heat button on the dash panel of the heating and air conditioning system. • Using a separate remote control for the auxiliary heater.Programming the auxiliary heaterThe function of the auxiliary heater can be programmed using the multi-function display. In the menu Aux. heating the following basic set of entries are prepared: • Weekday • Running time • Mode Set the current weekday as well as the running time of the auxiliary heater in the range of 5–60 minutes and set the heating or ventilation mode using the entry mode. The weekday, hours and minute for the starting time of the AH can be set in the menu Aux. heating under the three pre-set times 1, 2 and 3.SP79_17The LED indicator light on the dash panel of the heating and air conditioning system notifies if the auxiliary heater is switched on or the activation period is programmed. The indicator light comes on when the auxiliary heater is switched on. If the activation period is programmed, the indicator light comes on for about ten seconds after switching off the ignition.14Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�GB Direct activation of the auxiliary heaterThe auxiliary heater can always be directly activated or deactivated using the button on the dash panel of the heating system (SP79_4), the Climatic (SP79_5) or Climatronic (SP79_6).SP79_4Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�ClimaticSP79_5ClimatronicSP79_6GB15 Thermo Top VRemote control of the auxiliary heaterconnection of the roof antennaThe Thermo Top V auxiliary heater with remote control can only be ordered as part of the optional equipment for the model range Superb. The receiver which receives the control signals from the remote control is located inside the vehicle body above the wheel house of the rear left wheel, it is connected to the auxiliary heater control unit via a wiring harness, whereby the roof antenna is also connected to the receiver.networking with the AH control unitremote control receiving unitSP79_12Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�SP79_13Positioning of the control unit for the remote control on the ŠkodaSuperb16GB Positioning of the control unit for the remote control on the ŠkodaSuperb CombiSP79_14A transmitter with a battery is located in the plastic housing of the miniature remote control. The remote control has an ON button for switching on, an OFF button for switching off and an LED signal diode for monitoring its condition (lights up green for 2 s = AH was activated; lights up red for 2 s = AH was deactivated). In addition, the diode indicates the battery charge level and the reception of the control signal from the remote control. The remote control cannot be used inside the vehicle. If the AH should be switched on using the remote control, we must respect a minimum distance of two metres from the vehicle in which the auxiliary heating to be operated is installed. The range of the transmitter with a charged battery is up to 600 m.antenna battery casing LED indicator light53 mmProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�SP79_1SP79_2GB17 Thermo Top VWiring diagramV2 J255 J533 J2856 3 4 J13G 18 1 J364G 189Q8 R149J301* J65*2 5 N24* V2*V54V55V6N279 ***Z66SP79_21V55 circulation pump 1 fuses V6 combustion air fan 2 battery N279 shut-off valve for the coolant, heating 3 instant heat button with indicator light J13 fresh air blower relay 4 antenna Z66 heating element for preheating the fuel (only 5 special databus 6 CAN databus - information system for diesel) V2 fresh air blower J301 control unit of the air conditioning system J255 Climatronic control unit J65 control unit of the heating system Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by Š KODA AUTO A. S. Š KODA AUTO A. S. does not guarantee or accept any liability J533 data bus diagnostic interface N24 pre-resistor for fresh air blower with overwith respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.� J285 control unit in dash panel insert with display heating limiter T16 diagnostic connection * only for the Climatic or heating system G18 temperature sensor ** only for vehicles with diesel engines Q8 glow plug with flame monitor *** except T-FSI engines and diesel engines J364 auxiliary heater control unit with DFS R149 remote control receiver V54 fuel dosing pump output signal input signal databus positive pole earth (ground)18GB Electromagnetic valve of the coolant N279After starting the auxiliary heater, the electromagnetic valve shuts off the flow of water to the engine and now the heat from the AH is only made available to the coolant flowing to the exchanger, which in turn heats the air directed into the interior of the vehicle. This valve is not used in an