TECHNICAL DOCUMENTATION

SSP 110 Refrigerant R1234yf forair conditioning systemsin ŠKODA AUTO vehicles

PDFEN44 pages2 MB
SSP 110 Refrigerant R1234yf forair conditioning systemsin ŠKODA AUTO vehicles - PDF cover

This PDF is currently unavailable.

Read document text
Refrigerant R1234yf for air conditioning systems in ŠKODA AUTO vehiclesProCarManuals.comSelf-study programmeŠKODA Service®110 ProCarManuals.com Table of contents1. Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 AC refrigerant-related measures arising from new emission legislation . . . . . . . . . . . . 2. Key AC principles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Glossary.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Refrigerant circulation in a closed AC circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. Refrigerants – overview.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 R12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 R134a. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 R1234yf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.1 Comparison - CFC/HFC/ HFO environmental impact . . . . . . . . . . . . . . . . . . . . . 3.3.2 Comparison R134a/R1234yf global warming potential .. . . . . . . . . . . . . . . . . . 3.3.3 Comparison - R134a/R1234yf properties.. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.4 R1234yf - reactions with metals and plastics.. . . . . . . . . . . . . . . . . . . . . . . . . 3.3.5 R1234yf - colour and odour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.6 Comparison R134a/R1234yf vapour pressure . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.6.1 R1234yf - temperature-dependent saturated vapour pressure . . . . . . . 3.3.7 R1234yf - flammability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.8 R1234yf - storage and handling safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. Refrigerant oil. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 AC oil – distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 AC oil – quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3 AC oil – type .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. Service ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6. Warning label for the AC cooling circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7. MQB inner heat exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8. AC system changes in connection with the transition to the new refrigerant - R1234yf . . 8.1 AC system changes in the ŠKODA Fabia and ŠKODA Rapid lines. . . . . . . . . . . . . . . . . . 8.2 MQB AC system changes in the ŠKODA Octavia and ŠKODA Superb lines. . . . . . . . . . . 8.3 AC system changes in the ŠKODA Yeti line.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.4 AC system changes in the ŠKODA Citigo line.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9. AC compressor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1 Types of compressors in use.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1.1 Table – AC compressors used in ŠKODA vehicles. . . . . . . . . . . . . . . . . . . . . . . . 9.1.2 AC compressor with inner pressure control valve and electromagnetic clutch. . 9.1.2.1 Electromagnetic clutch in the AC compressor.. . . . . . . . . . . . . . . . . . . . 9.1.3 Externally controlled AC compressor with inner electromagnetic control valve. . 10. AC evaporator.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11. AC condenser.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12. Service stations for AC systems with R1234yf.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.1 Service stations for R1234yf - characteristics.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.2 Service centre safety concept for R1234yf.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.3 AC service station VAS 581 00140.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.4 AC service station VAS 581 00341. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 7 7 8 10 . 10 . 10 . 10 . 11 . 11 . 12 . 13 . 13 . 13 . 14 . 15 . 15 . 16 . 17 . 17 . 17 18 . 19 . 21 22 24 26 28 30 32 32 32 33 34 34 36 37 38 38 39 40 . 41 . . . . .ProCarManuals.comGB3 ProCarManuals.comFor assembly, disassembly, repair and diagnostics instructions, as well as detailed user information see VAS diagnostics devices and safety sheets. Closing date – 5/2016. This Workbook is not subject to updates.SP110_004GB 1. Introduction1.1 AC refrigerant-related measures arising from new emission legislation The EU Directive 2006/40/EC relating to emissions from air conditioning systems in motor vehicles places new demands on refrigerants used in car air conditioning units. In response to this Directive, ŠKODA AUTO has been using a new refrigerant in its vehicles, R1234yf, since mid- 2016. The respective components of the air conditioning circuit need to be adapted to the new refrigerant, and this self-study material provides more details in this respect. Automotive air conditioning systems account for as much as 40% of all air conditioning systems worldwide. The use of this environmentally-friendly refrigerant in car air conditioning systems will substantially reduce greenhouse gas emissions.ProCarManuals.comGB5 ProCarManuals.com6GB 2. Basic air conditioning principles2.1 GlossaryBased on physical laws and principles, the car interior air conditioning system involves the use of a special chemical agent referred to as „refrigerant”. To make the car air conditioning principle easier to understand, the table below provides a list of key terms and definitions:HeatHeat is a type of energy. The unit of heat is joule (J). Heat can spread and can be accumulated. Heat exchange is a thermodynamic process in which heat is exchanged between two bodies of different temperatures. In any heat exchange process the warmer body gives some part of its inner energy to the colder body. The cooling principle is based on heat exchange. One of the ways of heat propagation, convection is based on streaming of materials of different temperatures. Streaming-based heat propagation is impossible with solid substances - it only occurs with fluids (liquids and gases). Chill is a lower level of heat. Generally, temperatures below the water freezing point are regarded as „chill“. Chill can be defined as a feeling of coldness that people feel when exposed to temperatures substantially below that of their own body. Boiling is a process through which a liquid (its whole volume) changes to a gas. The boiling temperature is different for each type of liquid, and also depends on the pressure above the liquid concerned - the higher the pressure, the higher the boiling temperature. Condensation is a process through which a gas changes to a liquid. Refrigerant – medium using which the heat exchange process is performed. Depending on the temperature and pressure, the refrigerant medium is in a gaseous or liquid state. When expanded, the refrigerant cools down. A gas that expands substantially after passing through an expansion valve cools down significantly.Heat exchangeProCarManuals.comConvectionChillBoilingCondensationRefrigerantCooling by expansionGB7 2.2 Refrigerant circulation in a closed air conditioning circuitThe air conditioning system is made up of four basic units: – Compressor – Condenser – Expansion valve – Evaporator These units are integrated in a closed circuit made up of two parts: – Low-pressure – High-pressureLo w p a er turem teAC compressor The compressor draws in the low-pressure, gaseous refrigerant. The refrigerant is compressed and taken by the compressor to the high-pressure part of the AC circuit. As the refrigerant is compressed, its temperature grows. Condenser The condenser is passed through by the high-pressure part of the AC circuit. This is where some of the heat is taken away from the compressed refrigerant that, so far, has been in a gaseous state. The heat is taken outside the car and is given to the ambient air that passes through the condenser. Expansion valve The high-pressure, liquid refrigerant goes through the expansion valve to the low-pressure part of the AC circuit. The refrigerant expands and changes its state from liquid to gas. As the refrigerant expands, its temperature falls down substantially. Evaporator The evaporator is passed through by the low-pressure part of the AC circuit. This is where the refrigerant receives heat from the fresh air going to the car‘s interior through the evaporator. This way the air that passes through the evaporator is cooled down, while the refrigerant is heated. The refrigerant leaves the evaporator in a gaseous state, and the compressor takes it back to the high-pressure part of the AC circuit.s ou e s e ga r a ssu n e t i pr an ow r e ,l ig f r a te e r stProCarManuals.comMechanically driven AC compressors ou se e g a ur a e ss n t i pr an h e r , hig ig re f r te tu re s t a ra peUsing the refrigerant, the air conditioning system performs a thermal circulation process during which heat is received from the car‘s cooled interior (at a low temperature and low pressure of the refrigerant, through the evaporator) and given to the space outside the car (at a higher temperature and high pressure of the refrigerant, through the condenser). In this process the refrigerant changes its state from liquid to gas and vice versa.Hi ghtem8GB EvaporatorWhen the recirculation is on, instead of drawing in and cooling down fresh air, the system cools down the air taken in from the car‘s interior.re tu ra pe s m te ou w se e Lo g a s ur a n es t i pr an w er lo ig te, a st re frProCarManuals.comExpansion valveli u r e a n e ss i t r an h p r e ig re g tu r i e, h f a r re a t pe st m te um i ed Mi qudSP110_1High-pressure part of the AC circuit Low-pressure part of the AC circuit CondenserGB9 3. Refrigerants – overviewGenerally, refrigerants are divided into three groups: – Naturally occurring substances (such as NH3 /ammonia/, CO2 , H2O) – Pure hydrocarbons (such as propane, isobutane) – Halogen hydrocarbons (CFC, HCFC, HFC and HFO refrigerants) In response to the high-efficiency requirement, halogen hydrocarbons are the most frequently used category of refrigerants in car air conditioning systems. However, the latest trends around environmentally-friendly mobile AC units also involve the use of carbon dioxide (CO2) as a completely natural refrigerant.3.1 R12Produced in the past, R12 is a refrigerant whose chemical composition is basically identical to that of CCl2F 2 (dichlorodifluoromethane). In the early 1990s it was proven that R12 (falling under the CFC group) damages the ozone layer, i.e. contributes to ozone hole formation. In 1995, the use of this substance in air conditioning systems was banned.ProCarManuals.com3.2 R134aCombining fluorine, carbon and hydrogen, R134a is a refrigerant whose chemical composition is basically identical to that of CH2FCF 3 (tetrafluoroethane). This product does not contain any atoms of chlorine - in contrast with R12 whose use was found unacceptable due to its high ozone damage potential. R134a is a CFC-free product with a zero ozone damage potential, but as a greenhouse gas it is considered to be environmentally unfriendly.3.3 R1234yfR 1234yf is a new HFO refrigerant whose chemical composition is basically identical to that of CF 3CF=CH2 (tetrafluoropropene). This product has been developed to replace R134a, the objective being to reduce greenhouse emissions.10GB 3.3.1 Comparison – CFC/HFC/HFO environmental impactCFC emissions; Damage the ozone layerNo CFC emissions; Greenhouse gas emissions; Causes global warmingNo CFC emissions; Low greenhouse gas emissionsCFC R12HFC R134aHFO R1234yfSP110_2Newly used also in ŠKODA AUTO air conditioning systems, R1234yf is substantially environmentally friendlier than its predecessor (R134a).ProCarManuals.com3.3.2 Comparison – R134a/R1234yf global warming potentialThe emissions of each gas that contributes to the greenhouse effect on our planet are defined as the „global warming potential” (GWP) - R1234yf´s GWP is 335 times lower than that of R134a (HFC). R1234yf´s GWP is low (GWP=4), i.e. the product generates substantially lower greenhouse gas emission levels than its predecessor, R134a. The new R1234yf therefore fully complies with EU 2006/40/EC under which the maximum GWP is 150 for refrigerants used in new types of vehicles (effective as of January 2011) and all new vehicles (effective as of 2017).1,430GWPGWP = 4 150 Directive EU 2006/40/EC R134a R1234yfSP110_3GB11 3.3.3 Comparison - R134a/R1234yf propertiesR134a Chemical name Chemical formula Recommended oil tetrafluoroethane CH2FCF 3 Polyalkylene glycol (PAG) (polyoester - POE) A1 - non-toxic, inflammable -26 °C 0 1,430 100 %R1234yf tetrafluoropropene CF 3CF=CH2 Polyalkylene glycol (PAG) developed for R1234yf (polyoester - POE) A2L - non-toxic, moderately flammable -29 °C 0 4 0.3 %ASHRAE classification Boiling point - 1 at ODP GWP GWP as a %share of R134a * ODP – ozone damage potential * GWP – global warming potentialProCarManuals.comR1234yf benefits Is designed specifically as a fill for mobile air conditioning systems. Features cooling-capacity and energy-efficiency levels comparable with those of R134a. Is suitable across all of the world´s climatic regions. Complies with global environmental standards. Its GWP (global warming potential) is 4, i. e. 99.7% lower than that of R134a. Has a zero ozone damage potential. Is non-toxic.12GB 3.3.4 reactions with metals and plastics– In its pure state, R1234yf is chemically stable; it does not eat away iron, aluminium and plastics developed and designed specifically for AC systems. – However, impurities in this refrigerant may eat away and damage cooling circuit components. – Unsuitable materials (such as seals and hoses not developed for the use of R1234yf and the applied refrigerant oil) may also be eaten away and damaged by a pure R1234yf or the refrigerant oil. – Contaminating the refrigerant with e.g. chlorine compounds or exposing it to ultraviolet light may lead to corrosion/destruction of metals and plastics developed and tested for use with this refrigerant and the respective refrigerant oil. That, as a result, may lead to blockages, leaks and sediments on the AC compressor piston.Warning! Some metals (such as dispersed aluminium, zinc, magnesium) may get corroded by R1234yf!ProCarManuals.com3.3.5 R1234yf – colour and odourR1234yf – colour In both gaseous and liquid state, this refrigerant is colourless like water. The gas is invisible, i.e. the only visible condition is that on the border between its gaseous and liquid states (surface level of the liquid in the vertical pipe of the filling cylinder or bubbles in the peep-hole). On a slide the R1234yf liquid may look milky. This turbidity is caused by the refrigerant oil, and is not a symptom of any defect. R1234yf – odour This refrigerant is almost odourless; a moderate ether-like odour may be detected in the event of a leak, depending on the ambient conditions.GB13 3.3.6 Comparison – R134a/R1234yf vapour pressureSaturated vapour – definition The result of heating a liquid in a closed container is saturated vapour. Generally, saturated vapour is vapour that is in thermodynamic equilibrium with a liquid of the same temperature and pressure. In this dynamic equilibrium, the evaporated substance is exactly replaced with a condensed one. The number of molecules leaving the surface level of the liquid is equal to the number of molecules that get back to the liquid after the condensation. As the temperature of the liquid increases, so do the density and pressure of its saturated vapour.3.5 3 Pressure (MPa) 2.5 2 1.5 1 0.5 0 -40SP110_4ProCarManuals.com-20020406080100Temperature (°C)R1234yf – saturated vapour pressure R134a – saturated vapour pressureThe pressure curves for R1234yf and R134a are very similar across an extensive range of temperatures, i.e. the vapour pressure dependent on temperature is not exactly a parameter to be used to identify each of these two refrigerants. Such differentiation (identification) is only possible by means of sensors analysing the chemical composition of the refrigerant(s).14GB 3.3.6.1  R1234yf – temperature-dependent saturated vapour pressureTemperature (°C) -40 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35Pressure (bar) -0.40 -0.01 0.12 0.50 0.83 1.21 1.65 2.15 2.72 3.36 4.09 4.90 5.81 6.82 7.93 9.17 10.52 12.01 13.64 15.41 17.35 19.46 21.75 24.24 26.94 29.09ProCarManuals.com40 45 50 55 60 65 70 75 80 85 903.3.7 R1234yf – flammabilityIn some concentrations, R1234yf is flammable in ambient air. When in a flame or in contact with a hot surface, this refrigerant disintegrates while releasing toxic products. Further, R1234yf gets disintegrated when exposed to ultraviolet radiation (which is part of sunlight).GB15 3.3.8  R1234yf – storage and handling safetyR1234yf storage Considering its flammability, R1234yf has to be stored separately, in compliance with the legislation governing the storage of flammable substances. – Must not be stored in the same area with oils and other lubricants. – The maximum ambient temperature for R1234yf storage is +50°C. – Must not be stored in the sun and near sources of heat. – May only be stored in original bottles (cylinders) used by the manufacturer/distributor. – Only the filler produced specifically for R1234yf is allowed – non-explosive design under ATEX 95. – Only original hoses designed for R1234yf are allowed. – To prevent leaks, use an electronic detector, a detection agent filled into the circuit by the vehicle manufacturer or a bubble spray.R1234yf storage in high-pressure cylinders – Under the EU legislation involving flammable substances, high-pressure cylinders have to be painted white (collar red). The filler valve is fitted with a left-hand thread (ACME). – Since April 2014, the cylinders are supplied with Thread W 21, 8L (EU) used for flammable gases. – High-pressure cylinder size: 5 and 10 kg. – The high-pressure cylinder is fitted with a check-valve to prevent repeated filling outside the filling line.ProCarManuals.comRefrigerant handling – servicing work Please mind the following when exhausting or filling the R1234yf into the cooling circuit: – Compared with R134a, R1234yf is expensive - make sure to eliminate any leaks, e. g. by emptying the hoses properly. – No smoking/naked fire! – If you need to check the circuit for tightness or perform a circuit pressure check, always use dry nitrogen. Use of air poses a risk of explosion - residual refrigerant and air vapours produce an explosive blend in the AC circuit. – AC circuit vacuum-pumping should be done really thoroughly, and the achieved vacuum level should not change for at least 30 minutes. – T he R1234yf pre-filling and the tightness check should take at least 10-20 minutes. This operation is usually done automatically, without the staff‘s intervention. – When refilling the circuit, use the correct quantities of both R1234yf and the PAG oil (R1234yf-specific). Compared with R134a, topping up this refrigerant or using a new fill takes 40–50 minutes longer.Compared with R134a, topping up this refrigerant or using a new fill takes 40 - 50 minutes longer.16GB 4. Refrigerant oilAC compressor lubrication The refrigerant oil is used for lubricating the moving parts of the compressor. This oil has to be compatible with the refrigerant, because, to some extent, these two substances circulate together in the AC circuit.4.1 AC oil – distributionThe refrigerant oil blends with the refrigerant to permanently circulate in the AC cooling circuit. This way the oil is distributed throughout the AC circuit, as shown in the chart below.Chart: refrigerant oil distribution in the AC system – shares (in percent)CondenserProCarManuals.com10 %EvaporatorAC compressor20 % 50 %10 %SP110_1310 %DryerHoses4.2 AC oil – quantityThe quantity of oil varies, depending on the type of the AC system/AC compressor.GB17 4.3 AC oil – typeThe type of AC oil depends on the refrigerant applied. The older refrigerant, R134a, is blended with a synthetic PAG oil (polyalkylene glycol). The oil used with the new refrigerant, R1234yf, is a PAG enriched with special additives.The compressor designed for R1234yf cannot be substituted for by one intended for R134a. The PAG oils developed for R134a and R1234yf are different. The PAG oil for R134a cannot be used in an AC system using R1234yf.PAG oil properties High blendability with the refrigerant Good lubrication properties Does not contain acids Strongly hydroscopic (absorbs water) Not blendable with other types of oilProCarManuals.comNot blendable with other types of oilThe PAG oil is hydroscopic - to protect the refrigerant oil from humidity, reclose open containers immediately and keep them closed.To avoid AC compressor damage, never start the engine right after vacuum-pumping the cooling circuit.18GB 5. Service portsThe car air conditioning circuit is fitted with a couple of service ports, one for servicing the high-pressure part of the cooling circuit and one for the low-pressure part. Each of the service ports has a different diameter to prevent confusion. The launch of the new refrigerant, R1234yf, brought about the need to ensure that the service ports (high-pressure and low-pressure parts) as well as the respective refrigerants (R134a and R1234yf) are not confused. That is why the two service ports designed for the new refrigerant (R1234yf) are different from those used for the old refrigerant (R134a).The table below provides key parameters of the four impossible-to-confuse service ports:Service port dimensionsService port, R134aService port, R1234yfHigh-pressure sideLow-pressure side 13.0 mm 11.0 mm 6.15 mm 9.16 mm 6.1 – 7.1 mmHigh-pressure side 17.0 mm 13.0 mm 9.0 mm 12.5 mm 8.3 – 9.3 mmLow-pressure side 14.0 mm 12.0 mm 4.75 mm 7.2 mm 8.3 – 9.3 mmProCarManuals.comOuter diameter (D1) Outer diameter (D2) Recess (L1) Recess (L2) Valve installation position; not active (C)16.0 mm 14.0 mm 4.6 mm 8.16 mm 6.1 – 7.1 mmAC circuit service port – cross sectionCvalve unitD2D1L1 L2SP110_9GB19 Service port caps The service ports come with plastic caps - these caps are fitted with special seals. For ease of survey and to differentiate between the respective refrigerants, the caps of the AC service ports for R134a are black; the caps of the AC service ports for R1234yf are grey.12ProCarManuals.comSP110_111 – Service port in the low-pressure AC circuit with R134a 2 – Service port in the high-pressure AC circuit with R134a34SP110_103 – Service port in the low-pressure AC circuit with R1234yf 4 – Service port in the high-pressure AC circuit with R1234yf20GB 6. AC cooling circuit warning labelThe warning label provides information about the type of the applied refrigerant, the manufacturer-supplied quantity of the refrigerant and the type of the refrigerant oil applied. The symbols on the warning label highlight dangers involved in handling the refrigerant and performing work on the cooling circuit.Refrigerant appliedDanger warning symbolsProCarManuals.comRefrigerant appliedRefrigerant quantityType of oilThe warning label for the AC cooling circuit is located on the cover of the space between the radiator mask and the front wall; the label is visible after lifting the bonnet.The label may also refer to standards, such as SAE, ISO, etc. SAE J639 – provides safety instructions for passenger vehicle AC systems. SAE J842 – describes the use of components and materials approved for R1234yf. SAE J2845 –  s tates that repairs and maintenance of AC cooling circuits can be performed exclusively by properly trained and certified persons.GB21 7. MQB inner heat exchangerIn connection with the Group‘s MQB platform, AC systems in ŠKODA vehicles are fitted with an inner heat exchanger designed to increase the efficiency of the AC circuit. Taking the form of a double-shell duralumin tube, the inner heat exchanger features an inlet to and an outlet from the AC circuit. Using the outer cavity of the heat exchanger (between the inner and outer shells), the highpressure liquid refrigerant goes to the evaporator that is cooled down by the low-pressure gaseous refrigerant discharged from the evaporator through the inner cavity of the heat exchanger.Inner heat exchanger – cross sectionProCarManuals.comHigh-pressure refrigerant (liquid state, medium temperature) taken to the expansion valve and evaporatorInner shellSP110_5Low-pressure refrigerant (gaseous state, low temperature) taken from the evaporator to the AC compressorOuter shellHigh-pressure pipe from the condenser Low-pressure pipe to the AC compressorHigh-pressure pipe to the expansion valve and then to the evaporator Low-pressure pipe from the evaporatorSP110_12Inner heat exchanger – ŠKODA Octavia III22GB ProCarManuals.comGBNotes:23 8.  Changes made to AC systems in connection with the transition to the new refrigerant, R1234yfThe AC circuit technology has been adapted for the new refrigerant (R1234yf) - see the description for each ŠKODA model line. Across all model lines, the rubber parts of the AC piping have been replaced with new pipes resistant to the new refrigerant, i.e. R1234yf.8.1  AC system changes in the ŠKODA Fabia and ŠKODA Rapid linesComparison – AC circuit design for R134a/R1234yf: – Redesigned, robust flange at the expansion valve and evaporator for R1234yf – Different service valves for R134a and R1234yf – Different compressors for R134a and R1234yf Both AC system versions come with the same condenser and the same anchoring elements.ProCarManuals.comIdentical body-anchoring element for R134a/R1234yfIdentical body beam-anchoring element for R134a/R1234yfThe refrigerant quantities in the two AC circuits are different, because the compressor in each of the systems is different and so are the hose routes. Quantity of R134a: 475 g Quantity of R1234yf: 450 gDifferent compressors for R134a/R1234yf C circuit A piping with R134a  C circuit A piping with R1234yf24GB Flange for the expansion valve and evaporator for R134aRobust flange for the expansion valve and evaporator for R1234yfDifferent service valves for R134a/R1234yf in the low-pressure part of the AC circuitProCarManuals.comDifferent service valves for R134a/R1234yf in the high-pressure part of the AC circuitSP110_14Identical condenser for R134a/R1234yfGB25 8.2  MQB AC system changes in the ŠKODA Octavia and ŠKODA Superb linesComparison – AC circuit design for R134a/R1234yf: – Redesigned, robust flanges in the inner heat exchanger for R1234yf – Different service valves for R134a and R1234yf – Different compressors for R134a and R1234yf Both AC system versions come with the same condenser and the same anchoring elements.Inner heat exchanger - IWTDifferent service valves for R134a/R1234yf in the low-pressure part of the AC circuit Robust flange for the expansion valve and evaporator for R1234yfProCarManuals.comIdentical body-anchoring element for R134a/R1234yfIdentical body beam-anchoring element for R134a/R1234yfThe refrigerant quantities in the two AC circuits are different, because the compressor in each of the systems is different and so are the hose routes. Quantity of R134a: 500 g Quantity of R1234yf: 460 gDifferent compressors for R134a/R1234yf  C circuit A piping with R134a  C circuit A piping with R1234yf26GB Flange for the expansion valve and evaporator for R134aRobust flange for the expansion valve and evaporator for R1234yfProCarManuals.comDifferent service valves for R134a/R1234yf in the high-pressure part of the AC circuitSP110_15Identical condenser for R134a/R1234yfGB27 8.3  AC system changes in the ŠKODA Yeti lineComparison - AC circuit design for R134a/R1234yf: – E xpansion valve for R1234yf – different location plus thermal shield – Different service valves for R134a and R1234yf – Different compressors for R134a and R1234yf Both AC system versions come with the same condenser and the same anchoring elements.Different expansion valves for R134a/R1234yfProCarManuals.comEvaporatorDifferent service valves for R134a/R1234yf in the low-pressure part of the AC circuitDifferent compressors for R134a/R1234yf C circuit A piping with R134a  C circuit A piping with R1234yf28GB Thermal shield for R1234yf (version without additional heating)Thermal shield for R1234yf (version with additional heating)ProCarManuals.comDifferent service valves for R134a/R1234yf in the high-pressure part of the AC circuitSP110_16Identical condenser for R134a/R1234yfGB29 8.4 A  C system changes in the ŠKODA Citigo lineComparison – AC circuit design for R134a/R1234yf: – Different service valves for R134a and R1234yf – Different compressors for R134a and R1234yf Both AC system versions come with the same condenser and the same anchoring elements.Different service valves for R134a/R1234yf in the low-pressure part of the AC circuitProCarManuals.comDifferent compressors for R134a/R1234yf C circuit A piping with R134a  C circuit A piping with R1234yf30GB Different service valves for R134a/R1234yf in the high-pressure part of the AC circuitProCarManuals.comSP110_17Identical condenser for R134a/R1234yfGB31 9. AC compressorCompressor The AC compressor draws in the refrigerant gas from the evaporator to compress it and take it to the condenser. Compression process The compressor draws the gaseous refrigerant from the evaporator, using the low-pressure branch of the AC circuit. The gaseous state of the refrigerant is important for the compressor, because in the liquid state the refrigerant cannot be compressed (and would damage the compressor). The AC compressor compresses the refrigerant and transports it (in the form of hot gas) to the condenser, using the high-pressure branch of the AC system. The compressor thus acts as an interface between the low-pressure and high-pressure branches. To lubricate the compressor, the refrigerant circulation system is filled with special oil (see page 17 of this workbook). Compressor performance control With no control valve in place, the performance of the compressor fully depends on the engine speed, i.e. the number of its revolutions. As the engine revs change, so does the filling of the evaporator and the cooling performance. To make the evaporator filling smooth, modern compressors are fitted with control valves. With the compressorcontrol capability in place the refrigerant pressure downstream of the compressor is stable despite variable heat transmission levels and engine revs.ProCarManuals.com9.1 Compressor types in useAs at the closing date for this Workbook, ŠKODA vehicles are fitted with the AC compressors specified in the table below. These compressors are differentiated as follows: – Compressors for R134a and compressors for R1234yf. – AC compressors with inner pressure control valve and electromagnetic clutch for connection with the engine. – Externally controlled AC compressors with inner electromagnetic control valve.9.1.1 Table – AC compressors used in ŠKODA vehiclesCompressor volume for R134a ŠKODA Fabia ŠKODA Rapid ŠKODA Octavia ŠKODA Superb ŠKODA Superb GreenLine ŠKODA Yeti ŠKODA Citigo137.2 cm3 /140.3 cm3Compressor volume for137.2 cm3 /140.3 cm3NumElectromagnetic ber of control valve pistons 6 6 6 6 / 7* 6Pressure control valveElectromagnetic clutch137.2 cm3 /140.3 cm3137.2 cm3 /140.3 cm3137.2 cm3 /140.3 cm3 137.2 cm3 /140.3 cm3 163.0 cm3 */171.4 cm3* 90 cm3137.2 cm3 /140.3 cm3137.2 cm3 /140.3 cm3 90 cm3* Note: These compressors are used in ŠKODA Yetis produced for hot countries.32GB 9.1.2 A  C compressor with inner pressure control valve and electromagnetic clutchThe ŠKODA Citigo is fitted with a 90 cm3 compressor with a directly integrated pressure control valve. The stroke and therefore the quantity of the transported refrigerant are determined by this pressure control valve. The ratio between the pressure inside the compressor and the low pressure of the refrigerant control the piston stroke, and also determines the required cooling level.drum with variable transverse positioning springsliding block pressure control valveProCarManuals.comcalibrated throttle borehigh pressure drive shaft low pressureSP110_21piston bottompistonpressure in the chamber drive hubThe drum is positioned longitudinally in the sliding block. The slanting position of the drum and therefore also the drive hub determine the piston stroke and therefore also the performance. The compressor drum angle depends on the pressure in the chamber and therefore also on the pressure ratios in front of and behind the piston, and is controlled by springs in front of and behind the drum. The pressure in the chamber is influenced by high and low pressure at the control valve and by the calibrated throttle bore.GB33 9.1.2.1 Electromagnetic clutch of the AC compressorThe AC compressor with an inner pressure control valve is connected to the engine by which it is driven, using an electromagnetic clutch. The electromagnetic clutch connects the compressor to the engine when the air conditioning is switched on. When the air conditioning is switched off, the electromagnetic clutch disconnects the compressor from the engine drive.Pulley for the groove belt to transmit torque from the engine through the electromagnetic clutch to the compressor drive shaftLow-pressure side of the compressor (from the evaporator)High-pressure side of the compressor (to the condenser)ProCarManuals.comSP110_20ŠKODA Citigo AC compressor with pressure control valve and electromagnetic clutch9.1.3 E  xternally controlled AC compressor with inner electromagnetic control valveThe modern design of AC compressors with an inner electromagnetic control valve makes it possible to smoothly control the compressor´s performance using the AC control unit. The torque from the engine is permanently transmitted to the compressor drive shaft, i.e. the compressor´s performance is fully controlled by the AC control unit, using the electromagnetic control valve.Electromagnetic control valvePressure in the crankcaseValve tappetHigh pressurePressure-sensitive elementSP110_20Intake pressureChart: AC compressor – electromagnetic control valve34GB Function principle This is a piston compressor with smooth intake-pressure control. The uncontrolled intake pressure is pre-set by an electronic control valve. The control valve is activated by the AC control unit, and this activation is controlled depending on the values set on the AC panel, the outside temperature, the high-pressure part of the AC and the required evaporator temperature.SP110_22ProCarManuals.comBalanced pressure in the system Compressor in the basic position – minimum piston stroke, the engine torque is permanently transmitted to the compressor drive shaftSP110_23 igh pressure H Intake pressure  Crankcase pressure  Compressor in the working position – medium piston stroke, the engine torque is permanently transmitted to the compressor drive shaftGB35 10. AC evaporatorDescription – evaporator function The liquid refrigerant is evaporated in the labyrinth of the evaporator tube that goes through a lamella grid. When the air conditioning is on, heat is taken away from the air that flows through the evaporator lamellas to the car´s interior – the air is cooled. The refrigerant evaporates and, together with the absorbed heat, is drawn in by the AC compressor. When the air conditioning is on, the air condenses on the evaporator walls. The condensate is taken outside the car, using a discharge aperture. The absolute air humidity inside the car is thus reduced. The evaporator therefore ensures that the air that flows to the passenger compartment is cooled, as well as dried up and cleaned.Cooled air taken to the car´s interiorEv a p or a torbod yProCarManuals.comRefrigerant outletRefrigerant inletSP110_26Warm outside (ambient) air36GB 11. AC condenserCondenser function principle The condenser takes away heat from the compressor-compressed refrigerant gas to the ambient air. The refrigerant gas condenses to liquid. In front of the condenser is a ventilator cooler of sufficient power for proper condenser functionality.Warmed-up airProCarManuals.comHot refrigerant in gaseous stateLiquid refrigerantSP110_25Ambient airIn the condenser the hot refrigerant (flowing from the compressor in gaseous state) is cooled down by the flowing ambient air as a result of which it condenses at the inlet to the condenser and becomes liquid again.GB37 12. S  ervice stations for AC systems with R1234yfAs at the closing date for this Workbook, two service stations were designed and approved for AC systems in ŠKODA vehicles using R1234yf: – VAS 581 001 – VAS 581 003 These AC service stations meet the stringent requirements for R1234yf handling to guarantee maximum operational safety.12.1. Service stations for R1234yf – characteristicsUse of special parts for each type of refrigerant The chemical properties of R134a and R1234yf are different. New service-station hoses, seals and pressure gauges have therefore been developed for the new refrigerant (R1234yf).ProCarManuals.comClear identification of service stations Service sites will now use two different types of AC service stations, which is why the stations will be identified clearly and visibly. Impossible-to-confuse service ports with a safety ventilation system The service ports on new R1234yf stations are different from those on R134a stations to prevent confusion (use of a station designed for a different refrigerant). Moreover, the service ports on R1234yf stations feature a safety ventilation system to ensure that the refrigerant does not leak from the air conditioning system even when the service valve in the vehicle is leaky Integrated refrigerant analysis process R1234yf reacts highly sensitively to contaminations by other refrigerants, and units that analyse and check its purity levels are therefore an essential part of the system. The integration of this analysis to the stations saves working time and increases safety, because it is always performed automatically, thus preventing contamination of the service station by an incorrect or contaminated refrigerant. Delayed activation R1234yf is flammable under certain circumstances, which is why after switching the device on the ventilation system is automatically activated to run independently for about 30 seconds and only then the station is connected to the power supply, to guarantee that no flammable blends are present inside the station upon activation of the respective electronics.38GB AC cleaning The system can be rinsed with the refrigerant, using a rinse set. The number of rinse cycles for each AC service station is set by the respective instructions for use. Each cycle requires approximately 3 kg of the refrigerant that is then drained. If the sufficient refrigerant quantity is not available, the process stops automatically. Connection for external refrigerant draining If an incorrect or contaminated refrigerant is detected during the refrigerant analysis, the AC system has to be cleaned (drained) – the refrigerant is drained to an external container with dry ice (VAS 581 007).12.2 Service-centre safety concept for R1234yfCompliance with the following requirements eliminates the potential for creating an explosive atmosphere: – Non-stop ventilation inside the service station (no refrigerant must cumulate, even in case of the smallest of leaks). – Only the ventilator is activated after switching the service station on - the other electronics are connected to the power supply about 30 seconds later. – The service station automatically and regularly checks the system for inside leaks. – T he service ports for connecting the device to the vehicle´s AC circuit give off an acoustic alert if the vehicle´s service valve is leaky. – The internal-analysis function prevents the system from drawing in an incorrect or contaminated refrigerant. – T he service station is fitted with an intelligent cooling circuit leak control system (based on vacuum and overpressure).ProCarManuals.comThe automatic check of the station for inside leaks takes about 20 minutes and is performed whenever the station is switched on.GB39 12.3 AC service station VAS 581 001VAS 581 001 AC service station with an integrated rinse system and a special refrigerant analysis system The system is controlled using a big keyboard and self-explaining navigation in the menu. The unit features delayed-activation and external-ventilation systems. The VAS 581 001 service station regularly performs automatic leak tests to ensure that even small leaks that may occur inside the unit are detected.Technical data – Controlled through a keyboard with function keys – Alternate use of PAG / POE oils – Fully automatic refrigerant analysis unit – 3.0 m service hose with couplings compliant with SAE J2888 – Highly efficient refrigerant recycling (99.9 %) – Refrigerant filling accuracy (+/- 15 g) - Oil and UV oil filling accuracy (+/- 2 g) using an electronic scale – Robust weighing technology, no calibration necessary – Special eight-bearing weighing technology – Automatic refrigerant leak detection – Integrated refrigerant fill-and-drain control – Heated 16 kg refrigerant tank for quick filling – Individual fill-quantity database – Fully automatic process control – Automatic safety test before starting the work – Dual electric ventilation for quick air exchange – Automatic leak detection – Automatic discharge of gases that cannot be condensed – Automatic device maintenance control – Thermo printer – Nominal voltage 220/240 V – 50/60 Hz – Dimensions: 1,300 x 560 x 650 mm – Weight: 110 kgProCarManuals.comSP110_19VAS 581 00140GB 12.4 AC service station VAS 581 003VAS 581 003 service station with an integrated rinse system and a special refrigerant analysis system The system is controlled using an intuitive, self-explaining menu. Instructions for use are displayed for each control action. The refrigerant, oil and UV oil are filled with high accuracy, using an electronic scale. Each AC maintenance process performed can also be stored in a PC, using an integrated SD card. Service data are stored in an internal database.Technical data – 5.7” VGA colour display, TFT 320 x 240 pixels – Controlled through a keyboard with function keys – Alternate use of PAG / POE oils – Impossible-to-confuse identification of oil and UV containers – 1 hermetically closed oil container – 1 hermetically closed UV oil container – 1 waste oil container – Fully automatic refrigerant analysis unit – 2.50 m service hose with couplings compliant with SAE J2888 – Highly efficient refrigerant recycling: 98% – Refrigerant filling accuracy (+/- 15 g) – Oil and UV oil filling accuracy (+/- 2 g) using an electronic scale – Control for one and more rinse operations – Heated 20 kg refrigerant tank for quick filling – Individual fill quantity