TECHNICAL DOCUMENTATION
SSP 280 The Phaeton Auxiliary heater

This PDF is currently unavailable.
Read document text
Service.Self-study programme 280The Phaeton Auxiliary heater Thermo TOP C and supplementary heater Thermo TOP ZDesign and functionThe use of heater units that work independently of the engine is continually rising. They are offered as an accessory for retrofit or as an optional extra by the manufacturer. The petrol engine Phaeton features an auxiliary heater as an optional extra that heats the interior when the engine is not running.For diesel engines, the Phaeton is fitted as standard with a supplementary heater that boosts coolant heating when the engine is running. In this way, the operating temperature of the engine is reached faster and is maintained throughout operation at an equal level. This self-study programme provides you with an overview of the auxiliary heater and the supplementary heater installed in the Phaeton.S280_053NEWImportant NoteThis self-study programme explains the design and function of new developments. The contents will not be updated.Please refer to the relevant service literature for current inspection, adjustment and repair instructions.2ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Coolant circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Operating stages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Deactivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Explanation of highlighted termsTest yourself . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483IntroductionThe auxiliary heaterThe auxiliary heater is a wise choice as an accessory. The heater and ventilation function provides a comfortable environment in the interior, which is available as soon as you climb into the vehicle.Frosted or steamed up windows inhibit all-round view. Therefore, they are a considerable risk in traffic situations. Heavy winter clothing, when worn in the vehicle, results in loose seat belts as they are no longer comfortably taut against the body. The optimal efficiency of the seat belt is markedly impaired. A further disadvantage is that unsuitable clothing restricts freedom and thereby also the ability to react quickly to given situations.S280_013By heating up the interior before the journey is started, the windows are cleared. Good all-round view is guaranteed. Less restrictive clothing in a preheated vehicle increases the efficiency of seat belt protection and reaction time of the wearer.S280_012Further, use of an auxiliary heater is financially viable. In many regions, the temperature on 100 days of the year is less than +5 °C, which equals a third of a year of operation.4The supplementary heaterThe diesel engines in the Phaeton feature a heater that works to boost heat. When the engine is started, the coolant is heated additionally by the supplementary heater. This helps diesel engines to make use of their good efficiency and reach their operating temperature in a short space of time. The heat generated from the combustion process is an unavoidable side-effect. The energy stored within is converted partly into heat instead of power. This has the effect of reducing the degree of efficiency. Direct injection diesel engines reach a high level of efficiency thanks to their optimised combustion process. The use of a supplementary heater supports the high level of efficiency in the engine by heating of the coolant. In addition, the passenger compartment is heated comfortably.5OperationActivationThe auxiliary heater can be operated in a number of different ways:●● ●Immediate start is carried out via the front information display and operating unit, in the sub-menu of the air conditioning system. Programming a fixed start time is done via a timer in the same sub-menu. Additionally, the auxiliary heater can be started using a remote control.Immediate start By pressing the auxiliary heater function button, the sub-menu can be accessed for auxiliary heater control. The heater button allows manual activation and deactivation of the auxiliary heater.Front information display and operating unit Heater button for immediate startHeater22°COther functions/Auxiliary heater Timer (duration:10 min)Monday 06:2092.8 MHz TP 22°C A/C Duration DayDeparture timeBackSelectionS280_0086Timer preselection The start time for the heater can be programmed in the sub-menu. To do this, the weekday, the start time and the desired duration should be entered using the operating elements. When the weekday and time have been reached, auxiliary heater operation will begin. In addition, the weekday will jump automatically to the next day.Display: Timer preselection22°C92.8 MHzTP22°CHeaterA/C Other functions/Auxiliary heater Timer (duration:10 min)Monday Tuesday 06:20 08:50DurationDay Departure timeDisplay: Weekday, timeBackSelectionS280_061Display: Set duration22°C92.8 MHzTP22°CA/C ..../Auxiliary heater/Heating durationDisplay: DurationBack15 minConfirmationS280_021When the auxiliary heater is activated at temperatures above +22 °C, auxiliary ventilation is activated automatically.7OperationRemote start The auxiliary heater features an additional remote control, which is not integrated in the vehicle key. With this remote control, the auxiliary heater is switched on and off remotely. The on button serves to start the heater and the off button is used to switch it off. For power supply of the remote control, a battery is necessary. The range of the remote control in open areas is approx. 