auxiliary heater in combination with TSI petrol engines (T-FSI) and diesel engines with a particle filter - DPF. On these engines, the auxiliary heater heats the water in the entire cooling circuit and thus the engine block as well.casing of the electromagnetic coilto engine (when AH is switched off)coolant supply from the auxiliary heater to exchanger with the fresh air blowerProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�SP79_24GB19 Thermo Top VPreheating of the fuelOn diesel engines, the AH Thermo Top V version is equipped with a heating element for preheating. The fuel is directly preheated by the heating element prior to injection into the combustion chamber, thus reducing the formation of smoke when starting the heater. The heating element is activated for approximately one minute after starting the AH.heating element Z66Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�SP79_25fuel supplySafety conditions for the use of the auxiliary heater• The auxiliary heater must not be used withina closed area! The AH produces combustion gases which could cause poisoning. Therefore, the vehicle must not be within a closed area, such as in the garage, when activating the AH. • When filling up with fuel, the auxiliary heater must always be switched off, otherwise there is a risk of fire! • When using the AH, you should not stand on a surface that could ignite easily from the hot exhaust gases of the auxiliary heater, for example, dry grass.20GB Thermo Top CFuel evaporatorThere is no venturi nozzle used on the Thermo Top C auxiliary heater (see page 9), the fuel is mixed with air in the evaporator. Other function principles of the auxiliary heater are identical to the Thermo Top V version.air supplyair supplyfuel supplyair supplySP79_23glow plug air supplySP79_22Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted GB unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�21 Thermo Top CFunction of the systemCombustion air fancombustion air ductcoolant outletfuel evaporatorcombustion air inletflueProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�water jacketcoolant inlet exhaust pipe fuel supply combustion chamber glow plugSP79_2622GB The Thermo Top C auxiliary heater can be retrofitted in the vehicle as part of the original accessories of Škoda Auto. Except for the use of the fuel evaporator, the heater unit is identical in terms of operation with the Thermo Top V version, but differs in the design of the unit.The combustion unit of the Thermo Top C auxiliary heater is installed in front of the wheel house of the front left wheel. In case the vehicle is equipped with a turbocharged engine, the compressed air cooling radiator is already fitted in this space, whereas the combustion unit is located on the right side of the vehicle. Always observe the notes of the assembly instruction which is included in the set of original accessories of the auxiliary heater.control unit Combustion air fanProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�water jacketCirculation pumpburner housingSP79_27GB23 Thermo Top CCirculation pumpIf the engine is switched off, the coolant circulation is ensured by the circulation pump of the auxiliary heater. It is directly activated by the AH control unit.iron coreelectromagnetic coilpermanent magnetfan wheel of the pumpProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�SP79_2824GB Combustion air fanThe air for the combustion is drawn in by the combustion air fan via the silencer and then passes through the air duct to the fuel evaporator and enters the combustion chamber.fan wheel of the fanmotor of the fanintake air silencer for the combustionair supply from the silencerProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�fan housingsilencer and filter elementair inletSP79_29GB25 Thermo Top Ccombustion chamberThe formation of the fuel-air mixture takes place in the combustion chamber. The following combustion takes place in the flu. The glow plug which extends into the combustion chamber ignites the fuel-air mixture in the activation phase. Another function of the glow plug is to monitor the temperature of the flame over the entire running time of the auxiliary heater.combustion air inlet coolant outlet fuel supplyDuring the heating phase, the mixture is ignited from the already hot walls of the combustion chamber.Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�glow plug coolant inlet combustion air inlet in the fuel evaporator combustion chamber exhaust pipeflueSP79_3026GB Exhaust systemThe heating unit is fitted with a separate exhaust system, which consists of the exhaust pipe and the silencer. The exhaust system directs the resulting exhaust gases independently from the exhaust management system of the vehicle. The length of the exhaust system is well defined and coordinated with the pulsating combustion within the heating unit. For safe operation, it is therefore required to adhere to the established length of the exhaust pipe.Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability exhaust pipe with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�SP79_31silencerGB27 Thermo Top COperationThe Thermo Top C auxiliary heater is equipped with a timer that allows the activation of the AH to be programmed. The clock makes it possible to store three activation periods, whereas only one can be activated each time. The system can also be supplemented by a remote control with Telestart transmitter T91. The receiver of the remote control is then located under the dashboard - to the left of the steering column.Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�SP79_3228GB NotesProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�GB29 NotesProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�30GB Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�GB31 Overview of the previously edited service training resourcesNo.Designation1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Mono-Motronic Central locking Vehicle alarm Working with wiring diagrams ŠKODA FELICIA Safety of the ŠKODA vehicles Principles of ABS - were not published ABS - FELICIA System for safe start-up with transponder Air conditioning in the vehicle Air conditioning FELICIA 1.6 engine - MPI 1AV Four-cylinder diesel engine Power-assisted steering ŠKODA OCTAVIA 1.9 ltr. TDI diesel engine ŠKODA OCTAVIA Convenience electronic system ŠKODA OCTAVIA Manual gearbox 02K, 02J 1.6 ltr. and 1.8 ltr. petrol engines Automatic gearbox - fundamentals Automatic gearbox 01M 1.9 ltr./50 kW SDI diesel engines, 1.9 ltr./81 kW TDI 1.8 ltr./110 kW and 1.8 ltr./92 kW petrol engines OCTAVIA, CAN BUS databus OCTAVIA - CLIMATRONIC OCTAVIA - safety of the vehicle OCTAVIA - 1.4 ltr./44 kW engine and gearbox 002 OCTAVIA - ESP - fundamentals, design, function OCTAVIA 4 x 4 - all-wheel drive 2.0 ltr. 85 kW and 88 kW petrol engines Radio navigation system - design and functions ŠKODA FABIA - technical information ŠKODA FABIA - electrical systems ŠKODA FABIA - electro-hydraulic power-assisted steering 1.4 ltr. - 16 V 55/74 kW petrol engines ŠKODA FABIA - 1.9 ltr. TDI Unit injection Manual gearbox 02T and 002 ŠkodaOctavia; model 2001 Euro-On-Board-Diagnosis Automatic gearbox 001 Six-speed gearbox 02M ŠkodaFabia - ESP Exhaust emissions Extended service intervals Three-cylinder petrol engines 1.2 ltr. ŠkodaSuperb; Presentation of the vehicle; part I ŠkodaSuperb; Presentation of the vehicle; part Il ŠkodaSuperb; 2.8 ltr./142 kW V6 petrol engine ŠkodaSuperb; 2.5 ltr./114 kW TDI V6 petrol engine ŠkodaSuperb; Automatic gearbox 01VNo.Designation51 2.0 ltr./85 kW petrol engine with balancing shafts and two-stage intake manifold 52 ŠkodaFabia; 1.4 ltr. TDI engine with unit injection system 53 ŠkodaOctavia; Presentation of the vehicle 54 ŠkodaOctavia; Electrical Components 55 FSI petrol engines; 2.0 ltr./110 kW and 1.6 ltr./85 kW 56 Automatic gearbox DSG-02E 57 Diesel engine; 2.0 ltr./103 kW TDI with pump-nozzle units, 2.0 ltr./100 kW TDI with pump-nozzle units 58 ŠkodaOctavia, Chassis and electromechanical power-assisted steering 59 ŠkodaOctavia RS, 2.0 ltr./147 kW FSI turbo engine 60 2.0 ltr./103 kW 2V TDI diesel engine; particle filter with additive 61 Radio navigation systems in the Škoda 62 ŠkodaRoomster; Vehicle presentation part l 63 ŠkodaRoomster; Vehicle presentation part ll 64 ŠkodaFabia II; Vehicle presentation part 65 ŠkodaSuperb II; Vehicle presentation part l 66 ŠkodaSuperb II; Vehicle presentation part ll 67 2.0 ltr./125 kW TDI diesel engine with Common Rail injection system 68 1.4 ltr./92 kW TSI petrol engine with turbocharger 69 3.6 ltr./191 kW FSI petrol engine 70 All-wheel drive with Haldex coupling of the lV. generation 71 ŠkodaYeti; Vehicle presentation part l 72 ŠkodaYeti; Vehicle presentation part ll 73 LPG system in Škoda vehicles 74 1.2 ltr./77 kW TSI petrol engine with turbocharger 75 Automatic 7-speed gearbox with double clutch 0AM 76 Greenline vehicles 77 Geometry 78 Passive safety 79 Additional heatingOnly for the internal use the network ŠKODA. with in respect to service the correctness of information in this document. Copyright by ŠKODA AUTO A. S.� All rights and technical modifications reserved. This paper was made out of S00.2002.79.20 E GB Technical status 12/2009 chlorine-free bleached cellulose. © ŠKODA AUTO a.s. http://portal.skoda-auto.comProtected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability79