TECHNICAL DOCUMENTATION
SSP 880153 – The Heat Pump from Volkswagen

This PDF is currently unavailable.
Read document text
Service TrainingSelf Study Program 880153The Heat Pump from VolkswagenDesign and FunctionVolkswagen Group of America, Inc. Volkswagen Academy Printed in U.S.A. Printed 7/201 5 Course Number SSP 8801 53©201 5 Volkswagen Group of America, LLC. All rights reserved. All information contained in this manual is based on the latest information available at the time of printing and is subject to the copyright and other intellectual property rights of Volkswagen Group of America, LLC., its affiliated companies and its licensors. All rights are reserved to make changes at any time without notice. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, nor may these materials be modified or reposted to other sites without the prior expressed written permission of the publisher. All requests for permission to copy and redistribute information should be referred to Volkswagen Group of America, Inc. Always check Technical Bulletins and the latest electronic repair information for information that may supersede any information included in this booklet. Trademarks: All brand names and product names used in this manual are trade names, service marks, trademarks, or registered trademarks; and are the property of their respective owners.ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Basic Principle of the Heat Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 The Heat Pump in the e-Golf. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Function of the Heat Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 System Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Knowledge Assessment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28NoteImportant!This Self-Study Program provides information regarding the design and function of new models.This Self-Study Program is not a Repair Manual. This information will not be updated. For maintenance and repair procedures, always refer to the latest electronic service information.iPage intentionally left blank for printing purposesIntroductionHeat pump technology has been used in buildings for many years to reduce heating and cooling costs. At Volkswagen, this efficient technology is being used to produce heat in the e-Golf. The heat pump system is a refrigerant circuit that is made up of numerous components. In this SSP, we will simply call it the heat pump. In cars with an internal combustion engine, the heat produced by the engine can be used to heat the passenger compartment. Electrically driven vehicles, however, do not produce enough thermal energy to heat the vehicle interior. Using a heat pump allows the heat from the outside air and the heat produced by the drive components to heat the vehicle interior. As a result, less battery power is required by the electrical high-voltage heater, reducing energy consumption. The range of the e-Golf with a heat pump is 30% greater with a heat pump than without one.s532_0061IntroductionPhysical LawsWhat is heat? Heat (mathematical symbol of Q, unit of joule) is a form of energy that is transferred between two systems due to temperature differences. Heat always flows from a body of high temperature to a body of low temperature. Heat can be transferred through thermal conduction, thermal radiation or convection.s532_002Phase Transition There are three primary states of matter that substances can change between due to temperature or pressure; solid, liquid and gas.The phases of waterFreezingCondensationTo change its state of matter, a body must either absorb or release thermal energy: • Melting: The transition from solid to liquid state. Heat is absorbed. • Vaporization: The transition from a liquid to a gaseous state. Heat is absorbed. • Condensation: The transition from a gaseous to a liquid state. Heat is released. • Freezing: The transition from a liquid to a solid state. Heat is released.Solid Melting Liquid Vaporization Gas2IntroductionHeat PumpGeneral InformationHeat pump technology makes use of these laws. Water flows downhill by itself, but needs to be pumped uphill. The same can be said of heat: it automatically “flows” from a higher to a lower temperature level. Heat pumps use electrical energy to pump heat against the natural “temperature flow” from a lower to a higher temperature level. Task Heat pumps transport thermal energy from one location to another. They have been used in buildings for a long time for heating. Heat pumps have lower energy consumption, lower pollution levels and lower operating costs than traditional heating methods.Source of Heat Heat Pump Heatings532_004When reversed, this principle is used for cooling in refrigerators and air conditioning systems.3IntroductionRefrigerantThe heat pump uses R134a refrigerant. It is a chlorofluorocarbon (CFC) with a low boiling point. R134a is invisible in gas form and is colorless like water when in vapor and liquid states.CharacteristicsF• Designation: • Chemical formula: • Boiling point: • Solidification point: • Critical pressure: tetrafluorethane CH2F-CF3 -26.5°C (at approx. 1 bar) -101.6°C 4.056 MPa (40.56 bar)HF C C F HF• Critical temperature: 100.6°Cs532_042Pressure and Boiling PointThe boiling point is the temperature at which a substance changes from liquid to gaseous state. The boiling point of a substance is always given at normal atmospheric pressure (1 .01325 bar). The boiling temperature varies according to the pressure. It falls at low pressure and rises at high pressure. This behavior is illustrated as an evaporation curve in the pressuretemperature graphs.Water bar 1 .0 0.9 0.8 0.7 Pressure [bar] 0.6 0.5 0.4 0.3 0.2 0. 1s532_052R134a9 8 7 Pressure [bar] 6 5 4 3 2 1s532_0540 10 20 30 40 50 60 70 80 90 100-40-200204060These physical properties of R134a refrigerant are used in the heat pump. By specifically changing the pressure and the temperature, the refrigerant is able to: –– evaporate and absorb heat at ambient temperature or –– condense and release heat at ambient temperature.4Basic Principle of the Heat PumpCircuit DesignA heat pump basically consists of the following main components: a compressor, an evaporator, an expansion valve and a condenser. In the closed heat pump circuit, the refrigerant circulates and changes between liquid and gaseous state, transferring and transporting heat. There is always a high pressure side and a low pressure side in this circuit.Outside Air (airflow/fan) Expansion Valve Evaporator Cooled Air Outside Air (airflow/fan) Electrical Power SupplyCompressor Heated Air for Interiors532_033CondenserFunction • The compressor draws in cold, gaseous refrigerant at low pressure and compresses it under high pressure. The temperature rises. In this phase, the refrigerant is gaseous and under high pressure at a high temperature. • Cold air (airflow/fan) flows through the condenser. The refrigerant transfers heat to the air and condenses. The heated air flows into the interior. In this phase, the refrigerant is liquid and under high pressure at medium temperature. • The pressure of the liquid refrigerant is reduced significantly in the expansion valve. The reduced pressure leads to partial evaporation of the refrigerant. After expansion, the temperature of the refrigerant is significantly lower than the ambient temperature. • In the evaporator, the pressure of the refrigerant being sprayed is further reduced and it evaporates. The heat of vaporization required for this process is drawn from the warmer outside air, which then cools. The now gaseous refrigerant leaves the evaporator.5Basic Principle of the Heat PumpPhase Diagram of R134a RefrigerantThis diagram represents the phases of R134a in a heat pump circuit. You can see the energy content, the pressure, the temperature and the state of the refrigerant in each process. Other absolute values occur depending on the outside air temperature and the heating requirement inside the vehicle.Pressure [bar]s532_012Energy Content (kJ/kg)Gaseous Refrigerant Wet Steam Region of Refrigerant Liquid Refrigerant Gas/liquid Region BorderlineHigh-pressure Region Low-pressure Region Line of Constant Temperature (temperature curve)Explanation A - B: compression The refrigerant is gaseous; the pressure and the temperature rise. B - C: condensation The refrigerant turns to liquid, the temperature falls and the pressure remains constant. C - D: expansion The pressure reduction leads to partial evaporation of the refrigerant and the temperature falls. D - A: evaporation The refrigerant becomes completely gaseous, the temperature rises slightly and the pressure remains constant. K: critical point The boiling line is to the left of the critical point and the saturated vapor line is to the right of it.6The Heat Pump in the e-GolfSystem ConfigurationComponents like the electrical air conditioner compressor, the evaporator and the condenser run the air conditioning system in the e-Golf. The refrigerant circuit of the air conditioning system has been expanded for use with the heat pump to include refrigerant lines, electrical expansion valves, pressure senders, temperature senders and a heat condenser. Since the heat pump system for the e-Golf also uses the heat produced by the motor and the power and control electronics for electric drive, a second expansion valve and a heat exchanger for the heat condenser are used in parallel to heat pump circuit.Refrigerant CircuitPressure and Temperature Sensors Expansion/Shut-off ValvesCondenserElectrical Air Conditioner CompressorHeat Exchanger for Heat Condenser Evaporators532_007Heat Condenser7The Heat Pump in the e-GolfSchematic Diagram of the Coolant and Refrigerant CircuitsThis schematic diagram provides a basic illustration for subsequent descriptions of components and the functions of the heat pump.V470 G395G829 ReservoirN642Refrigerant CircuitN643 G827N696 N636 G826CondenserG828N637 N638 Heat Condenser EvaporatorHeat Exchanger for Heat Condenser G1 10G787 Z1 1 5 G785Non-return ValveAX4Coolant CircuitV509 N632 G789 JX1 V508 G83s532_090G931VX54G788N687Radiator8The Heat Pump in the e-GolfKey AX4 High Voltage Battery Charger 1 G83 Engine Coolant Temperature Sensor on Radiator Outlet G110 A/C Engine Coolant Temperature Sensor G395 A/C Pressure/Temperature Sensor G785 Temperature Sensor in Front of High Voltage Heater (PTC) G787 Temperature Sensor after Heat Exchanger G788 Temperature Sensor after Electro-Drive Drive Motor G789 Temperature Sensor after Electric Drive Power and Control Electronics G826 A/C Pressure/Temperature Sensor 2 G827 A/C Pressure/Temperature Sensor 3 G828 A/C Pressure/Temperature Sensor 4 G829 A/C Pressure/Temperature Sensor 5 G931 Temperature Sensor Before Charger JX1 Electric Drive Power and Control Electronics N632 Coolant Change-Over Valve 1 N636 Refrigerant Expansion Valve 1 N637 Refrigerant Expansion Valve 2 N638 Refrigerant Expansion Valve 3 N642 Refrigerant Cut-off Valve 4 N643 Refrigerant Cut-off Valve 5 N687 Radiator Bypass Switch-over Valve N696 Refrigerant Cut-off Valve 1 V470 Electrical A/C Compressor V508 Coolant Pump In Front of Electric Drive and Power Control Electronics V509 Coolant Pump In Front if High Voltage Heater (PTC) VX54 Three-phase Current Drive Z115 High Voltage Heater (PTC) Refrigerant Circuit Coolant Circuit The following terms are shortened in the remainder of this SSP: • N636 Refrigerant Expansion Valve 1 to Expansion Valve 1 (EV1) • N637 Refrigerant Expansion Valve 2 to Expansion Valve 2 (EV2) • N638 Refrigerant Expansion Valve 3 to Expansion Valve 3 (EV3) • N696 Refrigerant Cut-off Valve 1 to Cut-off Valve 1 (SV1) • N642 Refrigerant Cut-off Valve 4 to Cut-off Valve 4 (SV4) • N643 Refrigerant Cut-off Valve 5 to Cut-off Valve 5 (SV5)9ComponentsElectrical Air Conditioner CompressorLocation The Electrical A/C Compressor V470 is bolted to the Threephase Current Drive VX54.Electrical A/C CompressorDesign The e-Golf with heat pump uses an electrical air conditioner compressor with an internal scroll compressor design. It is identical to the air conditioner compressor used in the e-Golf without a heat pump.s532_024Function The electrical A/C compressor draws in the gaseous refrigerant at low pressure. It is compressed, the pressure increases and the temperature of the refrigerant rises. The electrical A/C compressor pushes the refrigerant to the condenser as a hot gas. This compressor forms the separating point between the low and high-pressure sides of the refrigerant circuit.s532_02110ComponentsHeat Condenser and EvaporatorLocation of Heat Condenser/ EvaporatorThe heat pump in the e-Golf has a heat condenser and an evaporator. Both are located in the heater and air conditioning unit.EvaporatorDesign of Heat CondenserThe heat condenser is a serpentine-like pipe system with fins. This creates a large heat exchange area with good heat transfer. Airflow from the fan passes through the heat condenser.Heat Condensers532_026Heat CondenserHeat Condenser FunctionCondensation is the transition of matter from a gaseous to a liquid state. The hot, gaseous refrigerant reaches the condenser. The condenser pipes and fins absorb heat as cool outside air flows across the condenser. As it cools, it condenses and becomes a liquid. The cooled refrigerant is then guided into the vehicle interior.s532_00911ComponentsEvaporator DesignThe evaporator has a similar design to the heat condenser and also has an internal flow of refrigerant. Air from the heater and air conditioning unit flows through the evaporator. EvaporatorEvaporator Functions532_025The evaporator works as a condenser during heat pump operation (“heating” function). This means that the air flowing through the evaporator is heated.The evaporator works as an evaporator in “cooling” mode (function). This means that the air flowing through the evaporator is cooled.Expansion Valves and Cut-off ValvesLocations of Expansion Valves/ Cut-off ValvesThree expansion valves and three cut-off valves are used in the heat pump circuit: • N636 Refrigerant Expansion Valve 1 (EV1) • N637 Refrigerant Expansion Valve 2 (EV2) • N638 Refrigerant Expansion Valve 3 (EV1) • N696 Refrigerant Cut-off Valve 1 (AV1) • N642 Refrigerant Cut-off Valve 4 (AV4) • N643 Refrigerant Cut-off Valve 5 (AV5)N637 N638s532_028N643N642N696 N63612ComponentsExpansion ValveDesign of Expansion ValvesThe expansion valves have an identical design. A V-shaped control edge in the ball valve enables on-demand, stepless activation (0100 percent).s532_01 1Expansion Valve Function Refrigerant flows through the Expansion Valve 2 N637 from the evaporator in the direction of the condenser in “heating” operating mode (function). In “cooling” operating mode (function), the refrigerant flows through the expansion valve in the opposite direction. The refrigerant can expand in the expansion valve, i.e. fill a considerably larger space (volume enlargement). The pressure then falls significantly. The liquid refrigerant partially evaporates, causing the temperature to fall.Design of cut-off valvesCut-off Valve The cut-off valves are ball valves that are either fully open or fully closed.Cut-off Valve Function The cut-off valves regulate the flow direction of refrigerant in the refrigerant circuit.s532_01 7The expansion valves and cut-off valves are connected to the Thermal Management Control Module J1024 via the same LIN-Bus. Each compact valve connector has its own coded pin assignment.13ComponentsCondenserLocation The condenser is located between the radiator fan and the radiator.Design The condenser is a conventional air conditioner condenser.Condensers532_030Function The condenser operates either as an evaporator or a condenser according to the “cooling” or “heating” operating mode (function). It works as an evaporator in heat pump mode, i.e. in the “heating” function. Evaporation refers to the transition from a liquid to a gaseous state. In the evaporator, the refrigerant, which is no longer under pressure and is at ambient temperature, is completely evaporated. The heat required for this is drawn from the outside air that passes between the evaporator fins. The pressure of the refrigerant remains constant and the temperature rises slightly.s532_019The evaporator functions as a condenser in “cooling” operating mode (function).14ComponentsHeat Exchanger for Heat CondenserLocation The heat exchanger is located on a bracket mounted on the bulkhead in the engine compartment. Most of the heat pump components are mounted on it.Design The Heat Exchanger for Heat Condenser is just like conventional oil-to-coolant plate heat exchangers. The coolant circuit is separate from the refrigerant circuit. Heat is exchanged without direct contact between or mixing of the fluids.Heat Exchanger for Heat Condensers532_046Key Refrigerant circuit Coolant circuitFunctionConnections for RefrigerantIn the Heat Exchanger for Heat Condenser, the heat of the coolant is transferred to the refrigerant and the refrigerant evaporates. The heat from electronic components such as the threephase current drive, the power and control electronics for electric drive and the charging unit is used.Connections for Coolants532_01315ComponentsReservoirReservoirLocation The reservoir is upstream of the electrical air conditioner compressor in the refrigerant flow direction. The reservoir is located at the front right in the wheel housing.Design It is identical to the reservoir in other vehicles with air conditioning.s532_034Refrigerant Outlet to Electrical Air Conditioner CompressorRefrigerant InletFunction The reservoir is used in the refrigerant circuit as an expansion and supply tank for the refrigerant. Since the thermal loading of the evaporator and condenser and the speed of the electrical air conditioner compressor will vary during operation, different quantities of refrigerant will also be pumped through the circuit. The reservoir is incorporated into the circuit to compensate these fluctuations.s532_02316ComponentsRefrigerant Pressure and Temperature SensorsLocationG395 G829A total of five refrigerant pressure and temperature sensors are installed in the heat pump circuit. They are located on the assembly carrier:G827 G826• G395 A/C Pressure/Temperature Sensor • G826 A/C Pressure/Temperature Sensor 2 • G827 A/C Pressure/Temperature Sensor 3 • G828 A/C Pressure/Temperature Sensor 4G828• G829 A/C Pressure/Temperature Sensor 5s532_044Function The refrigerant pressure and temperature sensors measure the pressure and the temperature of the refrigerant, convert the readings into an electrical signal and send it to the heat pump control module. The following data is collected: • Refrigerant pressure 0 to 36 bar • Refrigerant temperature -40°C to +150°C • Internal temperature sender -40°C to +140°Cs532_01 5Failure Effects If one or more sensors fail, the refrigerant pressure and the refrigerant temperature are determined using a map. The heating up phase for the vehicle interior is increased and an entry is made in the event memory.The refrigerant pressure and temperature sensors can only be replaced after the refrigerant has been extracted.17ComponentsCoolant Change-Over Valve 1 N632Location The Coolant Change-Over Valve 1 is located in the coolant circuit.Design The Coolant Change-Over Valve 1 is a 3/2-way valve.Z1 1 5AX4 N632JX1Function This valve is used to switch between the large coolant circuit and the small coolant circuit with the high voltage heater (PTC). When not powered, it is constantly open and only the large coolant circuit is active. The heat-up phase of the vehicle interior takes longer.s532_092To High-voltage Heater (PTC) Z1 1 5s532_027From the Power and Control Electronics for Electric Drive JX1To the Charging Unit 1 for High-voltage Battery AX418ComponentsThermal Management Control Module J1024Location This control module is located in the engine compartment under the 12 V battery. It is connected to the Data-Bus On-Board Diagnostic Interface J533 via the Extended CAN-Bus.Function The Thermal Management Control Module J1024 takes care of all functions that are associated with controlling the refrigerant circuit.s532_051Failure Effects If the Thermal Management Control Module J1094 fails, the entire air conditioning system will not operate.19Functions of the Heat PumpHeating Function in Air ModeElectrical Air Conditioner CompressorSV4 SV5 SV1 EV1 Heat CondenserEvaporator Condenser s532_014EV2EV3Key EV SV Expansion valve Shut-off valve High-pressure area Mid-pressure area Low-pressure areaThis function uses only the heat from the outside air to heat the vehicle interior. 1 . The electrical air conditioner compressor compresses the refrigerant. The gaseous refrigerant is under high pressure at a high temperature. 2. In the heat condenser, the refrigerant transfers heat to the air and starts to condense. The heated air flows as heating air into the vehicle interior. 3. Cut-off valves 1 and 4 are closed. The pressure is reduced via Expansion Valve 1 . The temperature of the liquid refrigerant decreases. 4. The evaporator now works as a condenser. The incoming refrigerant condenses and releases heat. The now pre-heated air flows to the heat condenser. 5. Expansion Valve 3 is closed. The refrigerant pressure is lowered further via Expansion Valve 2. The refrigerant temperature now falls below the ambient temperature. 6. The cold refrigerant, which is below ambient temperature, evaporates in the condenser. The heat of vaporization required for this process is drawn from the warmer outside air, which then cools down. The gaseous refrigerant leaves the condenser and flows through the open Cut-off Valve 5 in the direction of the air conditioner compressor.20Functions of the Heat PumpPhase Diagram of the R134a RefrigerantThis diagram shows the state of the R134a refrigerant during the heating function (air mode).Pressure [bar]Energy Content (kJ/kg)Explanation A - B: compression (electrical air conditioner compressor) The refrigerant is gaseous; the pressure and the temperature rise. B - C: condensation (heat condenser) The refrigerant turns into liquid, the temperature falls and the pressure remains constant. C - D: expansion (Expansion Valve 1) The pressure is relieved via Expansion Valve 1 . This leads to partial evaporation of the refrigerant and the temperature falls. D - E: condensation (evaporator) The refrigerant condenses, the temperature falls and the pressure remains constant. E - F: expansion (Expansion Valve 2) The pressure is relieved via Expansion Valve 2. The temperature falls below the ambient temperature. F - A: evaporation (condenser) The refrigerant becomes completely gaseous, the temperature and the pressure remain constant. K: critical point The boiling line of the refrigerant is to the left of the critical point and the saturated vapor line is to the right of it.21Functions of the Heat PumpHeating Function in Coolant ModeRefrigerant Circuit with Large Coolant CircuitElectrical Air Conditioner CompressorSV5SV4EV1Section of Small Coolant CircuitSV1 Heat Exchanger for Heat Condenser Evaporator Z1 1 5EV2 Condenser EV3 Heat CondenserV509s532_050Z1 1 5KeyV509 N632 VX54 JX1 V508 AX4EV Expansion Valve SV Cut-off valve AX4 High Voltage Battery Charger 1 JX1 Electric Drive Power and Control Electronics N632 Coolant Change-Over Valve 1 N687 Radiator Bypass Switch-Over Valve V508 Coolant Pump in Front of Electric Drive and Power Control Electronics V509 Coolant Pump In Front of High Voltage Heater (PTC)N687s532_048VX54 Three-phase Current Drive Z115 High Voltage Heater (PTC) High-pressure Area Mid-pressure Area Low-pressure Area Coolant Refrigerant Circuit Coolant Circuit22Functions of the Heat PumpRefrigerant CircuitThis function uses the thermal energy from the coolant circuit (three-phase current drive, power and control electronics and battery charging module). 1 . - 4. The compressor compression and condensation in the evaporator is identical to the heating function in air mode. 5. Expansion Valve 2 is closed. The pressure is relieved by Expansion Valve 3 and the temperature of the liquid refrigerant decreases. 6. The refrigerant evaporates in the Heat Exchanger for Heat Condenser due to the addition of heat. The heat of vaporization required for this process is drawn from the warmer coolant, which then cools down. The gaseous refrigerant leaves the heat exchanger for heat condenser and flows in the direction of the air conditioner compressor.Large Coolant Circuit The coolant flows through the large coolant circuit to pull heat from the heat from the three-phase current drive, the power and control electronics and the battery charging unit. This circuit is run by the Coolant Pump in Front of Electric Drive Power and Control Electronics V508. The radiator is bypassed by actuating the Radiator Bypass Switchover Valve N687 to use heat efficiently.Small Coolant Circuit If the evaporation output of the large coolant circuit and the air is not sufficient, additional energy is supplied to the coolant circuit and the coolant is heated by activating the High Voltage Heater (PTC). To prevent the three-phase current drive, the power and control electronics for electric drive and the battery charging unit from heating up, the large coolant circuit is isolated from the small coolant circuit by actuating the Coolant Change-Over Valve 1 N632. The small coolant circuit is operated by activating the Coolant Pump in Front of the High Voltage Heater (PTC).23Functions of the Heat PumpHeating Function in Combined Air and Coolant ModeElectrical Air Conditioner CompressorSV4 SV5 SV1 EV1 Heat CondenserEvaporator Condensers532_020Heat Exchanger for Heat CondenserEV2 EV3Key EV Expansion valve SV Cut-off valve High-pressure area Mid-pressure area Low-pressure areaThis function is a combination of the two functions described above. Heat from the outside air and the heat from the coolant are used simultaneously to heat the vehicle interior. 