600 m. The control lamp of the remote control lights up green when the auxiliary heater is switched on, and red when it is switched off.Remote control Control lampOn buttonOff buttonS280_023Opening for battery replacementS280_0668The radio signal from the remote control is pikked up by an aerial, which is installed in the upper area of the rear window, and transmitted to a receiver located beneath the rear shelf.The signal is sent to the auxiliary heater control unit (J255) by pulse width modulated transmission along a special data lead.Aerial Overview of associated components Remote controlRadio receiverAuxiliary heater control unitS280_019The remote control must be coded to the radio receiver. A maximum of two remote controls can be coded. The work procedure necessary is described in the electronic service information system (ELSA).9OverviewFitting locationsThe components necessary for operation of the auxiliary heater or the supplementary heater are installed in the vehicle decentrally.Overview of fitting locationsPump valve unit, front right in vicinity of plenum chamberAuxiliary/supplementary heater with control unit, front left beneath wing10Aerial for remote start, beneath rear window upper trimRadio receiver, beneath rear shelfMetering pump, above rear axle, left of centreCoolant shutoff valve, on left in engine compartmentS280_01711ConstructionThe componentsThe auxiliary heater and the supplementary heater consist of: recirculating pump V55, combustion air blower V6, control unit J255, burner housing, combustion chamber with flame pipe and glow plug Q9 (with flame monitor) in burner housing, - coolant jacket. Additional components are:- metering pump V54 and - coolant shutoff valve N279.Thermo Top Z/C (heater)Control unitCombustion air blower V6Coolant jacketRecirculating pump Combustion chamber in burner housing Burner housingS280_00212The recirculating pump V55When the engine is switched off, coolant is circulated by a recirculating pump. This is actuated electrically by auxiliary heater control unit J255.Recirculating pumpCross section Permanent magnet Iron coreCoilPump rotorS280_007S280_057Actuation Actuation is by the auxiliary heater control unit.S280_04413ConstructionThe combustion air blower V6The air required for combustion is drawn in via an air intake pipe with silencer by the combustion air blower, then via the air channel to the fuel evaporator (fleece) and further to the combustion chamber.Main viewCombustion air blowerSilencer and filter element SilencerS280_003Air intakeS280_05814Blower rotor with vanesBlower motorS280_059ActuationHousingThe combustion air blower is supplied with voltage direct from the control unit via a two pin connector.Air intakeS280_055 S280_04715ConstructionThe auxiliary heater control unit J255As primary control unit, the control unit guarantees the functional sequence and monitor heater operation. Connection to the vehicle onboard electrical system is via a connector strip. The supplementary heater and the auxiliary heater differ in control unit codes and connection to the coolant circuit. In addition, the auxiliary heater has a remote start function and a coolant shutoff valve.Main viewConnector stripControl unitS280_00416Control unit openedGlow plug with flame monitor Q9 Recirculating pump V55S280_035S280_054Combustion air blower V6 Connector to onboard electrical system Power supply Temperature senderTemperature monitoring Coolant temperature is monitored in the heater and heater operation is regulated via the temperature sender G241. At coolant temperatures above 125 °C, the heater is shut off and locked. To unlock, follow the instructions on the diagnosis, testing and information system VAS 5051 and the electronic service information system (ELSA).S280_06517ConstructionThe burner housingLocated on the burner housing are: the coolant outlet, the exhaust pipe, the coolant inlet and the combustion chamber.Burner housing Coolant outletCombustion chamberCoolant inletS280_027Exhaust pipeFurther, the burner housing houses the combustion chamber and forms a unit with the coolant jacket and the control unit.18The combustion chamber with flame pipe and heater glow plug Q9 (with flame monitor)Formation of the fuel-air mixture takes place in the combustion chamber. This mixture is then burnt in the flame pipe. The glow plug with flame monitor can be found in the combustion chamber. This ignites the fuel-air mixture initially. During the heating stage, the glowing walls of the combustion chamber ignite the fuel-air mixture. The glow plug is designed as an electrical resistor and features a flame monitor. It monitors the temperature of the flame during