database – Fully automatic process control with status indication – Automatic safety test with self-diagnostics – Dual electric ventilation for quick air exchange – Automatic leak detection – Tilting sensor for accurate results in horizontal position – Automatic discharge of gases that cannot be condensed – Automatic device maintenance control – Two-stage vacuum pump – Thermo printer – SD card slot for data storage and updates – Nominal voltage 230 V / 50 Hz, 800 Watt – Dimensions: 1,270 x 790 x 750 mm – Weight: 115.50 kgProCarManuals.comSP110_18VAS 581 003GB41 ProCarManuals.com42Notes:GB ProCarManuals.com Overview of Hitherto Issued Workshop Teaching AidsNo. Name 1 Mono-Motronic 2 Central Locking 3 Car Alarm Equipment 4 Work with Wiring Diagrams 5 ŠKODA FELICIA 6 ŠKODA Car Safety 7 ABS - Basics - not issued 8 ABS - FELICIA 9 Starting Protection Device with Transponder 10 Air Conditioning in Car 11 FELICIA Air Conditioning 12 1.6 - MPI 1AV Engine 13 Four-Cylinder Compression Ignition Engine 14 Power Steering 15 ŠKODA OCTAVIA 16 1.9 l TDI Compression Ignition Engine 17 ŠKODA OCTAVIA Comfort Electronics System 18 ŠKODA OCTAVIA 02K, 02J Mech. Gearbox 19 1.6 l and 1.8 l Gasoline Engines 20 Automatic Gearbox - Basics 21 01M Automatic Gearbox 2 2  1.9 l/50 kW SDI, 1.9 l/81 kW TDI Compression Ignition Engines 23 1.8 l/110 kW and 1.8 l/92 kW Gasoline Engines 24 OCTAVIA, CAN-BUS Data Bus 2 5 OCTAVIA - CLIMATRONIC 26 OCTAVIA - Vehicle Safety 2 7 OCTAVIA - 1.4 l/44 kW Engine and 002 Gearbox 28 OCTAVIA - ESP - Basics, Design, Function 2 9 OCTAVIA 4 x 4 - All-Wheel Drive 30 2.0 l 85 kW and 88 kW Gasoline Engines 31 Radio Navigation System - Design and Function 32 ŠKODA FABIA - Technical Information 33 ŠKODA FABIA - Electrical Devices 3 4 ŠKODA FABIA - Electrohydraulic Power Steering 35 1.4 l - 16 V 55/74 kW Gasoline Engines 36 ŠKODA FABIA - 1.9 l TDI Pump-Nozzle 37 02T and 002 Mechanical Gearbox 38 ŠKODAOctavia; Model 2001 39 Euro-On-Board-Diagnose 4 0 001 Automatic Gearbox 41 02M Six-Speed Gearbox 4 2 ŠKODA Fabia - ESP 43 Emissions in Exhaust Gases 4 4 Extended Service Intervals 45 1.2 l Three-Cylinder Spark-Ignition Engines 4 6 ŠKODA Superb; Presentation of the Vehicle, Part I 47 ŠKODA Superb; Presentation of the Vehicle, Part II 4 8 ŠKODA Superb; V6 2.8 l/142 kW Spark-Ignition Engine 49  ŠKODA Superb; V6 2.5 l/114 kW TDI Compression Ignition Engine 50 ŠKODA Superb; 01V Automatic Gearbox 51  2.0 l/85 kW Spark-Ignition Engine with Balancing Shafts and 2-Stage Intake Pipe 52  ŠKODA Fabia; 1.4 l TDI Engine with Pump-Nozzle Injection System 53 ŠKODA Octavia; Presentation of the Vehicle 54 ŠKODA Octavia; Electrical Components 55 FSI Spark-Ignition Engines; 2.0 l/110 kW and 1.6 l/85 kW 56 DSG-02E Automatic Gearbox 57   Compression Ignition Engine; 2.0 l/103 kW TDI with Pump-Nozzle Units, 2.0 l/100 kW TDI with Pump-Nozzle Units No. Name 58  ŠKODA Octavia, Chassis and Electromechanical Power Steering 59 ŠKODA Octavia RS, Engine 2.0 l/147 kW FSI Turbo 60  2.0 l/103 kW 2V TDI Compression Ignition Engine; Diesel Particulate Filter with Additive 61 Radio Navigation Systems in ŠKODA Cars 62 ŠKODA Roomster; Presentation of the Vehicle, Part I 63 ŠKODA Roomster; Presentation of the Vehicle, Part II 64 ŠKODA Fabia II; Presentation of the Vehicle 65 ŠKODA Superb II; Presentation of the Vehicle, Part I 66 ŠKODA Superb II; Presentation of the Vehicle, Part II 67  Compression Ignition Engine; 2.0 l/125 kW TDI with Common Rail Injection System 68  1.4 l/92 kW TSI Spark-Ignition Engine, Turbo Charged 69 3.6 l/191 kW FSI Spark-Ignition Engine 70 All-Wheel Drive with Generation IV Haldex Clutch 71 ŠKODA Yeti; Presentation of the Vehicle, Part I 72 ŠKODA Yeti; Presentation of the Vehicle, Part II 73 LPG System in ŠKODA Cars 74  1.2 l/77 kW TSI Spark-Ignition Engine, Turbo Charged 75  7-Speed Automatically Controlled Gearbox with 0AM Double Clutch 76 Green-Line Cars 77 Geometry 78 Passive Safety 79 Independent Heating 80  Compression Ignition Engines 2.0 l; 1.6 l; 1.2 l with Common Rail Fuel Injection System 81 Bluetooth in ŠKODA Cars 82 Motor Vehicle Sensors - Drivetrain 83  1.4 l/132 kW TSI Spark-Ignition Engine, Double Supercharged (Compressor, Turboblower) 84 ŠKODA Fabia II RS; Presentation of the Vehicle 85 KESSY System in ŠKODA Cars 86 START-STOP System in ŠKODA Cars 87 Immobilizers in ŠKODA Cars 88 Brake and Stabilization Systems 89 Sensors in ŠKODA Cars – Safety and Comfort 90 Customer Satisfaction Enhancement through CSS Study 91 ŠKODA Car Wiring Repairs 92 ŠKODA Citigo – Presentation of the Vehicle 93  Five-Speed 0CF Mechanical Gearbox and ASG Automated Five-Speed Gearbox 94  0AM and 02E Automatic Gearbox Diagnostics 95  ŠKODA Rapid – Presentation of the Vehicle 96  ŠKODA Octavia III – Presentation of the Vehicle – Part I 97  ŠKODA Octavia III – Presentation of the Vehicle – Part II 98  ŠKODA Octavia III – Electronic systems 99  Engines 1.8 l TFSI 132 kW and 2.0 l TFSI 162 kW - EA888 100 1.6 l TDI and 2.0 l TDI; EA288 Design Series 101 EA211 series spark-ignition engines 102 CNG system in vehicles ŠKODA AUTO 103 ŠKODA Fabia III – Vehicle presentation – Part I 104 ŠKODA Fabia III – Vehicle presentation – Part II 105  T hree-cylinder combustion ignition engine 1.4 l TDI – EA288 106 ŠKODA Superb III – Vehicle Presentation – part I 107 ŠKODA Superb III – Vehicle Presentation – part II 108 ŠKODA Superb III – Vehicle Presentation – part III 109 Connectivity in vehicles ŠKODA AUTO 110  Refrigerant R1234yf for air conditioning systems in ŠKODA AUTO vehiclesŠKODA Service®44110GBAll rights and technical modifications reserved. SSP00011020 GB Technical condition 5/2016 © ŠKODA AUTO a. s. https://portal.skoda-auto.comThe training material is intended for the use of professional service stations,performing service interventions o ŠKOADA vehicles, and is protected by copyright, with proprietary rights being executed by ŠKODA AUTO a.s., without a prior consent of which the document or its parts may not be modified, distributed by sales, lent, or otherwise communicated to the public through the Internet or other communication media.ProCarManuals.com