1 . - 4. The process from compression in the electrical air conditioner compressor to complete condensation in the evaporator is identical to the heating function in air mode. 5. Expansion Valves 2 and 3 reduce the pressure. As a result, the temperature of the liquid refrigerant drops. After expansion, the refrigerant temperature is lower than the ambient temperature. The heat pump control module regulates how much refrigerant flows through each of the two expansion valves. 6. The cold refrigerant, which is below ambient temperature, evaporates in the condenser. The heat of vaporization required for this process is drawn from the warmer outside air, which then cools. The gaseous refrigerant leaves the evaporator and flows through the open Cut-off Valve 5 in the direction of the air conditioner compressor. 7 . The refrigerant evaporates in the Heat Exchanger for Heat Condenser due to the addition of heat. The heat of vaporization required for this process is drawn from the warmer coolant. The gaseous refrigerant leaves the Heat Exchanger for Heat Condenser and flows in the direction of the air conditioner compressor.24Functions of the Heat PumpCooling FunctionElectrical Air Conditioner CompressorSV4 SV5 SV1 EV1 Heat Condenser Heating FlapEvaporator Condensers532_022EV2EV3Key EV Expansion valve SV Cut-off valve High-pressure area Low-pressure areaIn this function, the heat pump circuit uses cold temperatures to cool the vehicle interior. 1 . The electrical air conditioner compressor compresses the refrigerant. The gaseous refrigerant is under high pressure at a high temperature. 2. Cool air does not flow through the heat condenser since the heating flap is closed. The refrigerant does not condense here and also does not release any heat. 3. Expansion Valve 1 closes the access to the evaporator. The refrigerant flows through the open Cut-off Valve 1 to the condenser. 4. The airflow passes through the condenser. The refrigerant transfers heat to the air and condenses. The temperature of the refrigerant falls, the pressure remains constant. 5. The pressure and the temperature of the liquid refrigerant are reduced via Expansion Valve 2. After expansion, the refrigerant temperature is lower than the ambient temperature. 6. The refrigerant evaporates completely in the evaporator. The heat of vaporization required for this process is drawn from the outside air, which then cools down. The cooled air flows into the vehicle interior. 7 . The gaseous refrigerant leaves the evaporator and flows through the open Cut-off Valve 4 in the direction of the air conditioner compressor.25System OverviewSensorsDiagnostic Connection Climatronic Control Module J255 Data-Bus On-Board Diagnostic Interface J533 Convenience CANBus A/C Engine Coolant Temperature Sensor G1 10 Refrigerant Expansion Valve 2 N637 A/C Pressure/Temperature Sensor G395 CAN-Bus Extended Refrigerant Expansion Valve 3 N638 Refrigerant Expansion Valve 1 N636ActuatorsA/C Pressure/Temperature Sensor 2 G826A/C Pressure/Temperature Sensor 3 G827Refrigerant Cut-off Valve 1 N696A/C Pressure/Temperature Sensor 4 G828Refrigerant Cut-off Valve 4 N642A/C Pressure/Temperature Sensor 5 G829 Thermal Management Control Module J1024Refrigerant Cut-off Valve 5 N643Electrical A/C Compressor V470LIN-BusCoolant Change-Over Valve 1 N632s532_038High Voltage Heater (PTC) Z1 1 526ServiceThe heat pump system is maintenance-free. The repair manual must be followed when emptying and filling the system. There are no special tools. Only persons qualified to work on air conditioning systems may perform work on the heat pump system. Before beginning servicing work on the heat pump system, please observe the repair manual information about any procedures that require de-energization by a High-Voltage Technician (HVT).27Important Linkshttps://www.datarunners.net/vw_crc/default.asp?pageid=homewww.vwwebsource.comwww.vwhub.comKnowledge AssessmentAn on-line Knowledge Assessment (exam) is available for this Self-Study Program. The Knowledge Assessment may or may not be required for Certification. You can find this Knowledge Assessment at: www.vwwebsource.comFor Assistance, please call: Volkswagen Academy Certification Program Headquarters 1-877-791-4838 (8:00 a.m. to 8:00 p.m. EST)Or, E-mail: concierge@volkswagenacademy.com29Volkswagen Group of America 2200 Ferdinand Porsche Drive Herndon, VA 20171 July 2015