the whole phase of heating.Combustion chamber Flame pipe Combustion air inlet Combustion chamber cross sectionCombustion air inletFlame pipeS280_005Fuel intakeGlow plug with flame monitorS280_056Combustion air inlet into fuel evaporatorCombustion chamber19ConstructionThe coolant jacket.The heat generated from combustion is conveyed to the coolant via the coolant jacket. Coolant enters the housing via the coolant inlet of the coolant jacket (heat transmitter). The necessary heat is then drawn for heating. Coolant leaves the housing via the coolant outlet.Coolant jacket cross section Space for combustion chamberMain viewCoolant inletS280_060Space for coolant (transfer of heat) Coolant outlet Coolant jacketS280_00420The exhaust systemThe heater features its own exhaust system, which consists of an exhaust pipe and silencer. The exhaust system channels the exhaust gas generated from heater combustion to the outside independently of the vehicle exhaust system. In order to guarantee safe operation of the heater, the prescribed length of the exhaust system should not be altered. The length is set to balance the combustion vibrations of the heater.Exhaust pipeSilencerS280_02521ConstructionThe metering pump V54Supply of fuel from the fuel tank of the vehicle to the heater is by metering pump. The pump is designed as a combined supply, metering and shutoff system. This means that fuel is metered during operation and fuel supply is blocked when the heater is switched off.Fitting locationS280_014ActuationS280_063The metering pump can be found above the rear axle. To remove the pump, the rear axle has to be lowered. In order to ensure correct ventilation of the pump, the prescribed fitting location must not be changed.S280_046The metering pump is pulse-actuated via the control unit based on the required heater output.22Functional description The metering pump is of the plunger type, in which the armature is attached permanently to the pump plunger.Supply of fuel The metering pump is filled with fuel when there is no voltage. When the coil is energised, the armature pushes the pump plunger against the spring. The pump plunger lifts up the ball valve and delivers fuel from the pump chamber. At the same time, the supply hole to the pump chamber is closed.CoilPump plunger Pump chamberS280_067ArmatureSpring Inlet holeBall valveFuel suction During this period, fuel flows in the armature chamber. When the coil is not energised, spring pressure forces the armature and the pump plunger back. The resulting vacuum draws fuel into the pump chamber via the opened inlet holes.ArmaturePump plungerS280_062This kind of operation allows a high level of metering accuracy, high durability and low noise generation.Armature chamberInlet holePump chamberAn animated view of the function can be found on the internet at "www.thomas-magnete.com"23ConstructionCoolant shutoff valve N279Only the auxiliary heater features a coolant shutoff valve. When the auxiliary heater is in operation, engine coolant circulation is separated from the heat exchangers to the interior. Separation is via the coolant shutoff valve.From pump valve unitTo engineFitting location The coolant shutoff valve can be found on the left in the engine compartment.S280_016To heaterPlugS280_064Actuation The auxiliary heater control unit actuates the valve directly.S280_04824Normal operation When there is no power, the coolant shutoff valve connects the coolant circuit between the pump valve unit and engine circuit.CoilFrom pump valve unitTo engineS280_051To heaterValve plunger PlugHeater operation The shutoff valve is actuated and the pump valve unit is connected with the auxiliary heater. In this way, the interior of the vehicle is preheated and not the engine.Coil To engine From pump valve unitTo heater Valve plunger PlugS280_05025Coolant circuitConnection of auxiliary heater in coolant circuit of W12 engineIf the auxiliary heater is started when the engine is switched off, the coolant shutoff valve closes. The recirculating pump pumps coolant through the coolant jacket in the auxiliary heater to the pump valve unit, then through the heat exchanger inside the vehicle and back to the auxiliary heater. The vehicle interior is heated.Coolant circuitGearbox oil coolerEngine oil cooler Alternator CCylinder blockCoolant shutoff valve N27926Function When voltage is applied to the shutoff valve, coolant can flow from the pump valve unit to the heater. When there is no voltage at the shutoff valve, coolant can flow from the pump valve unit to the engine.RadiatorContinued coolant circulation pump V51 Air reservoir ThermostatExpansion tankRight heat exchangerLeft heat exchangerPump valve unitS280_015The pump valve unit is part of the vehicle heater and is described in SSP 271.Recirculating pump V55Auxiliary heater27Coolant circuitConnection of auxiliary heater in coolant circuit of V10 TDI engineOn the supplementary heater there is no coolant shutoff valve. The heater is permanently connected to the engine coolant circuit.Coolant circuitCheck valveContinued coolant circulation pump V51Fuel cooling pump V166Low temperature cooler for alternator and fuel coolingRadiator28Expansion tankRight heat exchangerLeft heat exchangerPump valve unitS280_052Recirculating pump V55Supplementary heater29FunctionAir supplyThe air required for combustion is drawn via the combustion air intake from the combustion air blower and passed through the combustion air channel to the combustion chamber.Combustion air blower V6 Coolant outletCombustion air inletCombustion air channelRecirculating pump V55Fuel channelCoolant inletExhaust pipe Fuel evaporator Metering pump V54 Heater glow plug Q9 (with flame monitor)30The fuel supplyFuel is supplied through the fuel channel. In the fuel evaporator (fleece), fuel is mixed with the combustion air, forming a combustible fuel-air mixture. The glow plug with flame monitor ignites the mixture in the combustion chamber at the start. Once operation has begun, ignition occurs at the flame front in the flame pipe. During operation of the heater, the glow plug Q9 is supplied with only a small amount of energy from the control unit. The electrical resistance of the glow plug can thus be used as a flame monitor.Flame pipeCombustion chamber in burner housingCoolant jacketThe coolantCoolant enters through the coolant inlet in the coolant jacket. Here, it is heated. The heated coolant flows out the coolant outlet into the coolant circuit.S280_01031Operating stagesThe auxiliary heaterStart phase The auxiliary heater is started either: - immediately, - via the timer or - using the remote control. The output of the combustion air blower is increased in stages to full load and the fuel-air mixture is delivered to the combustion chamber. Combustion begins. If no flame is formed or the flame dies, restart is initiated automatically. After a total of 90 seconds of fuel delivery without flame formation, the system is switched off until the ignition is switched on again (terminal 15).The combustion air blower and the recirculating pump are actuated. The glow plug starts to glow and the combustion air blower pumps air into the burner insert. After about 30 seconds, the metering pump starts to deliver fuel and the combustion air blower is switched off for about 5 seconds until a rich mixture has built up.Pr e St glo ar w to fc om Fu bu ll lo sti ad on Fr op es e ra h ai tio rb n lo we Pa r rt lo adRecirculating pump Glow plug Combustion air blower VL Combustion air blower TL Metering pump VL Metering pump TL Flame monitor interrogation Fresh air blowerTemperature in °C 9085 80 75 70 5Time in seconds3090 S280_03632Sh ut o St ff ar to fr En un d -o of n ru nonFu ll lo adar tPa rtStlo adHeating phase/regulated phase When the coolant reaches a temperature of 87 °C, the heater is switched from full load to part load. This reduces the combustion air blower output and the metering pump delivers less fuel. If the coolant temperature drops to approx. 83 °C, full load is activated again. At a coolant temperature of approx. 89 °C, heating is interrupted. When the coolant temperature drops to approx. 85 °C, heating is initiated once again.Pr e St glo ar w to fc om Fu bu ll lo sti ad on Fr op es e ra h ai t r b ion lo we Pa r rt lo adRecirculating pump Glow plug Combustion air blower VL Combustion air blower TL Metering pump VL Metering pump TL Flame monitor interrogation Fresh air blowerTemperature in °C 9085 80 75 70 S280_037Fu llSh ut of St f ar to fr En un d -o of n ru nonar tlo adPa rtStlo ad33Operating phasesRun-on phase The auxiliary heater is deactivated by: - switching off the engine, - switching off the auxiliary heater or - expiration of the automatic heating duration (max. 60 minutes). Run-on time depends on the type of heater and can be between 100 and 175 seconds. The run-on time for petrol-driven heaters is:● ●168 seconds when switched off from full load 157 seconds when switched off from part loadThe metering pump is switched off, combustion stops, the combustion air blower and the recirculating pump run-on to cool down and are then switched off automatically.The run-on time for diesel-driven heaters is: 175 seconds when switched off from full load 100 seconds when switched off from part load There may be slight deviations in the given figures depending on the development of the software.● ●Pr e St glo ar w to fc om Fu bu ll lo sti ad on Fr op es e ra h ai t r b ion lo we Pa r rt lo adRecirculating pump Glow plug Combustion air blower VL Combustion air blower TL Metering pump VL Metering pump TL Flame monitor interrogation Fresh air blowerTemperature in °C 8580 70 60 50 S280_038Time in seconds34Sh ut of St f ar to fr En un d -o of n ru nonar tlo adFu llPa rtStlo ad100 - 175The supplementary heater (diesel engines)Run-on phase Start phase When the engine is started, the heater is made ready. When the coolant temperature is below 60 °C, ambient temperature is below + 5 °C and the control unit has received an engine speed signal, start is initiated. Heating phase If the coolant reaches 78 °C, operation is interrupted. When the coolant temperature reaches 76 °C, full load operation is switched to part load. The transition from part load to full load comes at 70 °C and to part load at 65 °C. When the engine is switched off, the supplementary heater is stopped. Combustion is stopped and run-on begins. The supplementary heater run-on time is: 175 seconds when switched off from full-load ● 100 seconds when switched off from part-load There may be slight deviations in the given figures depending on the software version.●Pr e St glo ar w to fc om Fu bu ll lo sti ad on Fr op es er h at ai r b ion lo we Pa r rt lo adRecirculating pump Glow plug Combustion air blower VL Combustion air blower TL Metering pump VL Metering pump TL Flame monitor interrogation Fresh air blowerTemperature in °C 8075 70 60 50 S280_020Time in secondsFu llSh ut of St f ar to fr En un d -o of n ru nonar tlo adPa rtStlo ad100 - 17535DeactivationDeactivation conditionsThe auxiliary heater and the supplementary heater are switched off for reasons of safety under certain conditions.Vehicle-specific deactivation The auxiliary heater is switched off when: - the tank flap is opened, - the fuel level is low, - the onboard electrical system is placed under heavy load by the onboard electrical system control unit, - an airbag is triggered by an accident - heater output is sufficient during normal driving.S280_024Temperature related deactivation If the coolant temperature rises above 105 °C during heater operation, fuel supply is interrupted. In this instance, the heater will run-on for approx. 120 seconds. If there is a fault in the combustion air blower, there will be no run-on.DeactivationHeater operationS280_02836Deactivation due to excessive or insufficient voltage In addition to monitoring of the onboard electrical system voltage by the onboard electrical system control unit, the auxiliary heater control unit also deactivates the heater if excessive or insufficient voltage is detected. Fixed deactivation due to insufficient voltage If the battery voltage drops to below 9.5 volts for longer than 6 seconds, the heater is deactivated with a run-on time of 120 seconds.Heater operationDeactivationS280_029Deactivation due to excessive voltage If the battery voltage exceeds 15.5 volts for more than 60 seconds, the auxiliary heater is deactivated.37NetworkingCommunication via CAN data busThe auxiliary heater control unit is connected with the other control units in the vehicle via the infotainment CAN data bus and the diagnosis data bus interface in the dash panel. All the necessary information can be exchanged with other control units via this data network.Roof electronics control unit J528Climatronic/air conditioning control unit J301 Control unit for front information display and operating unitOnboard electrical supply control unit J519Climatronic operating and control unit E265Entry and start authorisation control unit J518Door control unit, driver side J38638Control unit for front information display and control unit J523Data bus diagnosis interface J533 in dash panelAuxiliary heater control unit J255Data bus diagnosis interface Drive train CAN data bus Convenience CAN data bus Infotainment CAN data busS280_03439NetworkingThe data bus messagesA) FunctionAuxiliary heater messages received from remote commands and from modes of operationB) MessageActivation via remote control Activation of blower Activation of control LEDCommands and information to auxiliary heater control unitActivation of auxiliary heater Tank warning on Convenience CAN data bus messages Ignition on Operating commands e.g. auxiliary ventilation e.g. immediate start Auxiliary heater operating mode Heating duration Start timeTerminal information Auxiliary heater operationAuxiliary heater operationProgramming of auxiliary heaterActuation of auxiliary heaterAuxiliary heater operating modeAuxiliary heater duration informationAuxiliary heater durationHeater deactivationTank flap openedHeater deactivationOnboard electrical system critical battery levelHeater deactivationCrash impact signalStatus informationEngine speed Ambient temperature Engine type40C) SenderAuxiliary heater control unitD) ReceiverControl unit with display unit in dash panel insert Climatronic/air conditioning control unit Roof electronics control unit Entry and start authorisation control unit Onboard electrical supply control unit Control unit for front information display and operating unit Climatronic/air conditioning operating and display unit Additional water heater control unitControl unit with display unit in dash panel insertControl unit with display unit in dash panel insert Control unit with display unit in dash panel insertAuxiliary coolant heater control unit Auxiliary heater control unit Climatronic/air conditioning control unitControl unit for front information display and operating unit Control unit for front information display and operating unit Climatronic/air conditioning control unitControl unit with display unit in dash panel insertControl unit with display unit in dash panel insertClimatronic/air conditioning operating and display unit Control unit with display unit in dash panel insert Control unit for front information display and operating unit Climatronic/air conditioning control unitControl unit with display unit in dash panel insertDoor control unit, driver sideControl unit with display unit in dash panel insertOnboard electrical supply control unitControl unit with display unit in dash panel insertControl unit with display unit in dash panel insert on receipt of message from airbag control unit Control unit with display unit in dash panel insertAuxiliary heater control unitAdditional coolant heater control unit41Functional diagramKeyA BatteryG241 Coolant temperature sender, heater J255 Auxiliary heater control unit on auxiliary heater J285 Control unit with display unit in dash panel insert J533 Data bus diagnosis interface N279 Coolant shutoff valve, heater Q9 Heater glow plug Q9 (with flame monitor) AerialR11R149 Auxiliary heater remote receiver, beneath rear shelf S V6 Fuse Combustion air blowerV54 Metering pump V55 Recirculating pumpV54 V55YAnalogue clockASignal output Earth Signal output Positive Infotainment CAN data bus42J285J533YG241Q9R11J255R149V6N279S280_04343ServiceDiagnosisDiagnosis can be carried out using the testing and diagnosis system VAS 5051. Communication is via the diagnosis interface. The exchange of data between the diagnosis system and the diagnosis interface in the dash panel insert is via the COM lead. Continued exchange of data is via the infotainment CAN data bus. If the data bus is defective or the data bus diagnosis interface is defective, diagnosis is not possible. A description of the individual diagnosis functions can be found in the guided fault finding program on the testing and diagnosis system VAS 5051. These are accessed automatically. The following components are monitored by the diagnosis system:● ● ● ● ● ●Auxiliary heater control unit Combustion air blower Glow plug Metering pump Coolant shutoff valve Recirculating pumpAdditionally, the power supply and data bus communication are checked and any faults are stored in the fault memory.Testing and diagnosis system VAS 505144Combustion air blowerGlow plugData bus diagnosis interfaceMetering pumpRecirculating pumpShutoff valveS280_01845GlossaryDiagnosis interfaceThe diagnosis interface is a virtual control unit in the dash panel insert. It transmits CAN data bus messages from one CAN data bus to the next and also transmits data from the COM lead to the CAN data bus linesLoose beltThe distance between the seat belt and the upper body (thorax). The heavier the clothing, the greater the distance between upper body and seat belt. This distance has to be balanced by the belt tensioner in a collision.Degree of efficiencyThe relationship between the energy supplied and energy returned. The chemical energy stored in the fuel is converted partly into mechanical energy and thereby into kinetic energy. The remaining energy ends up as heat, exhaust gas and radiant energy.4647Test yourself1. The auxiliary heater is activated
a) automatically when the ignition is switched on.
b) by the on/off switch in the driver's door.
c) by the immediate start function in the information display and operating unit.2. The fixed start time is programmed
a) by the timer preselection in the front information display and operating unit.
b) by the preselection clock in the driver's door.
c) by the analogue clock setting in the dash panel insert.3. Remote start
a) is initiated by dialing telephone number 0800 89 73 74 23 and giving the start time to thecentre.
b) is initiated by pressing the start button on the remote control.
c) is initiated by pressing the open button on the ignition key.4. When the engine is not running, the auxiliary heater heats
a) the engine.
b) the interior via the pump valve unit and the left and right heat exchangers.
c) the interior via the pump valve unit and the left and right heat exchangers,the luggage compartment and the engine.485. In the start phase of auxiliary heating
a) the combustion air blower is switched off for 5 seconds so that a rich mixture iscreated.
b) the metering pump is increased to 150 % delivery so that a rich mixture is created.
c) the combustion air blower delivers more air to create a leaner mixture.6. The auxiliary heater is switched off if
a) during the start phase there is no independent flame.
b) the coolant temperature rises above 105 °C.
c) the battery voltage is less than 9.5 volts for six seconds.7. The auxiliary heater control unit
a) communicates with other control units in the vehicle via the drive train CAN data bus.
a) communicates with other control units in the vehicle via the convenience CAN data bus.
c) communicates with other control units in the vehicle via the infotainment CAN data bus anddata bus diagnosis interface in the dash panel insert.Answers 1c; 2a; 3b; 4b; 5a; 6a,b,c; 7c;49Notes5051280For internal use only © VOLKSWAGEN AG, Wolfsburg All rights and the right to make technical alterations reserved 240.2810.99.20 Technical status 02/03❀ This paper was manufactured from pulp thatwas bleached without the use of chlorine.